TY - JOUR A1 - Cywinski, Piotr J. A1 - Pietraszkiewicz, Marek A1 - Maciejczyk, Michal A1 - Gorski, Krzysztof A1 - Hammann, Tommy A1 - Liermann, Konstanze A1 - Paulke, Bernd-Reiner A1 - Löhmannsröben, Hans-Gerd T1 - Total protein concentration quantification using nanobeads with a new highly luminescent terbium(III) complex JF - RSC Advances N2 - Total protein concentration (TPC) is a key parameter in many biochemical experiments and its quantification is often necessary for isolation, separation, and analysis of proteins. A sensitive and rapid nanobead-based TPC quantification assay based on Forster Resonance Energy Transfer (FRET) has been developed. A new, highly luminescent Tb(III) complex has been synthesised and applied as donor in this FRET assay with an organic dye (Cy5) as acceptor. FRET-induced changes in luminescence have been investigated both at donor and acceptor emission wavelength using time-resolved luminescence spectroscopy with time-gated detection. In the assay, the Tb(III) complex and fine-tuned polyglycidyl methacrylate (PGMA) nanobeads ensure that an improvement in sensitivity and background reduction is achieved. Using 40 nm large PGMA nanobeads loaded with the Tb(III) complex, it is possible to determine TPC down to 50 ng mL(-1) in just 10 minutes. Through specific assay components the sensitivity has been improved when compared to existing nanobead-based assays and to currently known commercial methods. Additionally, the assay is relatively insensitive to the presence of contaminants, such as non-ionic detergents commonly found in biological samples. Due to no need for any centrifugal steps, this mix-and-measure bioassay can easily be implemented into routine TPC quantification protocols in biochemical laboratories. Y1 - 2016 U6 - https://doi.org/10.1039/c6ra23207h SN - 2046-2069 VL - 6 SP - 115068 EP - 115073 PB - Royal Society of Chemistry CY - Cambridge ER - TY - JOUR A1 - Riebe, Daniel A1 - Eder, Alexander A1 - Ritschel, Thomas A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd A1 - Beil, Andreas A1 - Blaschke, Michael A1 - Ludwig, Thomas T1 - Atmospheric pressure chemical ionization of explosives induced by soft X-radiation in ion mobility spectrometry: mass spectrometric investigation of the ionization reactions of drift gasses, dopants and alkyl nitrates JF - Journal of mass spectrometr N2 - A promising replacement for the radioactive sources commonly encountered in ion mobility spectrometers is a miniaturized, energy-efficient photoionization source that produce the reactant ions via soft X-radiation (2.8 keV). In order to successfully apply the photoionization source, it is imperative to know the spectrum of reactant ions and the subsequent ionization reactions leading to the detection of analytes. To that end, an ionization chamber based on the photoionization source that reproduces the ionization processes in the ion mobility spectrometer and facilitates efficient transfer of the product ions into a mass spectrometer was developed. Photoionization of pure gasses and gas mixtures containing air, N-2, CO2 and N2O and the dopant CH2Cl2 is discussed. The main product ions of photoionization are identified and compared with the spectrum of reactant ions formed by radioactive and corona discharge sources on the basis of literature data. The results suggest that photoionization by soft X-radiation in the negative mode is more selective than the other sources. In air, adduct ions of O-2 - with H2O and CO2 were exclusively detected. Traces of CO2 impact the formation of adduct ions of O-2 - and Cl -(upon addition of dopant) and are capable of suppressing them almost completely at high CO2 concentrations. Additionally, the ionization products of four alkyl nitrates (ethylene glycol dinitrate, nitroglycerin, erythritol tetranitrate and pentaerythritol tetranitrate) formed by atmospheric pressure chemical ionization induced by X-ray photoionization in different gasses (air, N-2 and N2O) and dopants (CH2Cl2, C2H5Br and CH3I) are investigated. The experimental studies are complemented by density functional theory calculations of the most important adduct ions of the alkyl nitrates (M) used for their spectrometric identification. In addition to the adduct ions [M + NO3](-) and [M + Cl](-), adduct ions such as [M + N2O2](-), [M + Br](-) and [M+ I](-) were detected, and their gas-phase structures and energetics are investigated by density functional theory calculations. Copyright (C) 2016 John Wiley & Sons, Ltd. KW - ion mobility spectrometry KW - mass spectrometry KW - explosives KW - X-ray KW - photoionization KW - alkyl nitrates Y1 - 2016 U6 - https://doi.org/10.1002/jms.3784 SN - 1076-5174 SN - 1096-9888 VL - 51 SP - 566 EP - 577 PB - Wiley-Blackwell CY - Hoboken ER - TY - JOUR A1 - Khadem, S. M. J. A1 - Hille, Carsten A1 - Löhmannsröben, Hans-Gerd A1 - Sokolov, Igor M. T1 - What information is contained in the fluorescence correlation spectroscopy curves, and where JF - Physical review : E, Statistical, nonlinear and soft matter physics Y1 - 2016 U6 - https://doi.org/10.1103/PhysRevE.94.022407 SN - 2470-0045 SN - 2470-0053 VL - 94 PB - American Physical Society CY - College Park ER - TY - JOUR A1 - Villatoro, José Andrés A1 - Zühlke, Martin A1 - Riebe, Daniel A1 - Riedel, Jens A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd T1 - IR-MALDI ion mobility spectrometry JF - Analytical and bioanalytical chemistry : a merger of Fresenius' journal of analytical chemistry and Analusis N2 - The novel combination of infrared matrix-assisted laser dispersion and ionization (IR-MALDI) with ion mobility (IM) spectrometry makes it possible to investigate biomolecules in their natural environment, liquid water. As an alternative to an ESI source, the IR-MALDI source was implemented in an in-house-developed ion mobility (IM) spectrometer. The release of ions directly from an aqueous solution is based on a phase explosion, induced by the absorption of an IR laser pulse (lambda = 2.94 mu m, 6 ns pulse width), which disperses the liquid as nano- and micro-droplets. The prerequisites for the application of IR-MALDI-IM spectrometry as an analytical method are narrow analyte ion signal peaks for a high spectrometer resolution. This can only be achieved by improving the desolvation of ions. One way to full desolvation is to give the cluster ions sufficient time to desolvate. Two methods for achieving this are studied: the implementation of an additional drift tube, as in ESI-IM-spectrometry, and the delayed extraction of the ions. As a result of this optimization procedure, limits of detection between 5 nM and 2.5 mu M as well as linear dynamic ranges of 2-3 orders of magnitude were obtained for a number of substances. The ability of this method to analyze simple mixtures is illustrated by the separation of two different surfactant mixtures. KW - Ion mobility spectrometry KW - IR-MALDI KW - Laser Y1 - 2016 U6 - https://doi.org/10.1007/s00216-016-9739-x SN - 1618-2642 SN - 1618-2650 VL - 408 SP - 6259 EP - 6268 PB - Springer CY - Heidelberg ER - TY - JOUR A1 - Villatoro, José Andrés A1 - Zühlke, Martin A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Weber, Marcus A1 - Riedel, Jens A1 - Löhmannsröben, Hans-Gerd T1 - IR-MALDI ion mobility spectrometry: physical source characterization and application as HPLC detector JF - International journal for ion mobility spectrometry : official publication of the International Society for Ion Mobility Spectrometry N2 - Infrared matrix-assisted laser dispersion and ionization (IR-MALDI) in combination with ion mobility (IM) spectrometry enables the direct analysis of biomolecules in aqueous solution. The release of ions directly from an aqueous solution is based on a phase explosion, induced by the absorption of an IR laser pulse, which disperses the liquid as vapor, nano-and micro-droplets. The ionization process is characterized initially by a broad spatial distribution of the ions, which is a result of complex fluid dynamics and desolvation kinetics. These processes have a profound effect on the shape and width of the peaks in the IM spectra. In this work, the transport of ions by the phase explosion-induced shockwave could be studied independently from the transport by the electric field. The shockwave-induced mean velocities of the ions at different time scales were determined through IM spectrometry and shadowgraphy. The results show a deceleration of the ions from 118 m.s(-1) at a distance of 400 mu m from the liquid surface to 7.1 m.s(-1) at a distance of 10 mm, which is caused by a pile-up effect. Furthermore, the desolvation kinetics were investigated and a first-order desolvation constant of 325 +/- 50 s(-1) was obtained. In the second part, the IR-MALDI-IM spectrometer is used as an HPLC detector for the two-dimensional separation of a pesticide mixture. KW - Ion mobility spectrometry KW - IR-MALDI KW - Shadowgraphy KW - Laser KW - Imaging KW - HPLC Y1 - 2016 U6 - https://doi.org/10.1007/s12127-016-0208-1 SN - 1435-6163 SN - 1865-4584 VL - 19 SP - 197 EP - 207 PB - Springer CY - Heidelberg ER - TY - JOUR A1 - Zühlke, Martin A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd A1 - Andreotti, Sandro A1 - Reinert, Knut A1 - Zenichowski, Karl A1 - Diener, Marc T1 - High-performance liquid chromatography with electrospray ionization ion mobility spectrometry: Characterization, data management, and applications JF - Journal of separation science N2 - The combination of high-performance liquid chromatography and electrospray ionization ion mobility spectrometry facilitates the two-dimensional separation of complex mixtures in the retention and drift time plane. The ion mobility spectrometer presented here was optimized for flow rates customarily used in high-performance liquid chromatography between 100 and 1500 mu L/min. The characterization of the system with respect to such parameters as the peak capacity of each time dimension and of the 2D spectrum was carried out based on a separation of a pesticide mixture containing 24 substances. While the total ion current chromatogram is coarsely resolved, exhibiting coelutions for a number of compounds, all substances can be separately detected in the 2D plane due to the orthogonality of the separations in retention and drift dimensions. Another major advantage of the ion mobility detector is the identification of substances based on their characteristic mobilities. Electrospray ionization allows the detection of substances lacking a chromophore. As an example, the separation of a mixture of 18 amino acids is presented. A software built upon the free mass spectrometry package OpenMS was developed for processing the extensive 2D data. The different processing steps are implemented as separate modules which can be arranged in a graphic workflow facilitating automated processing of data. KW - Amino acids KW - Electrospray ionization KW - Ion mobility spectrometry KW - Pesticides KW - Two-dimensional separations Y1 - 2016 U6 - https://doi.org/10.1002/jssc.201600749 SN - 1615-9306 SN - 1615-9314 VL - 39 SP - 4756 EP - 4764 PB - Wiley-VCH CY - Weinheim ER -