TY - JOUR A1 - Wollenberger, Ursula A1 - Jin, Wen A1 - Bernhardt, Rita A1 - Lehmann, Claudia A1 - Stöcklein, Walter F. M. A1 - Brigelius-Flohé, Regina A1 - Scheller, Frieder W. T1 - Funktionalisierung von Elektroden für den direkten heterogenen Elektrotransfer Y1 - 1998 ER - TY - JOUR A1 - Wollenberger, Ursula A1 - Drungiliene, A. A1 - Stöcklein, Walter F. M. A1 - Kulys, J. A1 - Scheller, Frieder W. T1 - Direct electrocatalytic determination of dissolved peroxidases Y1 - 1996 ER - TY - JOUR A1 - Stöllner, Daniela A1 - Stöcklein, Walter F. M. A1 - Scheller, Frieder W. A1 - Warsinke, Axel T1 - Membrane-immobilized haptoglobin as affinity matrix for a hemoglobin-A1c-immunosensor Y1 - 2002 ER - TY - JOUR A1 - Stöcklein, Walter F. M. A1 - Warsinke, Axel A1 - Scheller, Frieder W. T1 - Organic solvent modified enzyme-liked immunoassay for the detection of triazine herbicides Y1 - 1997 ER - TY - JOUR A1 - Stöcklein, Walter F. M. A1 - Warsinke, Axel A1 - Micheel, Burkhard A1 - Kempter, Gerhard A1 - Höhne, Wolfgang A1 - Scheller, Frieder W. T1 - Diphenylurea hapten sensing with a monoclonal antibody and its Fab fragment : kinetic and thermodynamic investigations Y1 - 1998 ER - TY - JOUR A1 - Stöcklein, Walter F. M. A1 - Warsinke, Axel A1 - Micheel, Burkhard A1 - Höhne, Wolfgang A1 - Woller, Jochen A1 - Kempter, Gerhard A1 - Scheller, Frieder W. T1 - Characterization of a monoclonal antibody and its Fab fragment against diphenylurea hapten with BIA Y1 - 1998 SN - 3-8154-3540-4 ER - TY - JOUR A1 - Stöcklein, Walter F. M. A1 - Warsinke, Axel A1 - Micheel, Burkhard A1 - Höhne, Wolfgang A1 - Woller, Jochen A1 - Kempter, Gerhard A1 - Scheller, Frieder W. T1 - Detection of diphenylurea derivatives with biospecific interaction analysis (BIA) : Kinetic investigations Y1 - 1997 ER - TY - JOUR A1 - Stöcklein, Walter F. M. A1 - Scheller, Frieder W. A1 - Abuknesha, Rhamadan T1 - Effects of organic solvents on semicontinuous immunochemical detection of coumarin derivatives Y1 - 1995 ER - TY - JOUR A1 - Stöcklein, Walter F. M. A1 - Scheller, Frieder W. T1 - Enzymes and antibodies in organic media : analytical applications Y1 - 1997 ER - TY - JOUR A1 - Stöcklein, Walter F. M. A1 - Scheller, Frieder W. T1 - Einsatz von Enzymen und Antikörpern in organischen Lösungsmitteln Y1 - 1995 ER - TY - JOUR A1 - Stöcklein, Walter F. M. A1 - Scheller, Frieder W. T1 - Laccase : a marker enzyme for solvent modified immunoassays Y1 - 1996 ER - TY - JOUR A1 - Stöcklein, Walter F. M. A1 - Rohde, M. A1 - Scharte, Gudrun A1 - Behrsing, Olaf A1 - Warsinke, Axel A1 - Micheel, Burkhard A1 - Scheller, Frieder W. T1 - Sensitive detection of triazine and phenylurea pesticides in pure organic solvent by enzyme linked immunsorbent assay (ELISA): stabilities, solubilities and sensitives Y1 - 2000 ER - TY - JOUR A1 - Stöcklein, Walter F. M. A1 - Makower, Alexander A1 - Bier, Frank Fabian A1 - Scheller, Frieder W. T1 - Enzyme sensors and enzyme amplifification systems Y1 - 1997 ER - TY - JOUR A1 - Stöcklein, Walter F. M. A1 - Behrsing, Olaf A1 - Scharte, Gudrun A1 - Micheel, Burkhard A1 - Benkert, Alexander A1 - Schössler, W. A1 - Warsinke, Axel A1 - Scheller, Frieder W. T1 - Enzyme kinetic assays with surface plasmon resonance (BIAcore) based on competition between enzyme and creatinine antibody Y1 - 2000 ER - TY - JOUR A1 - Stöcklein, Walter F. M. T1 - Molecule-detective BT - Molekül-Detektive : Biosensoren N2 - Biosensors are analytical devices incorporating biological material (receptor) intimately associated with or integrated within a physicochernical transducer. Advantages are the high selectivity for analyte detection. Examples given comprise the very successful commercial blood glucose biosensors made for the self-control by the diabetic patients. Other biosensors are part of an analytic system, including the sensor chips Of surface plasmon resonance or interferometry based devices, piezoelectric or reflectometric sensors capable of direct measurement of mass changes, and thermometric and other reagentless sensors. The development of nanotubes-based devices allows for significant enhancment of the signal-to-noise ratio of the biosensors. A milestone on the way towards miniaturization and parallelization of biosensors is the recently developed and prize-winning electronic DNA chip Y1 - 2006 ER - TY - JOUR A1 - Stöcklein, Walter F. M. T1 - Biosensoren für die direkte vor-Ort Überwachung von Umwelt-Schadstoffen Y1 - 2000 ER - TY - JOUR A1 - Stech, Marlitt A1 - Merk, Helmut A1 - Schenk, Jörg A. A1 - Stöcklein, Walter F. M. A1 - Wüstenhagen, Doreen Anja A1 - Micheel, Burkhard A1 - Duschl, Claus A1 - Bier, Frank Fabian A1 - Kubick, Stefan T1 - Production of functional antibody fragments in a vesicle-based eukaryotic cell-free translation system JF - Journal of biotechnology N2 - Cell-free protein synthesis is of increasing interest for the rapid and high-throughput synthesis of many proteins, in particular also antibody fragments. In this study, we present a novel strategy for the production of single chain antibody fragments (scFv) in a eukaryotic in vitro translation system. This strategy comprises the cell-free expression, isolation and label-free interaction analysis of a model antibody fragment synthesized in two differently prepared insect cell lysates. These lysates contain translocationally active microsomal structures derived from the endoplasmic reticulum (ER), allowing for posttranslational modifications of cell-free synthesized proteins. Both types of these insect cell lysates enable the synthesis and translocation of scFv into ER-derived vesicles. However, only the one that has a specifically adapted redox potential yields functional active antibody fragments. We have developed a new methodology for the isolation of functional target proteins based on the translocation of cell-free produced scFv into microsomal structures and subsequent collection of protein-enriched vesicles. Antibody fragments that have been released from these vesicles are shown to be well suited for label-free binding studies. Altogether, these results show the potential of insect cell lysates for the production, purification and selection of antibody fragments in an easy-to-handle and time-saving manner. KW - Cell-free KW - In vitro translation KW - Single chain antibody (scFv) KW - Insect lysate KW - Surface plasmon resonance Y1 - 2012 U6 - https://doi.org/10.1016/j.jbiotec.2012.08.020 SN - 0168-1656 VL - 164 IS - 2 SP - 220 EP - 231 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Schenk, Jörg A. A1 - Sellrie, Frank A1 - Böttger, Volker A1 - Micheel, Burkhard A1 - Stöcklein, Walter F. M. T1 - Generation and application of a fluorescein-specific single chain antibody N2 - A recombinant single chain antibody fragment (designated scDE1) of the murine monoclonal anti-fluorescein antibody B13-DE1 was generated using the original hybridoma cells as source for the variable antibody heavy and light chain (VH and VL) genes. After cloning the variable genes into a phage vector a functional antibody fragment was selected by phage display panning. Recombinant antibody could be expressed as phage antibody and as soluble single chain antibody in Escherichia coli. High yield of scDE1 could also be detected in bacterial culture supernatant. The scDE1 showed the same binding specificity as the parental monoclonal antibody, i.e. it bound fluorescein, fluorescein derivatives and a fluorescein peptide mimotope. Surface plasmon resonance revealed a K(D) of 19 nM for the scDE1 compared to 0.7 nM for the monoclonal antibody. The isolated soluble scDE1 could easily be conjugated to horseradish peroxidase which allowed the use of the conjugate as universal indicator for the detection of fluorescein-labelled proteins in different immunoassays. Detection of hCG in urine was performed as a model system using scDE1. In addition to E. coli the scFv genes could also be transferred and expressed in eukaryotic cells. Finally, we generated HEK293 cells expressing the scDE1 at the cell surface. Y1 - 2007 UR - http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6VRJ-4P3DY33- 1&_user=1584062&_rdoc=1&_fmt=&_orig=search&_sort=d&view=c&_acct=C000053886&_version=1&_urlVersion=0&_userid=1584062&md5=e 4 ER - TY - JOUR A1 - Sass, Stephan A1 - Stöcklein, Walter F. M. A1 - Klevesath, Anja A1 - Hurpin, Jeanne A1 - Menger, Marcus A1 - Hille, Carsten T1 - Binding affinity data of DNA aptamers for therapeutic anthracyclines from microscale thermophoresis and surface plasmon resonance spectroscopy JF - The analyst : the analytical journal of the Royal Society of Chemistry N2 - Anthracyclines like daunorubicin (DRN) and doxorubicin (DOX) play an undisputed key role in cancer treatment, but their chronic administration can cause severe side effects. For precise anthracycline analytical systems, aptamers are preferable recognition elements. Here, we describe the detailed characterisation of a single-stranded DNA aptamer DRN-10 and its truncated versions for DOX and DRN detection. Binding affinities were determined from surface plasmon resonance (SPR) and microscale thermophoresis (MST) and combined with conformational data from circular dichroism (CD). Both aptamers displayed similar nanomolar binding affinities to DRN and DOX, even though their rate constants differed as shown by SPR recordings. SPR kinetic data unravelled a two-state reaction model including a 1 : 1 binding and a subsequent conformational change of the binding complex. This model was supported by CD spectra. In addition, the dissociation constants determined with MST were always lower than that from SPR, and especially for the truncated aptamer they differed by two orders of magnitude. This most probably reflects the methodological difference, namely labelling for MST vs. immobilisation for SPR. From CD recordings, we suggested a specific G-quadruplex as structural basis for anthracycline binding. We concluded that the aptamer DRN-10 is a promising recognition element for anthracycline detection systems and further selected aptamers can be also characterised with the combined methodological approach presented here. Y1 - 2019 U6 - https://doi.org/10.1039/c9an01247h SN - 0003-2654 SN - 1364-5528 VL - 144 IS - 20 SP - 6064 EP - 6073 PB - Royal Society of Chemistry CY - Cambridge ER - TY - JOUR A1 - Pieper-Fürst, U. A1 - Kleuser, U. A1 - Stöcklein, Walter F. M. A1 - Warsinke, Axel A1 - Scheller, Frieder W. T1 - Detection of subicomolar concentrations of human matrix metalloproteinase-2 by an optical biosensor N2 - We describe in this paper the development of a one-step sandwich assay for the highly sensitive and fast detection of human matrix metalloproteinase (MMP)-2 (EC 3.4.24.24), using surface plasmon resonance (SPR). For the assay, two ligands were selected: monoclonal anti-MMP-2 antibody Ab-2 and the tissue inhibitor of metalloproteinases (TIMP)-2. They were chosen on the basis of (1) their affinities to MMP-2, (2) the efficiency of immobilization to the sensor chip, (3) the efficiency of adsorption to colloidal gold, and (4) the stability of these protein-coated gold particles. The assay included mixing of MMP-2 with antibody Ab-2 adsorbed to colloidal gold with a diameter of about 20 rim and injection into the flowcell of the SPR instrument containing immobilized TIMP-2. By using colloidal gold particles an amplification factor of 114 and a detection limit of 0.5 pM for MMP-2 were obtained. The precision of the assay was high even at low analyte concentrations, the standard deviation being 8.3% for five determinations of 1 pM MMP- 2. No significant binding was observed with the structurally related MMP-9. The assay is far more sensitive and faster than commonly used methods for MMP-2 detection. As TIMP-bound MMP-2 is not detected by this method, the assay can be applied for measuring free MMP-2, reflecting the imbalance of free and inhibitor-bound enzyme in various pathological situations. (C) 2004 Elsevier Inc. All rights reserved Y1 - 2004 ER -