TY - JOUR A1 - Weiler, Markus A1 - Menzel, Christoph A1 - Pertsch, Thomas A1 - Alaee, Rasoul A1 - Rockstuhl, Carsten A1 - Pacholski, Claudia T1 - Bottom-Up Fabrication of Hybrid Plasmonic Sensors: Gold-Capped Hydrogel Microspheres Embedded in Periodic Metal Hole Arrays JF - Polymer : the international journal for the science and technology of polymers N2 - The high potential of bottom-up fabrication strategies for realizing sophisticated optical sensors combining the high sensitivity of a surface plasmon resonance with the exceptional properties of stimuli-responsive hydrogel is demonstrated. The sensor is composed of a periodic hole array in a gold film whose holes are filled with gold-capped poly(N-isoproyl-acrylamide) (polyNIPAM) microspheres. The production of this sensor relies on a pure chemical approach enabling simple, time-efficient, and cost-efficient preparation of sensor platforms covering areas of cm(2). The transmission spectrum of this plasmonic sensor shows a strong interaction between propagating surface plasmon polaritons at the metal film surface and localized surface plasmon resonance of the gold cap on top of the polyNIPAM microspheres. Computer simulations support this experimental observation. These interactions lead to distinct changes in the transmission spectrum, which allow for the simultaneous, sensitive optical detection of refractive index changes in the surrounding medium and the swelling state of the embedded polyNIPAM microsphere under the gold cap. The volume of the polyNIPAM microsphere located underneath the gold cap can be changed by certain stimuli such as temperature, pH, ionic strength, and distinct molecules bound to the hydrogel matrix facilitating the detection of analytes which do not change the refractive index of the surrounding medium significantly. KW - bottom-up KW - hydrogel KW - hole array KW - sensor KW - surface plasmon resonance Y1 - 2016 U6 - https://doi.org/10.1021/acsami.6b08636 SN - 1944-8244 VL - 8 SP - 26392 EP - 26399 PB - American Chemical Society CY - Washington ER - TY - GEN A1 - Riedelsberger, Janin A1 - Dreyer, Ingo A1 - Gonzalez, Wendy T1 - Outward rectification of voltage-gated K+ channels evolved at least twice in life history T2 - Postprints der Universität Potsdam : Mathematisch-Naturwissenschaftliche Reihe N2 - Voltage-gated potassium (K+) channels are present in all living systems. Despite high structural similarities in the transmembrane domains (TMD), this K+ channel type segregates into at least two main functional categories-hyperpolarization-activated, inward-rectifying (Kin) and depolarization-activated, outward-rectifying (Kout) channels. Voltage-gated K+ channels sense the membrane voltage via a voltage-sensing domain that is connected to the conduction pathway of the channel. It has been shown that the voltage-sensing mechanism is the same in Kin and Kout channels, but its performance results in opposite pore conformations. It is not known how the different coupling of voltage-sensor and pore is implemented. Here, we studied sequence and structural data of voltage-gated K+ channels from animals and plants with emphasis on the property of opposite rectification. We identified structural hotspots that alone allow already the distinction between Kin and Kout channels. Among them is a loop between TMD S5 and the pore that is very short in animal Kout, longer in plant and animal Kin and the longest in plant Kout channels. In combination with further structural and phylogenetic analyses this finding suggests that outward-rectification evolved twice and independently in the animal and plant kingdom. T3 - Zweitveröffentlichungen der Universität Potsdam : Mathematisch-Naturwissenschaftliche Reihe - 521 KW - multiple sequence alignment KW - potassium channel KW - Arabidopsis thaliana KW - inward rectification KW - pacemaker channels KW - S4-S5 linker KW - sensor KW - expression KW - mechanism KW - activation Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-409594 SN - 1866-8372 IS - 521 ER - TY - THES A1 - Heinsohn, Natascha T1 - Development of a fiber-based sensor for the molecular detection of pathogens using Legionella as an example T1 - Entwicklung eines Faser-basierten Sensors zur molekularen Detektion von Pathogenen am Beispiel von Legionellen N2 - Fiber-based microfluidics has undergone many innovative developments in recent years, with exciting examples of portable, cost-effective and easy-to-use detection systems already being used in diagnostic and analytical applications. In water samples, Legionella are a serious risk as human pathogens. Infection occurs through inhalation of aerosols containing Legionella cells and can cause severe pneumonia and may even be fatal. In case of Legionella contamination of water-bearing systems or Legionella infection, it is essential to find the source of the contamination as quickly as possible to prevent further infections. In drinking, industrial and wastewater monitoring, the culture-based method is still the most commonly used technique to detect Legionella contamination. In order to improve the laboratory-dependent determination, the long analysis times of 10-14 days as well as the inaccuracy of the measured values in colony forming units (CFU), new innovative ideas are needed. In all areas of application, for example in public, commercial or private facilities, rapid and precise analysis is required, ideally on site. In this PhD thesis, all necessary single steps for a rapid DNA-based detection of Legionella were developed and characterized on a fiber-based miniaturized platform. In the first step, a fast, simple and device-independent chemical lysis of the bacteria and extraction of genomic DNA was established. Subsequently, different materials were investigated with respect to their non-specific DNA retention. Glass fiber filters proved to be particularly suitable, as they allow recovery of the DNA sample from the fiber material in combination with dedicated buffers and exhibit low autofluorescence, which was important for fluorescence-based readout. A fiber-based electrophoresis unit was developed to migrate different oligonucleotides within a fiber matrix by application of an electric field. A particular advantage over lateral flow assays is the targeted movement, even after the fiber is saturated with liquid. For this purpose, the entire process of fiber selection, fiber chip patterning, combination with printed electrodes, and testing of retention and migration of different DNA samples (single-stranded, double-stranded and genomic DNA) was performed. DNA could be pulled across the fiber chip in an electric field of 24 V/cm within 5 minutes, remained intact and could be used for subsequent detection assays e.g., polymerase chain reaction (PCR) or fluorescence in situ hybridization (FISH). Fiber electrophoresis could also be used to separate DNA from other components e.g., proteins or cell lysates or to pull DNA through multiple layers of the glass microfiber. In this way, different fragments experienced a moderate, size-dependent separation. Furthermore, this arrangement offers the possibility that different detection reactions could take place in different layers at a later time. Electric current and potential measurements were collected to investigate the local distribution of the sample during migration. While an increase in current signal at high concentrations indicated the presence of DNA samples, initial experiments with methylene blue stained DNA showed a temporal sequence of signals, indicating sample migration along the chip. For the specific detection of a Legionella DNA, a FISH-based detection with a molecular beacon probe was tested on the glass microfiber. A specific region within the 16S rRNA gene of Legionella spp. served as a target. For this detection, suitable reaction conditions and a readout unit had to be set up first. Subsequently, the sensitivity of the probe was tested with the reverse complementary target sequence and the specificity with several DNA fragments that differed from the target sequence. Compared to other DNA sequences of similar length also found in Legionella pneumophila, only the target DNA was specifically detected on the glass microfiber. If a single base exchange is present or if two bases are changed, the probe can no longer distinguish between the DNA targets and non-targets. An analysis with this specificity can be achieved with other methods such as melting point determination, as was also briefly indicated here. The molecular beacon probe could be dried on the glass microfiber and stored at room temperature for more than three months, after which it was still capable of detecting the target sequence. Finally, the feasibility of fiber-based FISH detection for genomic Legionella DNA was tested. Without further processing, the probe was unable to detect its target sequence in the complex genomic DNA. However, after selecting and application of appropriate restriction enzymes, specific detection of Legionella DNA against other aquatic pathogens with similar fragment patterns as Acinetobacter haemolyticus was possible. N2 - Die faserbasierte Mikrofluidik hat in den letzten Jahren viele innovative Entwicklungen erfahren, mit spannenden Beispielen für portable, kostengünstige und einfach zu bedienende Nachweissysteme die bereits in diagnostischen und analytischen Fragestellungen Anwendung finden. In Wasserproben sind Legionellen als Humanpathogene ein ernstzunehmendes Risiko. Eine Infektion erfolgt über das Einatmen legionellenhaltiger Aerosole und kann schwerwiegende Pneumonien hervorrufen oder sogar tödlich verlaufen. Im Falle einer Legionellenkontamination von Wasserführenden Systemen beziehungsweise einer Legionellen-assoziierten Infektion ist es maßbeglich die Quelle der Kontamination möglichst schnell zu finden, um weitere Infektionen zu vermeiden. In der Überwachung von Trink- Prozess- und Abwasser ist die kulturbasierte Methode immer noch die am häufigsten verwendete Technik, um einen Legionellenbefall nachzuweisen. Um Alternativen zu einer laborabhängigen Bestimmung mit ihren langen Analysezeiten von 10-14 Tagen und der ungenauen Messwertausgabe in koloniebildenden Einheiten (KBE) zu finden, bedarf es neuer innovativer Ideen. In allen Anwendungsbereichen, zum Beispiel in öffentlichen, gewerblichen oder privaten Einrichtungen, ist eine schnelle und präzise Analyse erforderlich, idealerweise vor Ort. Im Rahmen dieser Doktorarbeit wurden alle notwendigen Einzelschritte für einen schnellen DNA-basierten Nachweis von Legionellen auf einer faserbasierten, miniaturisierten Plattform entwickelt und charakterisiert. Im ersten Schritt wurde eine schnelle, einfache und geräteunabhängige chemische Lyse der Bakterien und Extraktion der genomischen DNA etabliert. Daraufhin wurden verschiedene Materialien hinsichtlich Ihres unspezifischen DNA-Rückhalts untersucht. Glasfaserfilter erwiesen sich als besonders geeignet, da sie in Kombination mit den geeigneten Puffern eine Rückgewinnung der DNA-Probe aus dem Fasermaterial ermöglichen und für eine fluoreszenzbasierte Auslese eine geringe Autofluoreszenz aufweisen. Eine faserbasierte Elektrophoreseeinheit wurde entwickelt, um durch Anlegen eines elektrischen Feldes verschiedene Oligonukleotide innerhalb einer Fasermatrix zu bewegen. Ein besonderer Vorteil gegenüber Lateral-Flow-Tests ist die Möglichkeit der gezielten Bewegung, auch nachdem die Faser mit Flüssigkeit gesättigt ist. Hierfür wurde der gesamte Prozess der Faserauswahl, der Strukturierung der Faserchips, der Kombination mit gedruckten Elektroden und der Prüfung der Retention und Migration verschiedener DNA-Proben (einzelsträngige, doppelsträngige und genomische DNA) bearbeitet. Die DNA konnte in einem elektrischen Feld von 24 V/cm innerhalb von 5 Minuten über den Faserchip gezogen werden, blieb dabei intakt und konnte für nachfolgende Detektionsnachweise z.B. Polymerase-Ketten-Reaktion (PCR) oder Fluoreszenz in situ Hybridisierung (FISH) genutzt werden. Die Faserelektrophorese konnte außerdem zur Separation der DNA von anderen Komponenten z.B. Proteinen oder Zelllysaten verwendet werden oder um DNA durch mehrere Lagen der Glasfaser zu steuern. Dabei erfuhren verschiedene Fragmente einen moderaten, größenabhängigen Trenneffekt. Außerdem bietet diese Anordnung die Möglichkeit, dass unterschiedliche Nachweisreaktionen zu einem späteren Zeitpunkt in verschiedenen Schichten stattfinden könnten. Strom- und Potentialmessungen wurden erhoben, um die lokale Verteilung der Probe während der Migration zu untersuchen. Während ein Anstieg des Stromsignals bei hohen Konzentrationen die Anwesenheit von DNA-Proben anzeigte, konnten nach ersten Experimenten mit Methylenblau-gefärbter DNA zeitlich aufeinanderfolgende Signale detektiert werden und somit prinzipiell eine Probenmigration nachgewiesen werden. Für den spezifischen Nachweis der Legionellen-DNA wurde ein FISH-basierter Nachweis mit einer molekularen Sonde auf der Glasmikrofaser getestet. Als Ziel für die Sonde diente eine bestimmte Region innerhalb des 16S rRNA-Gens von Legionellen. Für diesen Nachweis mussten zunächst geeignete Reaktionsbedingungen und eine Ausleseeinheit bestimmt werden. Anschließend wurde die Sensitivität der Sonde mit der umgekehrt komplementären Zielsequenz und die Spezifität mit verschiedenen DNA-Fragmenten, die sich von der Zielsequenz unterschieden, getestet. Im Vergleich zu abweichenden DNA-Sequenzen ähnlicher Länge, die auch in Legionella pneumophila vorkommen, wurde nur die Ziel-DNA spezifisch auf der Glasmikrofaser erkannt. Liegt ein einzelner Basenaustausch vor oder werden zwei Basen geändert, so kann die Sonde nicht mehr zwischen der Ziel-DNA und den abweichenden DNA-Fragmenten unterscheiden. Eine Detektion mit dieser Genauigkeit ist mit anderen Methoden wie z.B. der Schmelzpunktbestimmung möglich, wie hier prinzipiell demonstriert wurde. Es wurde ferner gezeigt, dass die Sonde auf der Glasmikrofaser eingetrocknet und über drei Monate bei Raumtemperatur gelagert werden kann und danach immer noch in der Lage ist, die Zielsequenz nachzuweisen. Schließlich wurde die Anwendbarkeit des faserbasierten FISH-Nachweises auch für genomische Legionellen-DNA getestet. Ohne weitere Prozessierung war die Sonde nicht in der Lage ihre Zielsequenz in der komplexen genomischen DNA zu erkennen. Nach der Auswahl und Anwendung geeigneter Restriktionsenzyme war eine spezifische Detektion der Legionellen-DNA gegenüber anderen Wasserkeimen mit ähnlichem Fragmentmuster wie Acinetobacter haemolyticus möglich. KW - Sensor KW - paper-based KW - Legionellen KW - Legionella KW - papier-basiert KW - sensor KW - Detektionssystem KW - detection system KW - Glasfaser KW - glass fiber Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-566833 ER - TY - JOUR A1 - Chromik, Jonas A1 - Kirsten, Kristina A1 - Herdick, Arne A1 - Kappattanavar, Arpita Mallikarjuna A1 - Arnrich, Bert T1 - SensorHub BT - Multimodal sensing in real-life enables home-based studies JF - Sensors N2 - Observational studies are an important tool for determining whether the findings from controlled experiments can be transferred into scenarios that are closer to subjects' real-life circumstances. A rigorous approach to observational studies involves collecting data from different sensors to comprehensively capture the situation of the subject. However, this leads to technical difficulties especially if the sensors are from different manufacturers, as multiple data collection tools have to run simultaneously. We present SensorHub, a system that can collect data from various wearable devices from different manufacturers, such as inertial measurement units, portable electrocardiographs, portable electroencephalographs, portable photoplethysmographs, and sensors for electrodermal activity. Additionally, our tool offers the possibility to include ecological momentary assessments (EMAs) in studies. Hence, SensorHub enables multimodal sensor data collection under real-world conditions and allows direct user feedback to be collected through questionnaires, enabling studies at home. In a first study with 11 participants, we successfully used SensorHub to record multiple signals with different devices and collected additional information with the help of EMAs. In addition, we evaluated SensorHub's technical capabilities in several trials with up to 21 participants recording simultaneously using multiple sensors with sampling frequencies as high as 1000 Hz. We could show that although there is a theoretical limitation to the transmissible data rate, in practice this limitation is not an issue and data loss is rare. We conclude that with modern communication protocols and with the increasingly powerful smartphones and wearables, a system like our SensorHub establishes an interoperability framework to adequately combine consumer-grade sensing hardware which enables observational studies in real life. KW - multimodal sensing KW - home-based studies KW - activity recognition KW - sensor KW - systems KW - ecological momentary assessment KW - digital health Y1 - 2022 U6 - https://doi.org/10.3390/s22010408 SN - 1424-8220 VL - 22 IS - 1 PB - MDPI CY - Basel ER -