TY - JOUR A1 - Nguyen Le Duy, A1 - Nguyen Viet Du, A1 - Heidbüchel, Ingo A1 - Meyer, Hanno A1 - Weiler, Markus A1 - Merz, Bruno A1 - Apel, Heiko T1 - Identification of groundwater mean transit times of precipitation and riverbank infiltration by two-component lumped parameter models JF - Hydrological processes N2 - Groundwater transit time is an essential hydrologic metric for groundwater resources management. However, especially in tropical environments, studies on the transit time distribution (TTD) of groundwater infiltration and its corresponding mean transit time (mTT) have been extremely limited due to data sparsity. In this study, we primarily use stable isotopes to examine the TTDs and their mTTs of both vertical and horizontal infiltration at a riverbank infiltration area in the Vietnamese Mekong Delta (VMD), representative of the tropical climate in Asian monsoon regions. Precipitation, river water, groundwater, and local ponding surface water were sampled for 3 to 9 years and analysed for stable isotopes (delta O-18 and delta H-2), providing a unique data set of stable isotope records for a tropical region. We quantified the contribution that the two sources contributed to the local shallow groundwater by a novel concept of two-component lumped parameter models (LPMs) that are solved using delta O-18 records. The study illustrates that two-component LPMs, in conjunction with hydrological and isotopic measurements, are able to identify subsurface flow conditions and water mixing at riverbank infiltration systems. However, the predictive skill and the reliability of the models decrease for locations farther from the river, where recharge by precipitation dominates, and a low-permeable aquitard layer above the highly permeable aquifer is present. This specific setting impairs the identifiability of model parameters. For river infiltration, short mTTs (<40 weeks) were determined for sites closer to the river (<200 m), whereas for the precipitation infiltration, the mTTs were longer (>80 weeks) and independent of the distance to the river. The results not only enhance the understanding of the groundwater recharge dynamics in the VMD but also suggest that the highly complex mechanisms of surface-groundwater interaction can be conceptualized by exploiting two-component LPMs in general. The model concept could thus be a powerful tool for better understanding both the hydrological functioning of mixing processes and the movement of different water components in riverbank infiltration systems. KW - bank infiltration KW - groundwater KW - lumped parameter model KW - mean transit time KW - Mekong Delta KW - stable isotopes Y1 - 2019 U6 - https://doi.org/10.1002/hyp.13549 SN - 0885-6087 SN - 1099-1085 VL - 33 IS - 24 SP - 3098 EP - 3118 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Angermann, Lisa A1 - Jackisch, Conrad A1 - Allroggen, Niklas A1 - Sprenger, Matthias A1 - Zehe, Erwin A1 - Tronicke, Jens A1 - Weiler, Markus A1 - Blume, Theresa T1 - Form and function in hillslope hydrology: characterization of subsurface flow based on response observations JF - Hydrology and earth system sciences : HESS N2 - The phrase form and function was established in architecture and biology and refers to the idea that form and functionality are closely correlated, influence each other, and co-evolve. We suggest transferring this idea to hydrological systems to separate and analyze their two main characteristics: their form, which is equivalent to the spatial structure and static properties, and their function, equivalent to internal responses and hydrological behavior. While this approach is not particularly new to hydrological field research, we want to employ this concept to explicitly pursue the question of what information is most advantageous to understand a hydrological system. We applied this concept to subsurface flow within a hillslope, with a methodological focus on function: we conducted observations during a natural storm event and followed this with a hillslope-scale irrigation experiment. The results are used to infer hydrological processes of the monitored system. Based on these findings, the explanatory power and conclusiveness of the data are discussed. The measurements included basic hydrological monitoring methods, like piezometers, soil moisture, and discharge measurements. These were accompanied by isotope sampling and a novel application of 2-D time-lapse GPR (ground-penetrating radar). The main finding regarding the processes in the hillslope was that preferential flow paths were established quickly, despite unsaturated conditions. These flow paths also caused a detectable signal in the catchment response following a natural rainfall event, showing that these processes are relevant also at the catchment scale. Thus, we conclude that response observations (dynamics and patterns, i.e., indicators of function) were well suited to describing processes at the observational scale. Especially the use of 2-D time-lapse GPR measurements, providing detailed subsurface response patterns, as well as the combination of stream-centered and hillslope-centered approaches, allowed us to link processes and put them in a larger context. Transfer to other scales beyond observational scale and generalizations, however, rely on the knowledge of structures (form) and remain speculative. The complementary approach with a methodological focus on form (i.e., structure exploration) is presented and discussed in the companion paper by Jackisch et al. (2017). Y1 - 2017 U6 - https://doi.org/10.5194/hess-21-3727-2017 SN - 1027-5606 SN - 1607-7938 VL - 21 SP - 3727 EP - 3748 PB - Copernicus CY - Göttingen ER - TY - JOUR A1 - Weiler, Markus A1 - Menzel, Christoph A1 - Pertsch, Thomas A1 - Alaee, Rasoul A1 - Rockstuhl, Carsten A1 - Pacholski, Claudia T1 - Bottom-Up Fabrication of Hybrid Plasmonic Sensors: Gold-Capped Hydrogel Microspheres Embedded in Periodic Metal Hole Arrays JF - Polymer : the international journal for the science and technology of polymers N2 - The high potential of bottom-up fabrication strategies for realizing sophisticated optical sensors combining the high sensitivity of a surface plasmon resonance with the exceptional properties of stimuli-responsive hydrogel is demonstrated. The sensor is composed of a periodic hole array in a gold film whose holes are filled with gold-capped poly(N-isoproyl-acrylamide) (polyNIPAM) microspheres. The production of this sensor relies on a pure chemical approach enabling simple, time-efficient, and cost-efficient preparation of sensor platforms covering areas of cm(2). The transmission spectrum of this plasmonic sensor shows a strong interaction between propagating surface plasmon polaritons at the metal film surface and localized surface plasmon resonance of the gold cap on top of the polyNIPAM microspheres. Computer simulations support this experimental observation. These interactions lead to distinct changes in the transmission spectrum, which allow for the simultaneous, sensitive optical detection of refractive index changes in the surrounding medium and the swelling state of the embedded polyNIPAM microsphere under the gold cap. The volume of the polyNIPAM microsphere located underneath the gold cap can be changed by certain stimuli such as temperature, pH, ionic strength, and distinct molecules bound to the hydrogel matrix facilitating the detection of analytes which do not change the refractive index of the surrounding medium significantly. KW - bottom-up KW - hydrogel KW - hole array KW - sensor KW - surface plasmon resonance Y1 - 2016 U6 - https://doi.org/10.1021/acsami.6b08636 SN - 1944-8244 VL - 8 SP - 26392 EP - 26399 PB - American Chemical Society CY - Washington ER -