TY - GEN A1 - Cywiński, Piotr J. A1 - Nono, Katia Nchimi A1 - Charbonnière, Loïc J. A1 - Hammann, Tommy A1 - Löhmannsröben, Hans-Gerd T1 - Photophysical evaluation of a new functional terbium complex in FRET-based time-resolved homogenous fluoroassays N2 - A new functional luminescent lanthanide complex (LLC) has been synthesized with terbium as a central lanthanide ion and biotin as a functional moiety. Unlike in typical lanthanide complexes assembled via carboxylic moieties, in the presented complex, four phosphate groups are chelating the central lanthanide ion. This special chemical assembly enhances the complex stability in phosphate buffers conventionally used in biochemistry. The complex synthesis strategy and photophysical properties are described as well as the performance in time-resolved Förster Resonance Energy Transfer (FRET) assays. In those assays, this biotin-LLC transferred energy either to acceptor organic dyes (Cy5 or AF680) labelled on streptavidin or to quantum dots (QD655 or QD705) surface-functionalised with streptavidins. The permanent spatial donor–acceptor proximity is assured through strong and stable biotin–streptavidin binding. The energy transfer is evidenced from the quenching observed in donor emission and from a decrease in donor luminescence decay, both associated with simultaneous increase in acceptor intensity and in the decay time. The dye-based assays are realised in TRIS and in PBS, whereas QD-based systems are studied in borate buffer. The delayed emission analysis allows for quantifying the recognition process and for auto-fluorescence-free detection, which is particularly relevant for application in bioanalysis. In accordance with Förster theory, Förster-radii (R0) were found to be around 60 Å for organic dyes and around 105 Å for QDs. The FRET efficiency (η) reached 80% and 25% for dye and QD acceptors, respectively. Physical donor–acceptor distances (r) have been determined in the range 45–60 Å for organic dye acceptors, while for acceptor QDs between 120 Å and 145 Å. This newly synthesised biotin-LLC extends the class of highly sensitive analytical tools to be applied in the bioanalytical methods such as time-resolved fluoroimmunoassays (TR-FIA), luminescent imaging and biosensing. T3 - Zweitveröffentlichungen der Universität Potsdam : Mathematisch-Naturwissenschaftliche Reihe - 252 KW - acceptors KW - bioanalysis KW - contrast agents KW - europium KW - fluoroimmunoassay KW - labels KW - lanthanide luminescence KW - quantum dots KW - resonance energy-transfer Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-95390 SP - 6060 EP - 6067 ER - TY - JOUR A1 - Hildebrandt, Niko A1 - Charbonniere, Loïc J. A1 - Beck, Michael A1 - Ziessel, Raymond F. A1 - Löhmannsröben, Hans-Gerd T1 - Quantum dots as efficient energy acceptors in a time-resolved fluoroimmunoassay Y1 - 2005 SN - 1433-7851 ER - TY - GEN A1 - Hildebrandt, Nico A1 - Charbonnière, Loïc J. A1 - Ziessel, Raymond F. A1 - Löhmannsröben, Hans-Gerd T1 - Quantum dots as resonance energy transfer acceptors for monitoring biological interactions N2 - Quantum dots (QDs) are common as luminescing markers for imaging in biological applications because their optical properties seem to be inert against their surrounding solvent. This, together with broad and strong absorption bands and intense, sharp tuneable luminescence bands, makes them interesting candidates for methods utilizing Forster Resonance Energy Transfer (FRET), e. g. for sensitive homogeneous fluoroimmunoassays (FIA). In this work we demonstrate energy transfer from Eu3+-trisbipyridin (Eu-TBP) donors to CdSe-ZnS-QD acceptors in solutions with and without serum. The QDs are commercially available CdSe-ZnS core-shell particles emitting at 655 nm (QD655). The FRET system was achieved by the binding of the streptavidin conjugated donors with the biotin conjugated acceptors. After excitation of Eu-TBP and as result of the energy transfer, the luminescence of the QD655 acceptors also showed lengthened decay times like the donors. The energy transfer efficiency, as calculated from the decay times of the bound and the unbound components, amounted to 37%. The Forster-radius, estimated from the absorption and emission bands, was ca. 77Å. The effective binding ratio, which not only depends on the ratio of binding pairs but also on unspecific binding, was obtained from the donor emission dependent on the concentration. As serum promotes unspecific binding, the overall FRET efficiency of the assay was reduced. We conclude that QDs are good substitutes for acceptors in FRET if combined with slow decay donors like Europium. The investigation of the influence of the serum provides guidance towards improving binding properties of QD assays. T3 - Zweitveröffentlichungen der Universität Potsdam : Mathematisch-Naturwissenschaftliche Reihe - paper 012 Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus-12213 ER - TY - JOUR A1 - Geißler, Daniel A1 - Charbonnière, Loïc J. A1 - Ziessel, Raymond F. A1 - Butlin, Nathaniel G. A1 - Löhmannsröben, Hans-Gerd A1 - Hildebrandt, Niko T1 - Quantum dot biosensors for ultrasensitive multiplexed diagnostics N2 - Time- and color-resolved detection of Foerster resonance energy transfer (FRET) from luminescent terbium complexes to different semiconductor quantum dots results in a fivefold multiplexed bioassay with sub-picomolar detection limits for all five bioanalytes (see picture). The detection of up to five biomarkers occurs with a sensitivity that is 40-240-fold higher than one of the best-established single-analyte reference assays. Y1 - 2010 UR - http://www3.interscience.wiley.com/cgi-bin/jhome/26737/ U6 - https://doi.org/10.1002/anie.200906399 SN - 1433-7851 ER - TY - JOUR A1 - Charbonnière, Loic J. A1 - Hildebrandt, Niko T1 - Lanthanide complexes and quantum dots : a bright wedding for resonance energy transfer N2 - In this microreview we describe the principle of Forster resonance energy transfer (FRET) occurring between closely spaced energy-donor and -acceptor molecules. The theoretical treatment is depicted in relation with the data extractable from spectroscopic measurements. We present the specific case of semiconductor nanocrystals (or quantum dots QDs) as energy donors in FRET experiments and a particular emphasis is put on the specific advantages of these fluorophores with regard to both their exceptional photophysical properties and their nanoscopic morphology. In a following section, the special attributes of luminescent lanthanide complexes (LLCs) are outlined with illustrations of properties such as their characteristic emission spectra, long-lived luminescence, and large "Stokes shift". Finally, the successful combination of LLCs and QDs in FRET experiments is demonstrated, showing the unrivaled benefits of this singular marriage, opening doors for energy transfer at very large distances and excellent sensitivity of detection within the frame of time-resolved fluoroimmunoassays. ((C) Wiley-VCH Verlag GmbH & Co. KGaA, 69451 Weinheim, Germany, 2008). Y1 - 2008 ER - TY - JOUR A1 - Kadjane, Pascal A1 - Starck, Matthieu A1 - Camerel, Franck A1 - Hill, Diana A1 - Hildebrandt, Niko A1 - Ziessel, Raymond A1 - Charbonnière, Loïc J. T1 - Divergent approach to a large variety of versatile luminescent lanthanide complexes N2 - Using a regioselective strategy for nucleophilic aromatic substitution on polyfluoropyridines, a nonacoordinating precursor was designed that is adequately suited for complexation of lanthanide cations. Further functionalizations afforded numerous applications for near-IR emission, two-photon absorption spectroscopy, or the formation of luminescent gels. Y1 - 2009 UR - http://pubs.acs.org/journal/inocaj U6 - https://doi.org/10.1021/Ic9001169 SN - 0020-1669 ER - TY - JOUR A1 - Geißler, Daniel A1 - Charbonnière, Loïc J. A1 - Ziessel, Raymond F. A1 - Löhmannsröben, Hans-Gerd T1 - Quantum dots as FRET acceptors for highly sensitive multiplexing immunoassays Y1 - 2009 ER - TY - JOUR A1 - Cywinski, Piotr J. A1 - Nono, Katia Nchimi A1 - Charbonniere, Loic J. A1 - Hammann, Tommy A1 - Löhmannsröben, Hans-Gerd T1 - Photophysical evaluation of a new functional terbium complex in FRET-based time-resolved homogenous fluoroassays JF - Physical chemistry, chemical physics : a journal of European Chemical Societies N2 - A new functional luminescent lanthanide complex (LLC) has been synthesized with terbium as a central lanthanide ion and biotin as a functional moiety. Unlike in typical lanthanide complexes assembled via carboxylic moieties, in the presented complex, four phosphate groups are chelating the central lanthanide ion. This special chemical assembly enhances the complex stability in phosphate buffers conventionally used in biochemistry. The complex synthesis strategy and photophysical properties are described as well as the performance in time-resolved Forster Resonance Energy Transfer (FRET) assays. In those assays, this biotin-LLC transferred energy either to acceptor organic dyes (Cy5 or AF680) labelled on streptavidin or to quantum dots (QD655 or QD705) surfacefunctionalised with streptavidins. The permanent spatial donor-acceptor proximity is assured through strong and stable biotin-streptavidin binding. The energy transfer is evidenced from the quenching observed in donor emission and from a decrease in donor luminescence decay, both associated with simultaneous increase in acceptor intensity and in the decay time. The dye-based assays are realised in TRIS and in PBS, whereas QD-based systems are studied in borate buffer. The delayed emission analysis allows for quantifying the recognition process and for auto-fluorescence-free detection, which is particularly relevant for application in bioanalysis. In accordance with Forster theory, Forsterradii (R0) were found to be around 60 angstrom for organic dyes and around 105 angstrom for QDs. The FRET efficiency (Z) reached 80% and 25% for dye and QD acceptors, respectively. Physical donor-acceptor distances (r) have been determined in the range 45-60 angstrom for organic dye acceptors, while for acceptor QDs between 120 angstrom and 145 angstrom. This newly synthesised biotin-LLC extends the class of highly sensitive analytical tools to be applied in the bioanalytical methods such as time-resolved fluoroimmunoassays (TR-FIA), luminescent imaging and biosensing. Y1 - 2014 U6 - https://doi.org/10.1039/c3cp54883j SN - 1463-9076 SN - 1463-9084 VL - 16 IS - 13 SP - 6060 EP - 6067 PB - Royal Society of Chemistry CY - Cambridge ER - TY - JOUR A1 - Morgner, Frank A1 - Lecointre, Alexandre A1 - Charbonniere, Loic J. A1 - Löhmannsröben, Hans-Gerd T1 - Detecting free hemoglobin in blood plasma and serum with luminescent terbium complexes JF - Physical chemistry, chemical physics : a journal of European Chemical Societies N2 - Hemolysis, the rupturing of red blood cells, can result from numerous medical conditions (in vivo) or occur after collecting blood specimen or extracting plasma and serum out of whole blood (in vitro). In clinical laboratory practice, hemolysis can be a serious problem due to its potential to bias detection of various analytes or biomarkers. Here we present the first "mix-and-measure' method to assess the degree of hemolysis in biosamples using luminescence spectroscopy. Luminescent terbium complexes (LTC) were studied in the presence of free hemoglobin (Hb) as indicators for hemolysis in TRIS-buffer, and in fresh human plasma with absorption, excitation and emission measurements. Our findings indicate dynamic as well as resonance energy transfer (FRET) between the LTC and the porphyrin ligand of hemoglobin. This transfer leads to a decrease in luminescence intensity and decay time even at nanomolar hemoglobin concentrations either in buffer or plasma. Luminescent terbium complexes are very sensitive to free hemoglobin in buffer and blood plasma. Due to the instant change in luminescence properties of the LTC in presence of Hb it is possible to access the concentration of hemoglobin via spectroscopic methods without incubation time or further treatment of the sample thus enabling a rapid and sensitive detection of hemolysis in clinical diagnostics. Y1 - 2015 U6 - https://doi.org/10.1039/c4cp04206a SN - 1463-9076 SN - 1463-9084 VL - 17 IS - 3 SP - 1740 EP - 1745 PB - Royal Society of Chemistry CY - Cambridge ER - TY - GEN A1 - Morgner, Frank A1 - Lecointre, Alexandre A1 - Charbonnière, Loic J. A1 - Löhmannsröben, Hans-Gerd T1 - Detecting free hemoglobin in blood plasma and serum with luminescent terbium complexes N2 - Hemolysis, the rupturing of red blood cells, can result from numerous medical conditions (in vivo) or occur after collecting blood specimen or extracting plasma and serum out of whole blood (in vitro). In clinical laboratory practice, hemolysis can be a serious problem due to its potential to bias detection of various analytes or biomarkers. Here we present the first ‘‘mix-and-measure’’ method to assess the degree of hemolysis in biosamples using luminescence spectroscopy. Luminescent terbium complexes (LTC) were studied in the presence of free hemoglobin (Hb) as indicators for hemolysis in TRIS-buffer, and in fresh human plasma with absorption, excitation and emission measurements. Our findings indicate dynamic as well as resonance energy transfer (FRET) between the LTC and the porphyrin ligand of hemoglobin. This transfer leads to a decrease in luminescence intensity and decay time even at nanomolar hemoglobin concentrations either in buffer or plasma. Luminescent terbium complexes are very sensitive to free hemoglobin in buffer and blood plasma. Due to the instant change in luminescence properties of the LTC in presence of Hb it is possible to access the concentration of hemoglobin via spectroscopic methods without incubation time or further treatment of the sample thus enabling a rapid and sensitive detection of hemolysis in clinical diagnostics. T3 - Zweitveröffentlichungen der Universität Potsdam : Mathematisch-Naturwissenschaftliche Reihe - 288 Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-99485 ER -