TY - GEN A1 - De Souza Silveira, Raul A1 - Carlsohn, Anja A1 - Langen, Georg A1 - Mayer, Frank A1 - Scharhag-Rosenberger, Friederike T1 - Reliability and day-to-day variability of peak fat oxidation during treadmill ergometry T2 - Postprints der Universität Potsdam : Humanwissenschaftliche Reihe N2 - Background: Exercising at intensities where fat oxidation rates are high has been shown to induce metabolic benefits in recreational and health-oriented sportsmen. The exercise intensity (Fat peak ) eliciting peak fat oxidation rates is therefore of particular interest when aiming to prescribe exercise for the purpose of fat oxidation and related metabolic effects. Although running and walking are feasible and popular among the target population, no reliable protocols are available to assess Fat peak as well as its actual velocity (V PFO ) during treadmill ergometry. Our purpose was therefore, to assess the reliability and day-to-day variability of V PFO and Fat peak during treadmill ergometry running. Methods: Sixteen recreational athletes (f = 7, m = 9; 25 ± 3 y; 1.76 ± 0.09 m; 68.3 ± 13.7 kg; 23.1 ± 2.9 kg/m 2 ) performed 2 different running protocols on 3 different days with standardized nutrition the day before testing. At day 1, peak oxygen uptake (VO 2peak ) and the velocities at the aerobic threshold (V LT ) and respiratory exchange ratio (RER) of 1.00 (V RER ) were assessed. At days 2 and 3, subjects ran an identical submaximal incremental test (Fat-peak test) composed of a 10 min warm-up (70 % V LT ) followed by 5 stages of 6 min with equal increments (stage 1 = V LT , stage 5 = V RER ). Breath-by-breath gas exchange data was measured continuously and used to determine fat oxidation rates. A third order polynomial function was used to identify V PFO and subsequently Fat peak . The reproducibility and variability of variables was verified with an int raclass correlation coef ficient (ICC), Pearson ’ s correlation coefficient, coefficient of variation (CV) an d the mean differences (bias) ± 95 % limits of agreement (LoA). Results: ICC, Pearson ’ s correlation and CV for V PFO and Fat peak were 0.98, 0.97, 5.0 %; and 0.90, 0.81, 7.0 %, respectively. Bias ± 95 % LoA was − 0.3 ± 0.9 km/h for V PFO and − 2±8%ofVO 2peak for Fat peak. Conclusion: In summary, relative and absolute reliability indicators for V PFO and Fat peak were found to be excellent. The observed LoA may now serve as a basis for future training prescriptions, although fat oxidation rates at prolonged exercise bouts at this intensity still need to be investigated. T3 - Zweitveröffentlichungen der Universität Potsdam : Humanwissenschaftliche Reihe - 423 KW - peak fat oxidation KW - reliability KW - variability KW - running KW - treadmill ergometry Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-407334 IS - 423 ER -