TY - JOUR A1 - Zühlke, Martin A1 - Zenichowski, Karl A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd T1 - Subambient pressure electrospray ionization ion mobility spectrometry JF - International journal for ion mobility spectrometry : official publication of the International Society for Ion Mobility Spectrometry N2 - The pressure dependence of sheath gas assisted electrospray ionization (ESI) was investigated based on two complementary experimental setups, namely an ESI-ion mobility (IM) spectrometer and an ESI capillary - Faraday plate setup housed in an optically accessible vacuum chamber. The ESI-IM spectrometer is capable of working in the pressure range between 300 and 1000 mbar. Another aim was the assessment of the analytical capabilities of a subambient pressure ESI-IM spectrometer. The pressure dependence of ESI was characterized by imaging the electrospray and recording current-voltage (I-U) curves. Qualitatively different behavior was observed in both setups. While the current rises continuously with the voltage in the capillary-plate setup, a sharp increase of the current was measured in the IM spectrometer above a pressure-dependent threshold voltage. The different character can be attributed to the detection of different species in both experiments. In the capillary-plate experiment, a multitude of charged species are detected while only desolvated ions attribute to the IM spectrometer signal. This finding demonstrates the utility of IM spectrometry for the characterization of ESI, since in contrast to the capillary-plate setup, the release of ions from the electrospray droplets can be observed. The I-U curves change significantly with pressure. An important result is the reduction of the maximum current with decreasing pressure. The connected loss of ionization efficiency can be compensated by a more efficient transfer of ions in the IM spectrometer at increased E/N. Thus, similar limits of detection could be obtained at 500 mbar and 1 bar. KW - Ion mobility spectrometry KW - Electrospray ionization KW - Subambient pressure KW - Imaging Y1 - 2017 U6 - https://doi.org/10.1007/s12127-017-0215-x SN - 1435-6163 SN - 1865-4584 VL - 20 SP - 47 EP - 56 PB - Springer CY - Heidelberg ER - TY - JOUR A1 - Zühlke, Martin A1 - Sass, Stephan A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd T1 - Real-Time Reaction Monitoring of an Organic Multistep Reaction by Electrospray Ionization-Ion Mobility Spectrometry JF - ChemPlusChem N2 - The capability of electrospray ionization (ESI)-ion mobility (IM) spectrometry for reaction monitoring is assessed both as a stand-alone real-time technique and in combination with HPLC. A three-step chemical reaction, consisting of a Williamson ether synthesis followed by a hydrogenation and an N-alkylation step, is chosen for demonstration. Intermediates and products are determined with a drift time to mass-per-charge correlation. Addition of an HPLC column to the setup increases the separation power and allows the determination of further species. Monitoring of the intensities of the various species over the reaction time allows the detection of the end of reaction, determination of the rate-limiting step, observation of the system response in discontinuous processes, and optimization of the mass ratios of the starting materials. However, charge competition in ESI influences the quantitative detection of substances in the reaction mixture. Therefore, two different methods are investigated, which allow the quantification and investigation of reaction kinetics. The first method is based on the pre-separation of the compounds on an HPLC column and their subsequent individual detection in the ESI-IM spectrometer. The second method involves an extended calibration procedure, which considers charge competition effects and facilitates nearly real-time quantification. KW - electrospray ionization KW - HPLC KW - ion mobility spectrometry KW - reaction mechanisms KW - reaction monitoring Y1 - 2017 U6 - https://doi.org/10.1002/cplu.201700296 SN - 2192-6506 VL - 82 SP - 1266 EP - 1273 PB - Wiley-VCH CY - Weinheim ER - TY - THES A1 - Zühlke, Martin T1 - Elektrosprayionisation Ionenmobilitätsspektrometrie T1 - Electrospray ionization Ion mobility spectrometry BT - Entwicklung, Charakterisierung und Anwendung zur HPLC-Detektion und zum Reaktionsmonitoring BT - development, characterization and application for HPLC detection and reaction monitoring N2 - Die Elektrosprayionisation (ESI) ist eine der weitverbreitetsten Ionisationstechniken für flüssige Pro-ben in der Massen- und Ionenmobilitäts(IM)-Spektrometrie. Aufgrund ihrer schonenden Ionisierung wird ESI vorwiegend für empfindliche, komplexe Moleküle in der Biologie und Medizin eingesetzt. Überdies ist sie allerdings für ein sehr breites Spektrum an Substanzklassen anwendbar. Die IM-Spektrometrie wurde ursprünglich zur Detektion gasförmiger Proben entwickelt, die hauptsächlich durch radioaktive Quellen ionisiert werden. Sie ist die einzige analytische Methode, bei der Isomere in Echtzeit getrennt und über ihre charakteristische IM direkt identifiziert werden können. ESI wurde in den 90ger Jahren durch die Hill Gruppe in die IM-Spektrometrie eingeführt. Die Kombination wird bisher jedoch nur von wenigen Gruppen verwendet und hat deshalb noch ein hohes Entwick-lungspotential. Ein vielversprechendes Anwendungsfeld ist der Einsatz in der Hochleistungs-flüssigkeitschromatographie (HPLC) zur mehrdimensionalen Trennung. Heutzutage ist die HPLC die Standardmethode zur Trennung komplexer Proben in der Routineanalytik. HPLC-Trennungsgänge sind jedoch häufig langwierig und der Einsatz verschiedener Laufmittel, hoher Flussraten, von Puffern, sowie Laufmittelgradienten stellt hohe Anforderungen an die Detektoren. Die ESI-IM-Spektrometrie wurde in einigen Studien bereits als HPLC-Detektor eingesetzt, war dort bisher jedoch auf Flussratensplitting oder geringe Flussraten des Laufmittels beschränkt. In dieser kumulativen Doktorarbeit konnte daher erstmals ein ESI IM-Spektrometer als HPLC-Detektor für den Flussratenbereich von 200-1500 μl/min entwickelt werden. Anhand von fünf Publi-kationen wurden (1) über eine umfassende Charakterisierung die Eignung des Spektrometers als HPLC-Detektor festgestellt, (2) ausgewählte komplexe Trenngänge präsentiert und (3) die Anwen-dung zum Reaktionsmonitoring und (4, 5) mögliche Weiterentwicklungen gezeigt. Erfolgreich konnten mit dem selbst-entwickelten ESI IM-Spektrometer typische HPLC-Bedingungen wie Wassergehalte im Laufmittel von bis zu 90%, Pufferkonzentrationen von bis zu 10 mM, sowie Nachweisgrenzen von bis zu 50 nM erreicht werden. Weiterhin wurde anhand der komplexen Trennungsgänge (24 Pestizide/18 Aminosäuren) gezeigt, dass die HPLC und die IM-Spektrometrie eine hohe Orthogonalität besitzen. Eine effektive Peakkapazität von 240 wurde so realisiert. Auf der HPLC-Säule koeluierende Substanzen konnten über die Driftzeit getrennt und über ihre IM identifi-ziert werden, sodass die Gesamttrennzeiten erheblich minimiert werden konnten. Die Anwend-barkeit des ESI IM-Spektrometers zur Überwachung chemischer Synthesen wurde anhand einer dreistufigen Reaktion demonstriert. Es konnten die wichtigsten Edukte, Zwischenprodukte und Produkte aller Stufen identifiziert werden. Eine quantitative Auswertung war sowohl über eine kurze HPLC-Vortrennung als auch durch die Entwicklung eines eigenen Kalibrierverfahrens, welches die Ladungskonkurrenz bei ESI berücksichtigt, ohne HPLC möglich. Im zweiten Teil der Arbeit werden zwei Weiterentwicklungen des Spektrometers präsentiert. Eine Möglichkeit ist die Reduzierung des Drucks in den intermediären Bereich (300 - 1000 mbar) mit dem Ziel der Verringerung der benötigten Spannungen. Mithilfe von Streulichtbildern und Strom-Spannungs-Kurven wurden für geringe Drücke eine verminderte Freisetzung der Analyt-Ionen aus den Tropfen festgestellt. Die Verluste konnten jedoch über höhere elektrische Feldstärken ausgeglichen werden, sodass gleiche Nachweisgrenzen bei 500 mbar und bei 1 bar erreicht wurden. Die zweite Weiterentwicklung ist ein neuartiges Ionentors mit Pulsschaltung, welches eine Verdopplung der Auflösung auf bis zu R > 100 bei gleicher Sensitivität ermöglichte. Eine denkbare Anwendung im Bereich der Peptidanalytik wurde mit beachtlichen Auflösungen der Peptide von R = 90 gezeigt. N2 - Electrospray ionization (ESI) is one of the most widespread ionization techniques for liquid samples in mass and ion mobility (IM) spectrometry. Due to its gentle ionization, ESI is often used for sensitive, complex molecules in biology and medicine. However, it is also applicable to a wide range of substance classes. IM spectrometry was originally developed for the detection of gaseous samples, which are mainly ionized by radioactive sources. It is the only analytical method in which isomers can be separated in real time and directly identified by their characteristic IM. ESI was introduced to IM spectrometry by the Hill Group in the 90s. So far, the combination was only used by a limited number of groups and therefore there is still a large development potential. A highly promising field of application is highperformance liquid chromatography (HPLC) for multidimensional separations. At present, HPLC is the standard method for the separation of complex samples in routine analysis. However, HPLC separations are often time-consuming and the use of different solvents, high flow rates, buffers, as well as solvent gradients impose high demands on the detectors. ESI IM spectrometry was already used as an HPLC detector in a number of studies. However, these studies were restricted to splitting or low flow rates of the mobile phase. In this cumulative thesis, an ESI IM spectrometer was developed as an HPLC detector for the flow rate range of 200-1500 μl/min for the first time. Based on five publications, (1) the suitability of the spectrometer as an HPLC detector was comprehensively characterized, (2) selected complex separations are presented, and (3) the application to the reaction monitoring as well as (4, 5) possible further developments are shown. With the in-house developed ESI IM spectrometer, typical HPLC conditions such as water contents in the mobile phase of up to 90%, buffer concentrations of up to 10 mM, as well as detection limits of up to 50 nM, were achieved successfully. Furthermore, on the basis of a complex separation (24 pesticides/18 amino acids), it could be demonstrated that HPLC and IM spectrometry possess a high degree of orthogonality. An effective peak capacity of 240 was thus realized. Substances coeulating on the HPLC column could be separated in the drift time and were identified by their IM. Thus, the overall separation times could be significantly reduced. The applicability of the ESI IM spectrometer for the monitoring of chemical syntheses was demonstrated for a three-stage reaction. The main starting materials, intermediates and products of all stages could be identified. A quantitative evaluation was possible both by means of a short HPLC pre-separation as well as by a newly developed calibration procedure, which takes charge competition during ESI into account, without HPLC. In the second part of the thesis, two further developments of the spectrometer are presented. One possibility is a reduction of the pressure to the intermediate range (300 - 1000 mbar) with the aim of reducing the required voltages. With the help of scattered light images and current-voltage curves, a reduced release of analyte ions from the droplets was determined at low pressures. However, these losses could be compensated for by higher electric field strengths. Therefore, the same detection limits were achieved at 500 mbar and at 1 bar. The second development is a novel ion gate with pulse switching, which allows a doubling of the resolution up to R > 100 with equal sensitivity. A possible application in the field of peptide analysis was demonstrated, achieving a considerable resolutions of R = 90 for the peptides. KW - HPLC KW - HPLC KW - Ionenmobilitätsspektrometrie KW - Elektrosprayionisation KW - ion mobility spectrometry KW - electrospray ionization (ESI) Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-407452 ER - TY - JOUR A1 - Zhong, Qi A1 - Metwalli, Ezzeldin A1 - Rawolle, Monika A1 - Kaune, Gunar A1 - Bivigou Koumba, Achille Mayelle A1 - Laschewsky, Andre A1 - Papadakis, Christine M. A1 - Cubitt, Robert A1 - Wang, Jiping A1 - Müller-Buschbaum, Peter T1 - Vacuum induced dehydration of swollen poly(methoxy diethylene glycol acrylate) and polystyrene-block-poly(methoxy diethylene glycol acrylate)-block-polystyrene films probed by in-situ neutron reflectivity JF - Polymer : the international journal for the science and technology of polymers N2 - The isothermal vacuum-induced dehydration of thin films made of poly(methoxy diethylene glycol acrylate) (PMDEGA), which were swollen under ambient conditions, is studied. The dehydration behavior of the homopolymer film as well as of a nanostructured film of the amphiphilic triblock copolymer polystyrene-block-poly(methoxy diethylene glycol acrylate)-block-polystyrene, abbreviated as PS-b-PMDEGA-b-PS, are probed, and compared to the thermally induced dehydration behavior of such thin thermo-responsive films when they pass through their LCST-type coil-to globule collapse transition. The dehydration kinetics is followed by in-situ neutron reflectivity measurements. Contrast results from the use of deuterated water. Water content and film thickness are significantly reduced during the process, which can be explained by Schott second order kinetics theory for both films. The water content of the dehydrated equilibrium state from this model is very close to the residual water content obtained from the final static measurements, indicating that residual water still remains in the film even after prolonged exposure to the vacuum. In the PS-b-PMDEGA-b-PS film that shows micro-phase separation, the hydrophobic PS domains modify the dehydration process by hindering the water removal, and thus retarding dehydration by about 30%. Whereas residual water remains tightly bound in the PMDEGA domains, water is completely removed from the PS domains of the block copolymer film. (C) 2017 Elsevier Ltd. All rights reserved. KW - Dehydration KW - Vacuum drying KW - In-situ neutron reflectivity Y1 - 2017 U6 - https://doi.org/10.1016/j.polymer.2017.07.066 SN - 0032-3861 SN - 1873-2291 VL - 124 SP - 263 EP - 273 PB - Elsevier CY - Oxford ER - TY - JOUR A1 - Zhang, Weiyi A1 - Willa, Christoph A1 - Sun, Jian-Ke A1 - Guterman, Ryan A1 - Taubert, Andreas A1 - Yuan, Jiayin T1 - Polytriazolium poly(ionic liquid) bearing triiodide anions: Synthesis, basic properties and electrochemical behaviors JF - Polymer : the international journal for the science and technology of polymers N2 - 4-Methyl-1-vinyl-1,2,4-triazolium triiodide ionic liquid and its polymer poly(4-methyl-1-vinyl-1,2,4-triazolium) triiodide were prepared for the first time from their iodide precursors via the reaction of iodide (I-) with elemental iodine (I-2). The change from iodide to triiodide (I-3(-)) was found to introduce particular variations in the physical properties of these two compounds, including lower melting point/glass transition temperature and altered solubility. The compounds were characterized by single-crystal X-ray diffraction, elemental analysis, and their electrochemical properties examined in solution and in the solid-state. Compared with their iodide analogues, the triiodide salts exhibited lower electrical impedance and higher current in the cyclic voltammetry. We found that poly(4-methyl-1,2,4-triazolium triiodide) was proven to be a promising solid polymer electrolyte candidate. (C) 2017 Elsevier Ltd. All rights reserved. KW - Poly(ionic liquid) KW - Solid polymer electrolyte KW - Grotthuss mechanism KW - Triiodide "network" Y1 - 2017 U6 - https://doi.org/10.1016/j.polymer.2017.07.059 SN - 0032-3861 SN - 1873-2291 VL - 124 SP - 246 EP - 251 PB - Elsevier CY - Oxford ER - TY - THES A1 - Zhang, Weiyi T1 - Functional Poly(ionic liquid) Materials based on Poly(1,2,4-triazolium)s Y1 - 2017 ER - TY - JOUR A1 - Zhang, Shuhao A1 - Bisterfeld, Carolin A1 - Bramski, Julia A1 - Vanparijs, Nane A1 - De Geest, Bruno G. A1 - Pietruszka, Jörg A1 - Böker, Alexander A1 - Reinicke, Stefan T1 - Biocatalytically Active Thin Films via Self-Assembly of 2-Deoxy-D-ribose-5-phosphate Aldolase-Poly(N-isopropylacrylamide) Conjugates JF - Bioconjugate chemistry N2 - 2-Deoxy-D-ribose-5-phosphate aldolase (DERA) is a biocatalyst that is capable of converting acetaldehyde and a second aldehyde as acceptor into enantiomerically pure mono- and diyhydroxyaldehydes, which are important structural motifs in a number of pharmaceutically active compounds. However, substrate as well as product inhibition requires a more-sophisticated process design for the synthesis of these motifs. One way to do so is to the couple aldehyde conversion with transport processes, which, in turn, would require an immobilization of the enzyme within a thin film that can be deposited on a membrane support. Consequently, we developed a fabrication process for such films that is based on the formation of DERA-poly(N-isopropylacrylamide) conjugates that are subsequently allowed to self-assemble at an air-water interface to yield the respective film. In this contribution, we discuss the conjugation conditions, investigate the interfacial properties of the conjugates, and, finally, demonstrate a successful film formation under the preservation of enzymatic activity. Y1 - 2017 U6 - https://doi.org/10.1021/acs.bioconjchem.7b00645 SN - 1043-1802 VL - 29 IS - 1 SP - 104 EP - 116 PB - American Chemical Society CY - Washington ER - TY - GEN A1 - Zehbe, Kerstin A1 - Kollosche, Matthias A1 - Lardong, Sebastian A1 - Kelling, Alexandra A1 - Schilde, Uwe A1 - Taubert, Andreas T1 - Ionogels based on poly(methyl methacrylate) and metal-containing ionic liquids BT - correlation between structure and mechanical and electrical properties N2 - Ionogels (IGs) based on poly(methyl methacrylate) (PMMA) and the metal-containing ionic liquids (ILs) bis-1-butyl-3-methlimidazolium tetrachloridocuprate(II), tetrachloride cobaltate(II), and tetrachlorido manganate(II) have been synthesized and their mechanical and electrical properties have been correlated with their microstructure. Unlike many previous examples, the current IGs show a decreasing stability in stress-strain experiments on increasing IL fractions. The conductivities of the current IGs are lower than those observed in similar examples in the literature. Both effects are caused by a two-phase structure with micrometer-sized IL-rich domains homogeneously dispersed an IL-deficient continuous PMMA phase. This study demonstrates that the IL-polymer miscibility and the morphology of the IGs are key parameters to control the (macroscopic) properties of IGs. T3 - Zweitveröffentlichungen der Universität Potsdam : Mathematisch-Naturwissenschaftliche Reihe - 361 KW - microstructure KW - ionogels KW - ionic liquids KW - phase separation KW - mechanical properties KW - ionic conductivity Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-400607 ER - TY - JOUR A1 - You, Zewang A1 - Behl, Marc A1 - Löwenberg, Candy A1 - Lendlein, Andreas T1 - pH-sensitivity and conformation change of the n-terminal methacrylated peptide VK20 JF - MRS advances : a journal of the Materials Research Society (MRS) N2 - N-terminal methacrylation of peptide MAXI, which is capable of conformational changes variation of the pH, results in a peptide, named VK20. Increasing the reactivity of this terminal group enables further coupling reactions or chemical modifications of the peptidc. However, this end group functionalization may influence the ability of confonnational changes of VK20; as well as its properties. In this paper; the influence of pH on the transition between random coil and beta-sheet conformation of VK20; including the transition kinetics, were investigated. At pH values of 9 and higher, the kinetics beta-sheet formation increased tor VK(2 0, compared to MAXI. The self-assembly into beta-sheets recognized by the formation of a physically crosslinked gel was furthermore indicated by a significant increase of G. An increase in pH (from 9 to 9.5) led to a faster gelation of the peptide VK20. Simultaneously, G was increased from 460 +/- 70 Pa (at pH 9) to 1520 +/- 180 Pa (at pH 9.5). At the nanoscale, the gel showed a highly interconnected fibrillar/network structure with uniform fibril widths of approximately 3.4 +/- 0.5 nm (N=30). The recovery of the peptide conformation back to random coil resulted in the dissolution of the gel; whereby the kinetics of the recovery depended on the pH. Conclusively, the ability of MAXI to undergo confommtional changes was not affected by N-terminal methacrylation whereas the kinetics of pH-sensitive beta-sheet formations has been increased. Y1 - 2017 U6 - https://doi.org/10.1557/adv.2017.491 SN - 2059-8521 VL - 2 SP - 2571 EP - 2579 PB - Cambridge University Press CY - Cambridge ER - TY - THES A1 - You, Zewang T1 - Conformational transition of peptide-functionalized cryogels enabling shape-memory capability Y1 - 2017 ER -