TY - JOUR A1 - Bier, Frank Fabian A1 - Ehrentreich-Förster, Eva A1 - Scheller, Frieder W. A1 - Makower, Alexander A1 - Eremenko, A. V. A1 - Wollenberger, Ursula A1 - Bauer, Christian G. A1 - Pfeiffer, Dorothea A1 - Micheel, Burkhard T1 - Ultrasensitive biosensors Y1 - 1996 ER - TY - JOUR A1 - Ghindilis, A. L. A1 - Makower, Alexander A1 - Bauer, Christian G. A1 - Bier, Frank Fabian A1 - Scheller, Frieder W. T1 - Determination of p-aminophenol and catecholamines at picomolar concentrations based on recycling enzyme amplification Y1 - 1995 ER - TY - JOUR A1 - Scheller, Frieder W. A1 - Makower, Alexander A1 - Bier, Frank Fabian A1 - Wollenberger, Ursula A1 - Ghindilis, A. L. A1 - Eremenko, A. V. A1 - Pfeiffer, Dorothea T1 - Enzymsensoren zur Bestimmung subnanomolarer Konzentrationen Y1 - 1995 ER - TY - JOUR A1 - Bier, Frank Fabian A1 - Ehrentreich-Förster, Eva A1 - Makower, Alexander A1 - Scheller, Frieder W. T1 - An enzymatic amplification cycle for high sensitive immunoassay Y1 - 1996 ER - TY - JOUR A1 - Song, Min Ik A1 - Bier, Frank Fabian A1 - Scheller, Frieder W. T1 - A method to detect superoxide radicals using teflon membrane and superoxide dismutase Y1 - 1995 ER - TY - JOUR A1 - Scheller, Frieder W. A1 - Bier, Frank Fabian A1 - Pfeiffer, Dorothea T1 - Biosensoren : Grundlagen und Anwendungen Y1 - 1995 ER - TY - JOUR A1 - Scheller, Frieder W. A1 - Makower, Alexander A1 - Ghindilis, A. L. A1 - Bier, Frank Fabian A1 - Ehrentreich-Förster, Eva A1 - Wollenberger, Ursula A1 - Bauer, Christian G. A1 - Micheel, Burkhard A1 - Pfeiffer, Dorothea A1 - Szeponik, Jan A1 - Michael, N. A1 - Kaden, H. T1 - Enzyme sensors for subnanomolar concentrations Y1 - 1995 ER - TY - JOUR A1 - Jin, Wen A1 - Wollenberger, Ursula A1 - Bier, Frank Fabian A1 - Scheller, Frieder W. T1 - Construction and characterization of multi-layer-enzyme electrode : covalent binding of quinoprotein glucose dehydrogenase onto gold electrodes Y1 - 1995 ER - TY - GEN A1 - Bier, Frank Fabian A1 - Yin, Wen A1 - Kleinjung, Frank A1 - Scheller, Frieder W. T1 - Molekulare Schichten zur Analyse biochemischer Bindungen und Umsatzreaktionen Y1 - 1995 ER - TY - JOUR A1 - Kleinjung, Frank A1 - Bier, Frank Fabian A1 - Scheller, Frieder W. T1 - Messungen an Nukleinsäuren mittels evaneszenten Feldes Y1 - 1995 ER - TY - JOUR A1 - Bier, Frank Fabian A1 - Scheller, Frieder W. A1 - Klingbeil, Mandy A1 - Oßwald, U. T1 - Biosensoren und Teststreifen für die Umwelt- und Lebensmittelanalytik : eine Übersicht Y1 - 1993 ER - TY - JOUR A1 - Scheller, Frieder W. A1 - Bier, Frank Fabian A1 - Neumann, B. T1 - Bioindikation in aquatischen Ökosystemen : Bioindikation in limnischen und küstennahen Ökosystemen ; Grundlagen, Verfahren und Methoden Y1 - 1994 PB - Fischer CY - Jena ER - TY - JOUR A1 - Dechtrirat, Decha A1 - Gajovic-Eichelmann, Nenad A1 - Wojcik, Felix A1 - Hartmann, Laura A1 - Bier, Frank Fabian A1 - Scheller, Frieder W. T1 - Electrochemical displacement sensor based on ferrocene boronic acid tracer and immobilized glycan for saccharide binding proteins and E. coli JF - Biosensors and bioelectronics : the principal international journal devoted to research, design development and application of biosensors and bioelectronics N2 - Pathogens such as viruses and bacteria use their envelope proteins and their adhesin lectins to recognize the glycan residues presented on the cell surface of the target tissues. This principle of recognition is used in a new electrochemical displacement sensor for the protein concanavalin A (ConA). A gold electrode was first modified with a self-assembled monolayer of a thiolated mannose/OEG conjugate and a ferrocene boroxol derivative was pre-assembled as reporter molecule onto the mannose surface. The novel tracer molecule based on a 2-hydroxymethyl phenyl boronic acid derivative binds even at neutral pH to the saccharides which could expand the application towards biological samples (i.e., urine and feces). Upon the binding of ConA, the tracer was displaced and washed away from the sensor surface leading to a decrease in the electrochemical signal. Using square wave voltammetry (SWV), the concentration of ConA in the sample solution could be determined in the dynamic concentration range established from 38 nmol L-1 to 5.76 mu mol L-1 with a reproducible detection limit of 1 mu g mL(-1) (38 nmol L-1) based on the signal-to-noise ratio (S/N=3) with fast response of 15 min. The new reporter molecule showed a reduced non-specific displacement by BSA and ribonuclease A. The sensor was also successfully transferred to the first proof of principle for the detection of Escherichia coli exhibiting a detection limit of approximately 6 x 102 cells/mL Specificity of the displacement by target protein ConA and E. coli was demonstrated since the control proteins (i.e., BSA and RNaseA) and the control E. coli strain, which lack of type 1 fimbriae, were ineffective. (C) 2014 Elsevier B.V. All rights reserved. KW - Ferrocene benzoboroxol biosensor KW - Concanavalin A KW - Displacement KW - Escherichia coli KW - Ferrocene boronic acid KW - Self-assembled monolayer Y1 - 2014 U6 - https://doi.org/10.1016/j.bios.2014.02.028 SN - 0956-5663 SN - 1873-4235 VL - 58 SP - 1 EP - 8 PB - Elsevier CY - Oxford ER - TY - JOUR A1 - Scheller, Frieder W. A1 - Yarman, Aysu A1 - Bachmann, Till A1 - Hirsch, Thomas A1 - Kubick, Stefan A1 - Renneberg, Reinhard A1 - Schumacher, Soeren A1 - Wollenberger, Ursula A1 - Teller, Carsten A1 - Bier, Frank Fabian ED - Gu, MB ED - Kim, HS T1 - Future of biosensors: a personal view JF - Advances in biochemical engineering, biotechnology JF - Advances in Biochemical Engineering-Biotechnology N2 - Biosensors representing the technological counterpart of living senses have found routine application in amperometric enzyme electrodes for decentralized blood glucose measurement, interaction analysis by surface plasmon resonance in drug development, and to some extent DNA chips for expression analysis and enzyme polymorphisms. These technologies have already reached a highly advanced level and need minor improvement at most. The dream of the "100-dollar' personal genome may come true in the next few years provided that the technological hurdles of nanopore technology or of polymerase-based single molecule sequencing can be overcome. Tailor-made recognition elements for biosensors including membrane-bound enzymes and receptors will be prepared by cell-free protein synthesis. As alternatives for biological recognition elements, molecularly imprinted polymers (MIPs) have been created. They have the potential to substitute antibodies in biosensors and biochips for the measurement of low-molecular-weight substances, proteins, viruses, and living cells. They are more stable than proteins and can be produced in large amounts by chemical synthesis. Integration of nanomaterials, especially of graphene, could lead to new miniaturized biosensors with high sensitivity and ultrafast response. In the future individual therapy will include genetic profiling of isoenzymes and polymorphic forms of drug-metabolizing enzymes especially of the cytochrome P450 family. For defining the pharmacokinetics including the clearance of a given genotype enzyme electrodes will be a useful tool. For decentralized online patient control or the integration into everyday "consumables' such as drinking water, foods, hygienic articles, clothing, or for control of air conditioners in buildings and cars and swimming pools, a new generation of "autonomous' biosensors will emerge. KW - Biosensors KW - Molecularly imprinted polymers KW - Personalized medicine Y1 - 2014 SN - 978-3-642-54143-8; 978-3-642-54142-1 U6 - https://doi.org/10.1007/10_2013_251 SN - 0724-6145 VL - 140 SP - 1 EP - 28 PB - Springer CY - Berlin ER - TY - JOUR A1 - Stöcklein, Walter F. M. A1 - Warsinke, Axel A1 - Scheller, Frieder W. T1 - Organic solvent modified enzyme-liked immunoassay for the detection of triazine herbicides Y1 - 1997 ER - TY - JOUR A1 - Scheller, Frieder W. A1 - Schubert, Frank A1 - Federowitz, J. T1 - Present state and frontiers in biosensorics Y1 - 1997 ER - TY - JOUR A1 - Stöcklein, Walter F. M. A1 - Scheller, Frieder W. T1 - Enzymes and antibodies in organic media : analytical applications Y1 - 1997 ER - TY - JOUR A1 - Wollenberger, Ursula A1 - Lisdat, Fred A1 - Scheller, Frieder W. T1 - Enzymatic substrade recycling electrodes Y1 - 1997 ER - TY - JOUR A1 - Eremenko, A. V. A1 - Makower, Alexander A1 - Bauer, Christian G. A1 - Kurochkin, I. N. A1 - Scheller, Frieder W. T1 - A bienzyme electrode for tyrosine containing peptides determination Y1 - 1997 ER - TY - JOUR A1 - Xie, B. A1 - Tang, X. A1 - Wollenberger, Ursula A1 - Johansson, G. A1 - Gorton, Lo A1 - Scheller, Frieder W. A1 - Danielsson, B. T1 - Hybrid biosensor for simultaneous electrochemical and thermal detection Y1 - 1997 ER -