TY - JOUR A1 - Nagel, Birgit A1 - Warsinke, Axel T1 - Towards separation-free electrochemical affinity sensors by using antibodies, aptamers and molecularly imprinted polymers : a review Y1 - 2006 U6 - https://doi.org/10.1080/00032710600853903 ER - TY - JOUR A1 - Lettau, Kristian A1 - Warsinke, Axel A1 - Katterle, Martin A1 - Danielsson, Bengt A1 - Scheller, Frieder W. T1 - A bifunctional molecularly imprinted polymer (MIP): analysis of binding and catalysis by a thermistor N2 - Binding or catalysis? Both can be distinguished with a molecularly imprinted polymer (MIP) by the different patterns of heat generation. The catalytically active sites, like in the corresponding enzyme, generate a steady-state temperature increase. Thus, enzyme-like catalysis and antibody-analogue binding are analyzed simultaneously in a bifunctional MIP for the first time (see scheme). Y1 - 2006 UR - http://www3.interscience.wiley.com/cgi-bin/jhome/26737/ U6 - https://doi.org/10.1002/anie.200601796 ER - TY - JOUR A1 - Liu, Songqin A1 - Wollenberger, Ursula A1 - Halamek, Jan A1 - Leupold, Eik A1 - Stöcklein, Walter F. M. A1 - Warsinke, Axel A1 - Scheller, Frieder W. T1 - Affinity interaction betwen phenylboronic acid-carrying self-assembled monolayers and FAD or HRP N2 - A method is provided for the recognition of glycated molecules based on their binding affinities to boronate- carrying monolayers. The affinity interaction of flavin adenine dinucleotide (FAD) and horseradish peroxidase (HRP) with phenylboronic acid monolayers on gold was investigated by using voltammetric and microgravimetric methods. Conjugates of 3-aminopherrylboronic acid and 3,3'-dithiodipropionic acid di(N-hydroxysuccinimide ester) or 11-mercaptoundecanoic acid were prepared and self-assembled on gold surfaces to generate monolayers. FAD is bound to this modified sur-face and recognized by a pair of redox peaks with a formal potential of -0.433 V in a 0.1 m phosphate buffer solution, pH 6.5. Upon addition of a sugar to the buffer, the bound FAD could be replaced, indicating that the binding is reversible. Voltammetric, mass measurements, and photometric activity assays show that the HRP can also be bound to the interface. This binding is reversible, and HRP can be replaced by sorbitol or removed in acidic solution. The effects of pH, incubation time, and concentration of H2O2 were studied by comparing the catalytic reduction of H2O2 in the presence of the electron-donor thionine. The catalytic current of the HRP-loaded electrode was proportional to HRP concentrations in the incubation solution in the range between 5 mu g mL(-1) and 0.4 mg mL(-1) with a linear slope of 3.34 mu A mL mg(-1) and a correlation coefficient of 0.9945 Y1 - 2005 ER - TY - JOUR A1 - Mak, Wing Cheung A1 - Cheung, Kwan Yee A1 - Trau, Dieter A1 - Warsinke, Axel A1 - Scheller, Frieder W. A1 - Renneberg, Reinhard T1 - Electrochemical bioassay utilizing encapsulated electrochemical active microcrystal biolabels N2 - A new approach to perform electrochemical immunoassay based on the utilization of encapsulated microcrystal was developed. The microcrystal labels create a "supernova effect" upon exposure to a desired releasing agent. The microcrystal cores dissolve, and large amounts of signal-generating molecules diffuse across the capsule wall into the outer environment. Layer-by-Layer (LbL) technology was employed for the encapsulation of electrochemical signal- generating microcrystals (ferrocene microcrystals). The encapsulated microcrystals were conjugated with antibody molecules through the adsorption process. The biofunctionalized microcrystals were utilized as a probe for immunoassays. The microcrystal-based label system provided a high-signal molecule to antibody (SIP) ratio of 10(4)-10(5). Microcrystal biolabels with different antibody surface coverage (1.60-5.05 mg m(-2)) were subjected to a solid-phase immunoassay for the detection of mouse immunoglobulin G (M-IgG) molecules. The microcrystal-based immunoassay for the detection of M-IgG performed with microcrystals having antibody surface coverage of 5.05 mg m(-2) showed a sensitivity of 3.93 nA g(- 1) L-1 with a detection limit of 2.82 g L-1 Y1 - 2005 SN - 0003-2700 ER - TY - JOUR A1 - Lettau, Kristian A1 - Warsinke, Axel A1 - Laschewsky, André A1 - Mosbach, K. A1 - Yilmaz, E. A1 - Scheller, Frieder W. T1 - An esterolytic imprinted polymer prepared via a silica-supported transition state analogue N2 - In this work we describe a new preparation method for an esterolytic imprinted polymer with catalytic sites on the surface. A template was prepared by immobilizing a transition state analogue (phosphoramidic acid derivative) of an esterolytic reaction within porous silica particles. Polymerization within the pores was carried out using 4- vinylimidazole as a functional monomer and divinylbenzene as a cross-linker. The polymer was released by dissolution of the silica support with hydrofluoric acid and catalytic properties were studied by incubation with three different 4- nitrophenylesters and spectrophotometric determination of the released 4-nitrophenol. For 4-nitrophenyl acetate an activity of 211 nmol min(-1) mg(-1) and a K-m value of 2.2 mmol L-1 was obtained Y1 - 2004 ER - TY - JOUR A1 - Pieper-Fürst, U. A1 - Kleuser, U. A1 - Stöcklein, Walter F. M. A1 - Warsinke, Axel A1 - Scheller, Frieder W. T1 - Detection of subicomolar concentrations of human matrix metalloproteinase-2 by an optical biosensor N2 - We describe in this paper the development of a one-step sandwich assay for the highly sensitive and fast detection of human matrix metalloproteinase (MMP)-2 (EC 3.4.24.24), using surface plasmon resonance (SPR). For the assay, two ligands were selected: monoclonal anti-MMP-2 antibody Ab-2 and the tissue inhibitor of metalloproteinases (TIMP)-2. They were chosen on the basis of (1) their affinities to MMP-2, (2) the efficiency of immobilization to the sensor chip, (3) the efficiency of adsorption to colloidal gold, and (4) the stability of these protein-coated gold particles. The assay included mixing of MMP-2 with antibody Ab-2 adsorbed to colloidal gold with a diameter of about 20 rim and injection into the flowcell of the SPR instrument containing immobilized TIMP-2. By using colloidal gold particles an amplification factor of 114 and a detection limit of 0.5 pM for MMP-2 were obtained. The precision of the assay was high even at low analyte concentrations, the standard deviation being 8.3% for five determinations of 1 pM MMP- 2. No significant binding was observed with the structurally related MMP-9. The assay is far more sensitive and faster than commonly used methods for MMP-2 detection. As TIMP-bound MMP-2 is not detected by this method, the assay can be applied for measuring free MMP-2, reflecting the imbalance of free and inhibitor-bound enzyme in various pathological situations. (C) 2004 Elsevier Inc. All rights reserved Y1 - 2004 ER - TY - JOUR A1 - Stoellner, Daniela A1 - Scheller, Frieder W. A1 - Warsinke, Axel T1 - Activation of cellulose membranes with 1,1ï-carbonyldiimidazole or 1-cyano-4-4-dimethylaminopyridinium tetrafluoroborate as a basis for the development of immunosensors Y1 - 2002 ER - TY - JOUR A1 - Stöcklein, Walter F. M. A1 - Warsinke, Axel A1 - Scheller, Frieder W. T1 - Organic solvent modified enzyme-liked immunoassay for the detection of triazine herbicides Y1 - 1997 ER - TY - JOUR A1 - Warsinke, Axel T1 - Biosensors for food analysis Y1 - 1997 ER - TY - JOUR A1 - Gajovic, Nenad A1 - Warsinke, Axel A1 - Scheller, Frieder W. T1 - Comparsion of two enzyme sequences for a novel L-malate biosensor Y1 - 1997 ER -