TY - JOUR A1 - Oberg, H. A1 - Gladh, Jörgen A1 - Anniyev, Toyli A1 - Beye, Martin A1 - Coffee, Ryan A1 - Föhlisch, Alexander A1 - Katayama, T. A1 - Kaya, Sarp A1 - LaRue, Jerry A1 - Mogelhoj, Andreas A1 - Nordlund, Dennis A1 - Ogasawara, Hirohito A1 - Schlotter, William F. A1 - Sellberg, Jonas A. A1 - Sorgenfrei, Nomi A1 - Turner, Joshua J. A1 - Wolf, Martin A1 - Wurth, W. A1 - Ostrom, Henrik A1 - Nilsson, Anders A1 - Norskov, Jens K. A1 - Pettersson, Lars G. M. T1 - Optical laser-induced CO desorption from Ru(0001) monitored with a free-electron X-ray laser: DFT prediction and X-ray confirmation of a precursor state JF - Surface science N2 - We present density functional theory modeling of time-resolved optical pump/X-ray spectroscopic probe data of CO desorption from Ru(0001). The BEEF van der Waals functional predicts a weakly bound state as a precursor to desorption. The optical pump leads to a near-instantaneous (<100 fs) increase of the electronic temperature to nearly 7000 K. The temperature evolution and energy transfer between electrons, substrate phonons and adsorbate is described by the two-temperature model and found to equilibrate on a timescale of a few picoseconds to an elevated local temperature of similar to 2000K. Estimating the free energy based on the computed potential of mean force along the desorption path, we find an entropic barrier to desorption (and by time-reversal also to adsorption). This entropic barrier separates the chemisorbed and precursor states, and becomes significant at the elevated temperature of the experiment (similar to 1.4 eV at 2000 K). Experimental pump-probe X-ray absorption/X-ray emission spectroscopy indicates population of a precursor state to desorption upon laser-excitation of the system (Dell'Angela et al., 2013). Computing spectra along the desorption path confirms the picture of a weakly bound transient state arising from ultrafast heating of the metal substrate. (C) 2015 Elsevier B.V. All rights reserved. KW - CO desorption KW - Potential of mean force KW - Two-temperature model KW - Pump-probe KW - X-ray spectroscopy KW - Density functional theory Y1 - 2015 U6 - https://doi.org/10.1016/j.susc.2015.03.011 SN - 0039-6028 SN - 1879-2758 VL - 640 SP - 80 EP - 88 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Schreck, Simon A1 - Beye, Martin A1 - Sellberg, Jonas A. A1 - McQueen, Trevor A1 - Laksmono, Hartawan A1 - Kennedy, Brian A1 - Eckert, Sebastian A1 - Schlesinger, Daniel A1 - Nordlund, Dennis A1 - Ogasawara, Hirohito A1 - Sierra, Raymond G. A1 - Segtnan, Vegard H. A1 - Kubicek, Katharina A1 - Schlotter, William F. A1 - Dakovski, Georgi L. A1 - Moeller, Stefan P. A1 - Bergmann, Uwe A1 - Techert, Simone A1 - Pettersson, Lars G. M. A1 - Wernet, Philippe A1 - Bogan, Michael J. A1 - Harada, Yoshihisa A1 - Nilsson, Anders A1 - Föhlisch, Alexander T1 - Reabsorption of soft x-ray emission at high x-ray free-electron laserfluences JF - Physical review letters N2 - We report on oxygen K-edge soft x-ray emission spectroscopy from a liquid water jet at the Linac Coherent Light Source. We observe significant changes in the spectral content when tuning over a wide range of incident x-ray fluences. In addition the total emission yield decreases at high fluences. These modifications result from reabsorption of x-ray emission by valence-excited molecules generated by the Auger cascade. Our observations have major implications for future x-ray emission studies at intense x-ray sources. We highlight the importance of the x-ray pulse length with respect to the core-hole lifetime. Y1 - 2014 U6 - https://doi.org/10.1103/PhysRevLett.113.153002 SN - 0031-9007 SN - 1079-7114 VL - 113 IS - 15 PB - American Physical Society CY - College Park ER - TY - JOUR A1 - Kunnus, Kristjan A1 - Rajkovic, Ivan A1 - Schreck, Simon A1 - Quevedo, Wilson A1 - Eckert, Sebastian A1 - Beye, Martin A1 - Suljoti, Edlira A1 - Weniger, Christian A1 - Kalus, Christian A1 - Gruebel, Sebastian A1 - Scholz, Mirko A1 - Nordlund, Dennis A1 - Zhang, Wenkai A1 - Hartsock, Robert W. A1 - Gaffney, Kelly J. A1 - Schlotter, William F. A1 - Turner, Joshua J. A1 - Kennedy, Brian A1 - Hennies, Franz A1 - Techert, Simone A1 - Wernet, Philippe A1 - Föhlisch, Alexander T1 - A setup for resonant inelastic soft x-ray scattering on liquids at free electron laser light sources JF - Review of scientific instruments : a monthly journal devoted to scientific instruments, apparatus, and techniques N2 - We present a flexible and compact experimental setup that combines an in vacuum liquid jet with an x-ray emission spectrometer to enable static and femtosecond time-resolved resonant inelastic soft x-ray scattering (RIXS) measurements from liquids at free electron laser (FEL) light sources. We demonstrate the feasibility of this type of experiments with the measurements performed at the Linac Coherent Light Source FEL facility. At the FEL we observed changes in the RIXS spectra at high peak fluences which currently sets a limit to maximum attainable count rate at FELs. The setup presented here opens up new possibilities to study the structure and dynamics in liquids. Y1 - 2012 U6 - https://doi.org/10.1063/1.4772685 SN - 0034-6748 VL - 83 IS - 12 PB - American Institute of Physics CY - Melville ER - TY - JOUR A1 - Mitzner, Rolf A1 - Rehanek, Jens A1 - Kern, Jan A1 - Gul, Sheraz A1 - Hattne, Johan A1 - Taguchi, Taketo A1 - Alonso-Mori, Roberto A1 - Tran, Rosalie A1 - Weniger, Christian A1 - Schröder, Henning A1 - Quevedo, Wilson A1 - Laksmono, Hartawan A1 - Sierra, Raymond G. A1 - Han, Guangye A1 - Lassalle-Kaiser, Benedikt A1 - Koroidov, Sergey A1 - Kubicek, Katharina A1 - Schreck, Simon A1 - Kunnus, Kristjan A1 - Brzhezinskaya, Maria A1 - Firsov, Alexander A1 - Minitti, Michael P. A1 - Turner, Joshua J. A1 - Möller, Stefan A1 - Sauter, Nicholas K. A1 - Bogan, Michael J. A1 - Nordlund, Dennis A1 - Schlotter, William F. A1 - Messinger, Johannes A1 - Borovik, Andrew S. A1 - Techert, Simone A1 - de Groot, Frank M. F. A1 - Föhlisch, Alexander A1 - Erko, Alexei A1 - Bergmann, Uwe A1 - Yachandra, Vittal K. A1 - Wernet, Philippe A1 - Yano, Junko T1 - L-edge x-ray absorption spectroscopy of dilute systems relevant to metalloproteins using an X-ray free-electron laser JF - The journal of physical chemistry letters N2 - L-edge spectroscopy of 3d transition metals provides important electronic structure information and has been used in many fields. However, the use of this method for studying dilute aqueous systems, such as metalloenzymes, has not been prevalent because of severe radiation damage and the lack of suitable detection systems. Here we present spectra from a dilute Mn aqueous solution using a high-transmission zone-plate spectrometer at the Linac Coherent Light Source (LCLS). The spectrometer has been optimized for discriminating the Mn L-edge signal from the overwhelming 0 K-edge background that arises from water and protein itself, and the ultrashort LCLS X-ray pulses can outrun X-ray induced damage. We show that the deviations of the partial-fluorescence yield-detected spectra from the true absorption can be well modeled using the state-dependence of the fluorescence yield, and discuss implications for the application of our concept to biological samples. Y1 - 2013 U6 - https://doi.org/10.1021/jz401837f SN - 1948-7185 VL - 4 IS - 21 SP - 3641 EP - 3647 PB - American Chemical Society CY - Washington ER -