TY - JOUR A1 - Bhuvanesh, Thanga A1 - Saretia, Shivam A1 - Roch, Toralf A1 - Schöne, Anne-Christin A1 - Rottke, Falko O. A1 - Kratz, Karl A1 - Wang, Weiwei A1 - Ma, Nan A1 - Schulz, Burkhard A1 - Lendlein, Andreas T1 - Langmuir-Schaefer films of fibronectin as designed biointerfaces for culturing stem cells JF - Polymers for advanced technologies N2 - Glycoproteins adsorbing on an implant upon contact with body fluids can affect the biological response in vitro and in vivo, depending on the type and conformation of the adsorbed biomacromolecules. However, this process is poorly characterized and so far not controllable. Here, protein monolayers of high molecular cohesion with defined density are transferred onto polymeric substrates by the Langmuir-Schaefer (LS) technique and were compared with solution deposition (SO) method. It is hypothesized that on polydimethylsiloxane (PDMS), a substrate with poor cell adhesion capacity, the fibronectin (FN) layers generated by the LS and SO methods will differ in their organization, subsequently facilitating differential stem cell adhesion behavior. Indeed, atomic force microscopy visualization and immunofluorescence images indicated that organization of the FN layer immobilized on PDMS was uniform and homogeneous. In contrast, FN deposited by SO method was rather heterogeneous with appearance of structures resembling protein aggregates. Human mesenchymal stem cells showed reduced absolute numbers of adherent cells, and the vinculin expression seemed to be higher and more homogenously distributed after seeding on PDMS equipped with FN by LS in comparison with PDMS equipped with FN by SO. These divergent responses could be attributed to differences in the availability of adhesion molecule ligands such as the Arg-Gly-Asp (RGD) peptide sequence presented at the interface. The LS method allows to control the protein layer characteristics, including the thickness and the protein orientation or conformation, which can be harnessed to direct stem cell responses to defined outcomes, including migration and differentiation. Copyright (c) 2016 John Wiley & Sons, Ltd. KW - Langmuir-Schaefer method KW - protein adsorption KW - stem cell adhesion KW - cell culture KW - fibronectin Y1 - 2017 U6 - https://doi.org/10.1002/pat.3910 SN - 1042-7147 SN - 1099-1581 VL - 28 SP - 1305 EP - 1311 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Blocki, Anna A1 - Löwenberg, Candy A1 - Jiang, Yi A1 - Kratz, Karl A1 - Neffe, Axel T. A1 - Jung, Friedrich A1 - Lendlein, Andreas T1 - Response of encapsulated cells to a gelatin matrix with varied bulk and microenvironmental elastic properties JF - Polymers for advanced technologies N2 - Gelatin-based hydrogels offer various biochemical cues that support encapsulated cells and are therefore suitable as cell delivery vehicles in regenerative medicine. However, besides the biochemical signals, biomechanical cues are crucial to ensure an optimal support of encapsulated cells. Hence, we aimed to correlate the cellular response of encapsulated cells to macroscopic and microscopic elastic properties of glycidylmethacrylate (GMA)-functionalized gelatin-based hydrogels. To ensure that different observations in cellular behavior could be attributed to differences in elastic properties, an identical concentration as well as degree of functionalization of biopolymers was utilized to form covalently crosslinked hydrogels. Elastic properties were merely altered by varying the average gelatin-chain length. Hydrogels exhibited an increased degree of swelling and a decreased bulk elastic modulus G with prolonged autoclaving of the starting solution. This was accompanied by an increase of hydrogel mesh size and thus by a reduction of crosslinking density. Tougher hydrogels retained the largest amount of cells; however, they also interfered with cell viability. Softer gels contained a lower cell density, but supported cell elongation and viability. Observed differences could be partially attributed to differences in bulk properties, as high crosslinking densities interfere with diffusion and cell spreading and thus can impede cell viability. Interestingly, a microscopic elastic modulus in the range of native soft tissue supported cell viability and elongation best while ensuring a good cell entrapment. In conclusion, gelatin-based hydrogels providing a soft tissue-like microenvironment represent adequate cell delivery vehicles for tissue engineering approaches. Copyright (c) 2016 John Wiley & Sons, Ltd. KW - mechanotransduction KW - hydrogel KW - gelatin KW - cell encapsulation KW - matrix elasticity Y1 - 2017 U6 - https://doi.org/10.1002/pat.3947 SN - 1042-7147 SN - 1099-1581 VL - 28 SP - 1245 EP - 1251 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Brunacci, Nadia A1 - Wischke, Christian A1 - Naolou, Toufik A1 - Neffe, Axel T. A1 - Lendlein, Andreas T1 - Influence of surfactants on depsipeptide submicron particle formation JF - European Journal of Pharmaceutics and Biopharmaceutics N2 - Surfactants are required for the formation and stabilization of hydrophobic polymeric particles in aqueous environment. In order to form submicron particles of varying sizes from oligo[3-(S)-sec-butylmorpholine-2,5-dione]diols ((OBMD)-diol), different surfactants were investigated. As new surfactants, four-armed star-shaped oligo(ethylene glycol)s of molecular weights of 5-20 kDa functionalized with desamino-tyrosine (sOEG-DAT) resulted in smaller particles with lower PDI than with desaminotyrosyl tyrosine (sOEG-DATT) in an emulsion/solvent evaporation method. In a second set of experiments, sOEG-DAT of M-n= 10 kDa was compared with the commonly employed emulsifiers polyvinylalcohol (PVA), polyoxyethylene (20) sorbitan monolaurate (Tween 20), and D-alpha-tocopherol polyethylene glycol succinate (VIT E-TPGS) for OBMD particle preparation. sOEG-DAT allowed to systematically change sizes in a range of 300 up to 900 nm with narrow polydispersity, while in the other cases, a lower size range (250-400 nm, PVA; 300 nm, Tween 20) or no effective particle formation was observed. The ability of tailoring particle size in a broad range makes sOEG-DAT of particular interest for the formation of oligodepsipeptide particles, which can further be investigated as drug carriers for controlled delivery. (C) 2016 Elsevier B.V. All rights reserved. KW - Depsipeptide KW - Particle size KW - Surfactants KW - Submicron particles Y1 - 2017 U6 - https://doi.org/10.1016/j.ejpb.2016.11.011 SN - 0939-6411 SN - 1873-3441 VL - 116 SP - 61 EP - 65 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Dal Bianco, Andrea A1 - Wischke, Christian A1 - Zhou, Shuo A1 - Lendlein, Andreas T1 - Controlling surface properties and permeability of polyglycerol network films JF - Polymers for advanced technologies N2 - While branched polyglycerol (PG)-based molecules are well established as hydrophilic particles, the capacity of utilizing PG in bulk materials and opportunities arising by their further surface functionalization have only recently been considered. Here we investigated how the mold used in PG network synthesis may affect surface composition and how the permeability of substances through PG can be controlled by altering network structure, i.e. introducing 20mol% oligoethylene glycol (OEG) bifunctional spacer molecules. Overall, PG-based bulk network materials were shown to be tailorable, hydrophilic, low swelling and relatively stiff polyether-based materials, with low impact of salt onto material properties. Based on these features, but also on the principal capacity of free hydroxyl groups to be used for functionalization reactions, these materials may be an interesting platform for medical and technical applications, e.g. as diffusion-rate controlling membrane in aqueous environment. Copyright (c) 2016 John Wiley & Sons, Ltd. KW - polyglycerol KW - surface properties KW - diffusion KW - network structure Y1 - 2017 U6 - https://doi.org/10.1002/pat.3917 SN - 1042-7147 SN - 1099-1581 VL - 28 SP - 1263 EP - 1268 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Farhan, Muhammad A1 - Rudolph, Tobias A1 - Nöchel, Ulrich A1 - Yan, Wan A1 - Kratz, Karl A1 - Lendlein, Andreas T1 - Noncontinuously Responding Polymeric Actuators JF - ACS applied materials & interfaces N2 - Reversible movements of current polymeric actuators stem from the continuous response to signals from a controlling unit, and subsequently cannot be interrupted without stopping or eliminating the input trigger. Here, we present actuators based on cross-linked blends of two crystallizable polymers capable of pausing their movements in a defined manner upon continuous cyclic heating and cooling. This noncontinuous actuation can be adjusted by varying the applied heating and cooling rates. The feasibility of these devices for technological applications was shown in a 140 cycle experiment of free-standing noncontinuous shape shifts, as well as by various demonstrators. KW - soft robotics KW - polymer actuators KW - thermo-sensitivity KW - shape shifting materials KW - crystallization behavior Y1 - 2017 U6 - https://doi.org/10.1021/acsami.7b11316 SN - 1944-8244 VL - 9 SP - 33559 EP - 33564 PB - American Chemical Society CY - Washington ER - TY - JOUR A1 - Haase, Tobias A1 - Krost, Annalena A1 - Sauter, Tilman A1 - Kratz, Karl A1 - Peter, Jan A1 - Kamann, Stefanie A1 - Jung, Friedrich A1 - Lendlein, Andreas A1 - Zohlnhöfer, Dietlind A1 - Rüder, Constantin T1 - In vivo biocompatibility assessment of poly (ether imide) electrospun scaffolds JF - Journal of Tissue Engineering and Regenerative Medicine N2 - Poly(ether imide) (PEI), which can be chemically functionalized with biologically active ligands, has emerged as a potential biomaterial for medical implants. Electrospun PEI scaffolds have shown advantageous properties, such as enhanced endothelial cell adherence, proliferation and low platelet adhesion in in vitro experiments. In this study, the in vivo behaviour of electrospun PEI scaffolds and PEI films was examined in a murine subcutaneous implantation model. Electrospun PEI scaffolds and films were surgically implanted subcutaneously in the dorsae of mice. The surrounding subcutaneous tissue response was examined via histopathological examination at 7 and 28days after implantation. No serious adverse events were observed for both types of PEI implants. The presence of macrophages or foreign body giant cells in the vicinity of the implants and the formation of a fibrous capsule indicated a normal foreign body reaction towards PEI films and scaffolds. Capsule thickness and inflammatory infiltration cells significantly decreased for PEI scaffolds during days 7-28 while remaining unchanged for PEI films. The infiltration of cells into the implant was observed for PEI scaffolds 7days after implantation and remained stable until 28days of implantation. Additionally some, but not all, PEI scaffold implants induced the formation of functional blood vessels in the vicinity of the implants. Conclusively, this study demonstrates the in vivo biocompatibility of PEI implants, with favourable properties of electrospun PEI scaffolds regarding tissue integration and wound healing. KW - poly(ether imide) KW - in vivo study KW - electrospun scaffold KW - capsule formation KW - foreign body giant cells KW - vascularization Y1 - 2017 U6 - https://doi.org/10.1002/term.2002 SN - 1932-6254 SN - 1932-7005 VL - 11 IS - 4 SP - 1034 EP - 1044 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Heuchel, Matthias A1 - Gerber, David A1 - Kratz, Karl A1 - Lendlein, Andreas T1 - Morphological analysis of differently sized highly porous poly(ether imide) microparticles by mercury porosimetry JF - Polymers for advanced technologies N2 - Highly porous poly(ether imide) (PEI) microparticles prepared by a spraying/coagulation process are discussed as candidate adsorber materials for apheresis applications, i.e. removal of uremic toxins from the blood of renal failure patients. PEI particles obtained by the aforementioned procedure can have a broad size distribution with particle diameters ranging from 20 to 800 mu m. In order to further estimate the adsorption behavior of PEI microparticles packed in application relevant apheresis modules, a quantitative information about the relation between particle size and pore morphology is required. In this study, we explored whether the intraparticle porosity of PEI microparticles varies with altering the diameter of the particulate adsorbers. By an analytical wet sieving procedure, the obtained PEI microparticles were separated into five size fractions, which were analyzed by mercury intrusion porosimetry, nitrogen adsorption, and scanning electron microscopy. Mercury intrusion porosimetry revealed for all size fractions high porosity values in the range from 78% to 84% with pore diameters in the range from 10 to 1000nm. A bimodal pore size distribution was found having a first peak at around 100nm, while a second pronounced peak maximum was found at higher pore sizes that increased with raising particle diameter from 300nm for the smallest particle size fraction (50-100 mu m) to 700nm for particles with a diameter of 200 to 250 mu m. Based on these findings, it can be assumed that the main PEI particle size fraction (200-250 mu m) should exhibit the highest adsorption capacity in an apheresis module. Copyright (c) 2016 John Wiley & Sons, Ltd. KW - porous microparticles KW - poly(ether imide) KW - mercury intrusion porosimetry KW - adsorber materials Y1 - 2017 U6 - https://doi.org/10.1002/pat.3973 SN - 1042-7147 SN - 1099-1581 VL - 28 SP - 1269 EP - 1277 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Hommes-Schattmann, Paul J. A1 - Neffe, Axel T. A1 - Ahmad, Bilal A1 - Williams, Gareth R. A1 - Vanneaux, Valerie A1 - Menasche, Philippe A1 - Kalfa, David A1 - Lendlein, Andreas T1 - RGD constructs with physical anchor groups as polymer co-electrospinnable cell adhesives JF - Polymers for advanced technologies N2 - The tissue integration of synthetic polymers can be promoted by displaying RGD peptides at the biointerface with the objective of enhancing colonization of the material by endogenous cells. A firm but flexible attachment of the peptide to the polymer matrix, still allowing interaction with receptors, is therefore of interest. Here, the covalent coupling of flexible physical anchor groups, allowing for temporary immobilization on polymeric surfaces via hydrophobic or dipole-dipole interactions, to a RGD peptide was investigated. For this purpose, a stearate or an oligo(ethylene glycol) (OEG) was attached to GRGDS in 51-69% yield. The obtained RGD linker constructs were characterized by NMR, IR and MALDI-ToF mass spectrometry, revealing that the commercially available OEG and stearate linkers are in fact mixtures of similar compounds. The RGD linker constructs were co-electrospun with poly(p-dioxanone) (PPDO). After electrospinning, nitrogen could be detected on the surface of the PPDO fibers by X-ray photoelectron spectroscopy. The nitrogen content exceeded the calculated value for the homogeneous material mixture suggesting a pronounced presentation of the peptide on the fiber surface. Increasing amounts of RGD linker constructs in the electrospinning solution did not lead to a detection of an increased amount of peptide on the scaffold surface, suggesting inhomogeneous distribution of the peptide on the PPDO fiber surface. Human adipose-derived stem cells cultured on the patches showed similar viability as when cultured on PPDO containing pristine RGD. The fully characterized RGD linker constructs could serve as valuable tools for the further development of tissue-integrating polymeric scaffolds. Copyright (c) 2016 John Wiley & Sons, Ltd. KW - electrospinning KW - RGD peptides KW - cell adhesion KW - biofunctionalization Y1 - 2017 U6 - https://doi.org/10.1002/pat.3963 SN - 1042-7147 SN - 1099-1581 VL - 28 SP - 1312 EP - 1317 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Li, Zhengdong A1 - Xu, Xun A1 - Wang, Weiwei A1 - Kratz, Karl A1 - Sun, Xianlei A1 - Zou, Jie A1 - Deng, Zijun A1 - Jung, Friedrich Wilhelm A1 - Gossen, Manfred A1 - Ma, Nan A1 - Lendlein, Andreas T1 - Modulation of the mesenchymal stem cell migration capacity via preconditioning with topographic microstructure JF - Clinical hemorheology and microcirculation : blood flow and vessels N2 - Controlling mesenchymal stem cells (MSCs) behavior is necessary to fully exploit their therapeutic potential. Various approaches are employed to effectively influence the migration capacity of MSCs. Here, topographic microstructures with different microscale roughness were created on polystyrene (PS) culture vessel surfaces as a feasible physical preconditioning strategy to modulate MSC migration. By analyzing trajectories of cells migrating after reseeding, we demonstrated that the mobilization velocity of human adipose derived mesenchymal stem cells (hADSCs) could be promoted by and persisted after brief preconditioning with the appropriate microtopography. Moreover, the elevated activation levels of focal adhesion kinase (FAK) and mitogen-activated protein kinase (MAPK) in hADSCs were also observed during and after the preconditioning process. These findings underline the potential enhancement of in vivo therapeutic efficacy in regenerative medicine via transplantation of topographic microstructure preconditioned stem cells. KW - Mesenchymal stem cells KW - precondition KW - microstructure KW - migration KW - FAK-MAPK Y1 - 2017 U6 - https://doi.org/10.3233/CH-179208 SN - 1386-0291 SN - 1875-8622 VL - 67 SP - 267 EP - 278 PB - IOS Press CY - Amsterdam ER - TY - JOUR A1 - Liu, Yue A1 - Razzaq, Muhammad Yasar A1 - Rudolph, Tobias A1 - Fang, Liang A1 - Kratz, Karl A1 - Lendlein, Andreas T1 - Two-Level Shape Changes of Polymeric Microcuboids Prepared from Crystallizable Copolymer Networks JF - Macromolecules : a publication of the American Chemical Society N2 - Polymeric microdevices bearing features like nonspherical shapes or spatially segregated surface properties are of increasing importance in biological and medical analysis, drug delivery, and bioimaging or microfluidic systems as well as in micromechanics, sensors, information storage, or data carrier devices. Here, a method to fabricate programmable microcuboids with shape-memory capability and the quantification of their recovery at different levels is reported. The method uses the soft lithographic technique to create microcuboids with well-defined sizes and surface properties. Microcuboids having an edge length of 25 mu m and a height of 10 mu m were prepared from cross-linked poly[ethylene-co-(vinyl acetate)] (cPEVA) with different vinyl acetate contents and were programmed by compression with various deformation degrees at elevated temperatures. The microlevel shape-recovery of the cuboidal geometry during heating was monitored by optical microscopy (OM) and atomic force microscopy (AFM) studying the related changes in the projected area (PA) or height, while the nanolevel changes of the nanosurface roughness were investigated by in situ AFM. The shape-memory effect at the microlevel was quantified by the recovery ratio of cuboids (R-r,R-micro), while at the. nanolevel, the recovery ratio of the nanoroughness (R-r,R-nano) was measured. The values of R-r,R-micro,,micro could be tailored in a range from 42 +/- 1% to 102 +/- 1% and Rr,nano from 89 +/- 6% to 136 +/- 21% depending on the applied compression ratio and the amount of vinyl acetate content in the cPEVA microcuboids. Y1 - 2017 U6 - https://doi.org/10.1021/acs.macromol.6b02237 SN - 0024-9297 SN - 1520-5835 VL - 50 SP - 2518 EP - 2527 PB - American Chemical Society CY - Washington ER -