TY - JOUR A1 - Schaefer, Laura A1 - Bittmann, Frank T1 - Case report BT - Individualized pulsed electromagnetic field therapy in a Long COVID patient using the adaptive force as biomarker JF - Frontiers in medicine N2 - The increasing prevalence of Long COVID is an imminent public health disaster, and established approaches have not provided adequate diagnostics or treatments. Recently, anesthetic blockade of the stellate ganglion was reported to improve Long COVID symptoms in a small case series, purportedly by "rebooting" the autonomic nervous system. Here, we present a novel diagnostic approach based on the Adaptive Force (AF), and report sustained positive outcome for one severely affected Long COVID patient using individualized pulsed electromagnetic field (PEMF) at the area C7/T1. AF reflects the capacity of the neuromuscular system to adapt adequately to external forces in an isometric holding manner. In case, maximal isometric AF (AFiso(max)) is exceeded, the muscle merges into eccentric muscle action. Thereby, the force usually increases further until maximal AF (AFmax) is reached. In case adaptation is optimal, AFiso(max) is similar to 99-100% of AFmax. This holding capacity (AFiso(max)) was found to be vulnerable to disruption by unpleasant stimulus and, hence, was regarded as functional parameter. AF was assessed by an objectified manual muscle test using a handheld device. Prior to treatment, AFiso(max) was considerably lower than AFmax for hip flexors (62 N = similar to 28% AFmax) and elbow flexors (71 N = similar to 44% AFmax); i.e., maximal holding capacity was significantly reduced, indicating dysfunctional motor control. We tested PEMF at C7/T1, identified a frequency that improved neuromuscular function, and applied it for similar to 15 min. Immediately post-treatment, AFiso(max) increased to similar to 210 N (similar to 100% AFmax) at hip and 184 N (similar to 100% AFmax) at elbow. Subjective Long COVID symptoms resolved the following day. At 4 weeks post-treatment, maximal holding capacity was still on a similarly high level as for immediately post-treatment (similar to 100% AFmax) and patient was symptom-free. At 6 months the patient's Long COVID symptoms have not returned. This case report suggests (1) AF could be a promising diagnostic for post-infectious illness, (2) AF can be used to test effective treatments for post-infectious illness, and (3) individualized PEMF may resolve post-infectious symptoms. KW - individualized pulsed electromagnetic field KW - Adaptive Force KW - muscular holding capacity KW - case report KW - Long COVID KW - post-COVID syndrome KW - muscle weakness KW - fatigue Y1 - 2023 U6 - https://doi.org/10.3389/fmed.2022.879971 SN - 2296-858X VL - 9 PB - Frontiers Media CY - Lausanne ER - TY - JOUR A1 - Schaefer, Laura A1 - Carnarius, Friederike A1 - Dech, Silas A1 - Bittmann, Frank T1 - Repeated measurements of Adaptive Force BT - maximal holding capacity differs from other maximal strength parameters and preliminary characteristics for non-professional strength vs. endurance athletes JF - Frontiers in physiology N2 - The Adaptive Force (AF) reflects the neuromuscular capacity to adapt to external loads during holding muscle actions and is similar to motions in real life and sports. The maximal isometric AF (AFisoₘₐₓ) was considered to be the most relevant parameter and was assumed to have major importance regarding injury mechanisms and the development of musculoskeletal pain. The aim of this study was to investigate the behavior of different torque parameters over the course of 30 repeated maximal AF trials. In addition, maximal holding vs. maximal pushing isometric muscle actions were compared. A side consideration was the behavior of torques in the course of repeated AF actions when comparing strength and endurance athletes. The elbow flexors of n = 12 males (six strength/six endurance athletes, non-professionals) were measured 30 times (120 s rest) using a pneumatic device. Maximal voluntary isometric contraction (MVIC) was measured pre and post. MVIC, AFisoₘₐₓ, and AFₘₐₓ (maximal torque of one AF measurement) were evaluated regarding different considerations and statistical tests. AFₘₐₓ and AFisoₘₐₓ declined in the course of 30 trials [slope regression (mean ± standard deviation): AFₘₐₓ = −0.323 ± 0.263; AFisoₘₐₓ = −0.45 ± 0.45]. The decline from start to end amounted to −12.8% ± 8.3% (p < 0.001) for AFₘₐₓ and −25.41% ± 26.40% (p < 0.001) for AFisoₘₐₓ. AF parameters declined more in strength vs. endurance athletes. Thereby, strength athletes showed a rather stable decline for AFmax and a plateau formation for AFisoₘₐₓ after 15 trials. In contrast, endurance athletes reduced their AFₘₐₓ, especially after the first five trials, and remained on a rather similar level for AFisomax. The maximum of AFisoₘₐₓ of all 30 trials amounted 67.67% ± 13.60% of MVIC (p < 0.001, n = 12), supporting the hypothesis of two types of isometric muscle action (holding vs. pushing). The findings provided the first data on the behavior of torque parameters after repeated isometric–eccentric actions and revealed further insights into neuromuscular control strategies. Additionally, they highlight the importance of investigating AF parameters in athletes based on the different behaviors compared to MVIC. This is assumed to be especially relevant regarding injury mechanisms. KW - Adaptive Force KW - maximal isometric Adaptive Force KW - holding capacity KW - neuromuscular control KW - strength vs. endurance athletes KW - injury mechanisms KW - repeated adaptive isometric–eccentric muscle action KW - holding (HIMA) and pushing (PIMA) isometric muscle action Y1 - 2023 U6 - https://doi.org/10.3389/fphys.2023.1020954 SN - 1664-042X VL - 14 PB - Frontiers Research Foundation CY - Lausanne ER - TY - JOUR A1 - Schaefer, Laura A1 - Bittmann, Frank T1 - The adaptive force as a potential biomechanical parameter in the recovery process of patients with long COVID JF - Diagnostics N2 - Long COVID patients show symptoms, such as fatigue, muscle weakness and pain. Adequate diagnostics are still lacking. Investigating muscle function might be a beneficial approach. The holding capacity (maximal isometric Adaptive Force; AFisomax) was previously suggested to be especially sensitive for impairments. This longitudinal, non-clinical study aimed to investigate the AF in long COVID patients and their recovery process. AF parameters of elbow and hip flexors were assessed in 17 patients at three time points (pre: long COVID state, post: immediately after first treatment, end: recovery) by an objectified manual muscle test. The tester applied an increasing force on the limb of the patient, who had to resist isometrically for as long as possible. The intensity of 13 common symptoms were queried. At pre, patients started to lengthen their muscles at ~50% of the maximal AF (AFmax), which was then reached during eccentric motion, indicating unstable adaptation. At post and end, AFisomax increased significantly to ~99% and 100% of AFmax, respectively, reflecting stable adaptation. AFmax was statistically similar for all three time points. Symptom intensity decreased significantly from pre to end. The findings revealed a substantially impaired maximal holding capacity in long COVID patients, which returned to normal function with substantial health improvement. AFisomax might be a suitable sensitive functional parameter to assess long COVID patients and to support therapy process KW - Adaptive Force KW - maximal isometric Adaptive Force KW - holding capacity KW - muscle function KW - long COVID fatigue KW - post COVID syndrome KW - muscle weakness KW - neuromuscular control KW - biomechanical parameter Y1 - 2023 U6 - https://doi.org/10.3390/diagnostics13050882 SN - 2075-4418 VL - 13 IS - 5 PB - MDPI CY - Basel ER - TY - JOUR A1 - Schaefer, Laura A1 - Dech, Silas A1 - Wolff, Lara L. A1 - Bittmann, Frank T1 - Emotional Imagery Influences the Adaptive Force in Young Women BT - Unpleasant Imagery Reduces Instantaneously the Muscular Holding Capacity JF - Brain Sciences N2 - The link between emotions and motor function has been known for decades but is still not clarified. The Adaptive Force (AF) describes the neuromuscular capability to adapt to increasing forces and was suggested to be especially vulnerable to interfering inputs. This study investigated the influence of pleasant an unpleasant food imagery on the manually assessed AF of elbow and hip flexors objectified by a handheld device in 12 healthy women. The maximal isometric AF was significantly reduced during unpleasant vs. pleasant imagery and baseline (p < 0.001, dz = 0.98–1.61). During unpleasant imagery, muscle lengthening started at 59.00 ± 22.50% of maximal AF, in contrast to baseline and pleasant imagery, during which the isometric position could be maintained mostly during the entire force increase up to ~97.90 ± 5.00% of maximal AF. Healthy participants showed an immediately impaired holding function triggered by unpleasant imagery, presumably related to negative emotions. Hence, AF seems to be suitable to test instantaneously the effect of emotions on motor function. Since musculoskeletal complaints can result from muscular instability, the findings provide insights into the understanding of the causal chain of linked musculoskeletal pain and mental stress. A case example (current stress vs. positive imagery) suggests that the approach presented in this study might have future implications for psychomotor diagnostics and therapeutics. KW - Adaptive Force KW - maximal isometric Adaptive Force KW - holding capability KW - neuromuscular adaptation KW - motor control KW - pleasant and unpleasant imagery KW - emotions KW - emotional imagery KW - manual muscle test Y1 - 2022 U6 - https://doi.org/10.3390/brainsci12101318 SN - 2076-3425 VL - 12 IS - 10 PB - MDPI CY - Basel, Schweiz ER - TY - JOUR A1 - Schaefer, Laura A1 - Dech, Silas A1 - Bittmann, Frank T1 - Adaptive force and emotionally related imaginations BT - Preliminary results suggest a reduction of the maximal holding capacity as reaction to disgusting food imagination JF - Heliyon N2 - The link between emotions and motor control has been discussed for years. The measurement of the Adaptive Force (AF) provides the possibility to get insights into the adaptive control of the neuromuscular system in reaction to external forces. It was hypothesized that the holding isometric AF is especially vulnerable to disturbing inputs. Here, the behavior of the AF under the influence of positive (tasty) vs. negative (disgusting) food imaginations was investigated. The AF was examined in n = 12 cases using an objectified manual muscle test of the hip flexors, elbow flexors or pectoralis major muscle, performed by one of two experienced testers while the participants imagined their most tasty or most disgusting food. The reaction force and the limb position were measured by a handheld device. While the slope of force rises and the maximal AF did not differ significantly between tasty and disgusting imaginations (p > 0.05), the maximal isometric AF was significantly lower and the AF at the onset of oscillations was significantly higher under disgusting vs. tasty imaginations (both p = 0.001). A proper length tension control of muscles seems to be a crucial functional parameter of the neuromuscular system which can be impaired instantaneously by emotionally related negative imaginations. This might be a potential approach to evaluate somatic reactions to emotions. KW - Adaptive Force KW - Isometric Adaptive Force KW - Holding capacity KW - Holding KW - isometric muscle action KW - Imaginations KW - Emotions KW - Motor control KW - Functional weakness KW - Manual muscle test Y1 - 2021 U6 - https://doi.org/10.1016/j.heliyon.2021.e07827 SN - 2405-8440 VL - 7 IS - 8 PB - Elsevier CY - London ER - TY - JOUR A1 - Schaefer, Laura A1 - Bittmann, Frank T1 - Muscular Pre-Activation Can Boost the Maximal Explosive Eccentric Adaptive Force JF - Frontiers in Physiology N2 - The improvement of power is an objective in training of athletes. In order to detect effective methods of exercise, basic research is required regarding the mechanisms of muscular activity. The purpose of this study is to investigate whether or not a muscular pre-activation prior to an external impulse-like force impact has an effect on the maximal explosive eccentric Adaptive Force (xpAFeccmax). This power capability combines different probable power enhancing mechanisms. To measure the xpAFeccmax an innovative pneumatic device was used. During measuring, the subject tries to hold an isometric position as long as possible. In the moment in which the subjects’ maximal isometric holding strength is exceeded, it merges into eccentric muscle action. This process is very close to motions in sports, where an adaptation of the neuromuscular system is required, e.g., force impacts caused by uneven surfaces during skiing. For investigating the effect of pre-activation on the xpAFeccmax of the quadriceps femoris muscle, n = 20 subjects had to pass three different pre-activation levels in a randomized order (level 1: 0.4 bar, level 2: 0.8 bar, level 3: 1.2 bar). After adjusting the standardized pre-pressure by pushing against the interface, an impulse-like load impacted on the distal tibia of the subject. During this, the xpAFeccmax was detected. The maximal voluntary isometric contraction (MVIC) was also measured. The torque values of the xpAFeccmax were compared with regard to the pre-activation levels. The results show a significant positive relation between the pre-activation of the quadriceps femoris muscle and the xpAFeccmax (male: p = 0.000, η2= 0.683; female: p = 0.000, η2= 0.907). The average percentage increase of torque amounted +28.15 ± 25.4% between MVIC and xpAFeccmax with pre-pressure level 1, +12.09 ± 7.9% for the xpAFeccmax comparing pre-pressure levels 1 vs. 2 and +2.98 ± 4.2% comparing levels 2 and 3. A higher but not maximal muscular activation prior to a fast impacting eccentric load seems to produce an immediate increase of force outcome. Different possible physiological explanatory approaches and the use as a potential training method are discussed. KW - Adaptive Force KW - neuromuscular pre-activation KW - power improvement KW - muscular activity KW - adaptation to external force impact Y1 - 2019 U6 - https://doi.org/10.3389/fphys.2019.00910 SN - 1664-042X VL - 10 PB - Frontiers Research Foundation CY - Lausanne ER - TY - JOUR A1 - Schaefer, Laura A1 - Hoff, Marco A1 - Bittmann, Frank T1 - Measuring system and method of determining the Adaptive Force JF - European journal of translational myology N2 - The term Adaptive Force (AF) describes the capability of adaptation of the nerve-muscle-system to externally applied forces during isometric and eccentric muscle action. This ability plays an important role in real life motions as well as in sports. The focus of this paper is on the specific measurement method of this neuromuscular action, which can be seen as innovative. A measuring system based on the use of compressed air was constructed and evaluated for this neuromuscular function. It depends on the physical conditions of the subject, at which force level it deviates from the quasi isometric position and merges into eccentric muscle action. The device enables – in contrast to the isokinetic systems – a measure of strength without forced motion. Evaluation of the scientific quality criteria of the devices was done by measurements regarding the intra- and interrater-, the test-retest-reliability and fatiguing measurements. Comparisons of the pneumatic device with a dynamometer were also done. Looking at the mechanical evaluation, the results show a high level of consistency (r²=0.94 to 0.96). The parallel test reliability delivers a very high and significant correlation (ρ=0.976; p=0.000). Including the biological system, the concordance of three different raters is very high (p=0.001, Cronbachs alpha α=0.987). The test retest with 4 subjects over five weeks speaks for the reliability of the device in showing no statistically significant differences. These evaluations indicate that the scientific evaluation criteria are fulfilled. The specific feature of this system is that an isometric position can be maintained while the externally impacting force rises. Moreover, the device can capture concentric, static and eccentric strength values. Fields of application are performance diagnostics in sports and medicine. KW - Adaptive Force KW - isometric eccentric force KW - muscle action KW - motor control KW - strength measurement system Y1 - 2017 U6 - https://doi.org/10.4081/ejtm.2017.6479 SN - 2037-7460 VL - 27 IS - 3 SP - 152 EP - 159 PB - Unipress CY - Padova ER - TY - JOUR A1 - Hoff, Marko A1 - Schaefer, Laura A1 - Heinke, Nancy A1 - Bittmann, Frank T1 - Report on adaptive force, a specific neuromuscular function JF - European journal of translational myology KW - Adaptive Force KW - isometric-eccentric force KW - muscle action KW - pneumatic force measuring system Y1 - 2015 U6 - https://doi.org/10.4081/ejtm.2015.5183 SN - 2037-7452 SN - 2037-7460 VL - 25 IS - 3 SP - 183 EP - 189 PB - PAGEPress CY - Pavia ER -