TY - JOUR A1 - Zühlke, Martin A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd A1 - Zenichowski, Karl A1 - Diener, Marc A1 - Linscheid, Michael W. T1 - An electrospray ionization-ion mobility spectrometer as detector for high-performance liquid chromatography JF - European journal of mass spectrometry N2 - The application of electrospray ionization (ESI) ion mobility (IM) spectrometry on the detection end of a high-performance liquid chromatograph has been a subject of study for some time. So far, this method has been limited to low flow rates or has required splitting of the liquid flow. This work presents a novel concept of an ESI source facilitating the stable operation of the spectrometer at flow rates between 10 mu L min(-1) and 1500 mu L min(-1) without flow splitting, advancing the T-cylinder design developed by Kurnin and co-workers. Flow rates eight times faster than previously reported were achieved because of a more efficient dispersion of the liquid at increased electrospray voltages combined with nebulization by a sheath gas. Imaging revealed the spray operation to be in a rotationally symmetric multijet-mode. The novel ESI-IM spectrometer tolerates high water contents (<= 90%) and electrolyte concentrations up to 10 mM, meeting another condition required of high-performance liquid chromatography (HPLC) detectors. Limits of detection of 50 nM for promazine in the positive mode and 1 mu M for 1,3-dinitrobenzene in the negative mode were established. Three mixtures of reduced complexity (five surfactants, four neuroleptics, and two isomers) were separated in the millisecond regime in stand-alone operation of the spectrometer. Separations of two more complex mixtures (five neuroleptics and 13 pesticides) demonstrate the application of the spectrometer as an HPLC detector. The examples illustrate the advantages of the spectrometer over the established diode array detector, in terms of additional IM separation of substances not fully separated in the retention time domain as well as identification of substances based on their characteristic IMs. KW - ESI KW - IMS KW - HPLC KW - spray imaging KW - neuroleptics KW - pesticides KW - surfactants Y1 - 2015 U6 - https://doi.org/10.1255/ejms.1367 SN - 1469-0667 SN - 1751-6838 VL - 21 IS - 3 SP - 391 EP - 402 PB - WeltTrends CY - Sussex ER - TY - JOUR A1 - Riebe, Daniel A1 - Eder, Alexander A1 - Ritschel, Thomas A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd A1 - Beil, Andreas A1 - Blaschke, Michael A1 - Ludwig, Thomas T1 - Atmospheric pressure chemical ionization of explosives induced by soft X-radiation in ion mobility spectrometry: mass spectrometric investigation of the ionization reactions of drift gasses, dopants and alkyl nitrates JF - Journal of mass spectrometr N2 - A promising replacement for the radioactive sources commonly encountered in ion mobility spectrometers is a miniaturized, energy-efficient photoionization source that produce the reactant ions via soft X-radiation (2.8 keV). In order to successfully apply the photoionization source, it is imperative to know the spectrum of reactant ions and the subsequent ionization reactions leading to the detection of analytes. To that end, an ionization chamber based on the photoionization source that reproduces the ionization processes in the ion mobility spectrometer and facilitates efficient transfer of the product ions into a mass spectrometer was developed. Photoionization of pure gasses and gas mixtures containing air, N-2, CO2 and N2O and the dopant CH2Cl2 is discussed. The main product ions of photoionization are identified and compared with the spectrum of reactant ions formed by radioactive and corona discharge sources on the basis of literature data. The results suggest that photoionization by soft X-radiation in the negative mode is more selective than the other sources. In air, adduct ions of O-2 - with H2O and CO2 were exclusively detected. Traces of CO2 impact the formation of adduct ions of O-2 - and Cl -(upon addition of dopant) and are capable of suppressing them almost completely at high CO2 concentrations. Additionally, the ionization products of four alkyl nitrates (ethylene glycol dinitrate, nitroglycerin, erythritol tetranitrate and pentaerythritol tetranitrate) formed by atmospheric pressure chemical ionization induced by X-ray photoionization in different gasses (air, N-2 and N2O) and dopants (CH2Cl2, C2H5Br and CH3I) are investigated. The experimental studies are complemented by density functional theory calculations of the most important adduct ions of the alkyl nitrates (M) used for their spectrometric identification. In addition to the adduct ions [M + NO3](-) and [M + Cl](-), adduct ions such as [M + N2O2](-), [M + Br](-) and [M+ I](-) were detected, and their gas-phase structures and energetics are investigated by density functional theory calculations. Copyright (C) 2016 John Wiley & Sons, Ltd. KW - ion mobility spectrometry KW - mass spectrometry KW - explosives KW - X-ray KW - photoionization KW - alkyl nitrates Y1 - 2016 U6 - https://doi.org/10.1002/jms.3784 SN - 1076-5174 SN - 1096-9888 VL - 51 SP - 566 EP - 577 PB - Wiley-Blackwell CY - Hoboken ER - TY - JOUR A1 - Riebe, Daniel A1 - Zühlke, Martin A1 - Zenichowski, Karl A1 - Beitz, Toralf A1 - Dosche, Carsten A1 - Löhmannsröben, Hans-Gerd T1 - Characterization of rhodamine 6G release in electrospray ionization by means of spatially resolved fluorescence spectroscopy JF - Zeitschrift für physikalische Chemie : international journal of research in physical chemistry and chemical physics N2 - In the present work, the density distribution of rhodamine 6G ions (R6G) in the gas phase and the droplets of an electrospray plume was studied by spatial and spectral imaging. The intention is to contribute to the fundamental understanding of the release mechanism of gaseous R6G in the electrospray ionization (ESI) process. Furthermore, the influence of ESI-parameters on the release efficiency of R6G, e. g. solvent flow, R6G and salt concentration were examined via direct fluorescence imaging of R6G. A solvent-shift of the fluorescence maximum,lambda(max) = 555 nm in methanolic solution and lambda(max) = 505 nm in gas phase, allows the discrimination between solvated and gaseous R6G. Two experimental setups were used for our measurements. In the first experiment, the R6G fluorescence and the light scattered from the spray plume were imaged in two spatial dimensions using a tunable wavelength filter. The second experiment was designed for obtaining 1-dimensional spatially resolved emission spectra of the spray. Here, the intensity distribution of solvated and gaseous R6G as well as scattered light (lambda = 355 nm) were measured simultaneously. The results show the distribution of gaseous R6G in the plane, orthogonal to the ESI capillary, decreasing slightly towards the spray center and showing maxima at the cone margins. The distribution of gaseous R6G confirms the preferred release of gaseous ions from nano-droplets, indicating the ion evaporation model (IEM) to be the dominating release mechanism. Up to now, only a few fluorescence spectra of ionic compounds in the gas phase were published because the measurement of emission spectra of mass-selected ions in an ion trap is experimentally challenging. The fluorescence spectrum of gaseous lucigenin at atmospheric pressure is reported for the first time. This spectrum of lucigenin in the gas phase exhibits a blue shift of about Delta lambda = 10 nm in comparison to the corresponding spectrum in methanol. KW - Fluorescence KW - Electrospray Ionization KW - Rhodamine 6G KW - Gaseous Ions KW - Lucigenin Y1 - 2011 U6 - https://doi.org/10.1524/zpch.2011.0149 SN - 0942-9352 VL - 225 IS - 9-10 SP - 1055 EP - 1072 PB - De Gruyter Oldenbourg CY - München ER - TY - JOUR A1 - Erler, Alexander A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd A1 - Grothusheitkamp, Daniela A1 - Kunz, Thomas A1 - Methner, Frank-Jürgen T1 - Characterization of volatile metabolites formed by molds on barley by mass and ion mobility spectrometry JF - Journal of mass spectrometr N2 - The contamination of barley by molds on the field or in storage leads to the spoilage of grain and the production of mycotoxins, which causes major economic losses in malting facilities and breweries. Therefore, on-site detection of hidden fungus contaminations in grain storages based on the detection of volatile marker compounds is of high interest. In this work, the volatile metabolites of 10 different fungus species are identified by gas chromatography (GC) combined with two complementary mass spectrometric methods, namely, electron impact (EI) and chemical ionization at atmospheric pressure (APCI)-mass spectrometry (MS). The APCI source utilizes soft X-radiation, which enables the selective protonation of the volatile metabolites largely without side reactions. Nearly 80 volatile or semivolatile compounds from different substance classes, namely, alcohols, aldehydes, ketones, carboxylic acids, esters, substituted aromatic compounds, alkenes, terpenes, oxidized terpenes, sesquiterpenes, and oxidized sesquiterpenes, could be identified. The profiles of volatile and semivolatile metabolites of the different fungus species are characteristic of them and allow their safe differentiation. The application of the same GC parameters and APCI source allows a simple method transfer from MS to ion mobility spectrometry (IMS), which permits on-site analyses of grain stores. Characterization of IMS yields limits of detection very similar to those of APCI-MS. Accordingly, more than 90% of the volatile metabolites found by APCI-MS were also detected in IMS. In addition to different fungus genera, different species of one fungus genus could also be differentiated by GC-IMS. KW - APCI KW - fungus KW - gas chromatography KW - ion mobility spectrometry KW - mass KW - spectrometry KW - mold KW - soft X-ray Y1 - 2020 U6 - https://doi.org/10.1002/jms.4501 SN - 1076-5174 SN - 1096-9888 VL - 55 IS - 5 SP - 1 EP - 10 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Wojcik, Michal A1 - Brinkmann, Pia A1 - Zdunek, Rafał A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Merk, Sven A1 - Cieslik, Katarzyna A1 - Mory, David A1 - Antonczak, Arkadiusz T1 - Classification of copper minerals by handheld laser-induced breakdown spectroscopy and nonnegative tensor factorisation JF - Sensors N2 - Laser-induced breakdown spectroscopy (LIBS) analysers are becoming increasingly common for material classification purposes. However, to achieve good classification accuracy, mostly noncompact units are used based on their stability and reproducibility. In addition, computational algorithms that require significant hardware resources are commonly applied. For performing measurement campaigns in hard-to-access environments, such as mining sites, there is a need for compact, portable, or even handheld devices capable of reaching high measurement accuracy. The optics and hardware of small (i.e., handheld) devices are limited by space and power consumption and require a compromise of the achievable spectral quality. As long as the size of such a device is a major constraint, the software is the primary field for improvement. In this study, we propose a novel combination of handheld LIBS with non-negative tensor factorisation to investigate its classification capabilities of copper minerals. The proposed approach is based on the extraction of source spectra for each mineral (with the use of tensor methods) and their labelling based on the percentage contribution within the dataset. These latent spectra are then used in a regression model for validation purposes. The application of such an approach leads to an increase in the classification score by approximately 5% compared to that obtained using commonly used classifiers such as support vector machines, linear discriminant analysis, and the k-nearest neighbours algorithm. KW - LIBS KW - NTF KW - HALS KW - classification KW - copper minerals Y1 - 2020 U6 - https://doi.org/10.3390/s20185152 SN - 1424-8220 VL - 20 IS - 18 PB - MDPI CY - Basel ER - TY - GEN A1 - Riebe, Daniel A1 - Erler, Alexander A1 - Brinkmann, Pia A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd A1 - Gebbers, Robin T1 - Comparison of Calibration Approaches in Laser-Induced Breakdown Spectroscopy for Proximal Soil Sensing in Precision Agriculture T2 - Postprints der Universität Potsdam Mathematisch-Naturwissenschaftliche Reihe N2 - The lack of soil data, which are relevant, reliable, affordable, immediately available, and sufficiently detailed, is still a significant challenge in precision agriculture. A promising technology for the spatial assessment of the distribution of chemical elements within fields, without sample preparation is laser-induced breakdown spectroscopy (LIBS). Its advantages are contrasted by a strong matrix dependence of the LIBS signal which necessitates careful data evaluation. In this work, different calibration approaches for soil LIBS data are presented. The data were obtained from 139 soil samples collected on two neighboring agricultural fields in a quaternary landscape of northeast Germany with very variable soils. Reference analysis was carried out by inductively coupled plasma optical emission spectroscopy after wet digestion. The major nutrients Ca and Mg and the minor nutrient Fe were investigated. Three calibration strategies were compared. The first method was based on univariate calibration by standard addition using just one soil sample and applying the derived calibration model to the LIBS data of both fields. The second univariate model derived the calibration from the reference analytics of all samples from one field. The prediction is validated by LIBS data of the second field. The third method is a multivariate calibration approach based on partial least squares regression (PLSR). The LIBS spectra of the first field are used for training. Validation was carried out by 20-fold cross-validation using the LIBS data of the first field and independently on the second field data. The second univariate method yielded better calibration and prediction results compared to the first method, since matrix effects were better accounted for. PLSR did not strongly improve the prediction in comparison to the second univariate method. T3 - Zweitveröffentlichungen der Universität Potsdam : Mathematisch-Naturwissenschaftliche Reihe - 786 KW - laser-induced breakdown spectroscopy KW - LIBS KW - proximal soil sensing KW - soil nutrients KW - elemental composition Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-440079 SN - 1866-8372 IS - 786 ER - TY - JOUR A1 - Riebe, Daniel A1 - Erler, Alexander A1 - Brinkmann, Pia A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd A1 - Gebbers, Robin T1 - Comparison of Calibration Approaches in Laser-Induced Breakdown Spectroscopy for Proximal Soil Sensing in Precision Agriculture JF - Sensors N2 - The lack of soil data, which are relevant, reliable, affordable, immediately available, and sufficiently detailed, is still a significant challenge in precision agriculture. A promising technology for the spatial assessment of the distribution of chemical elements within fields, without sample preparation is laser-induced breakdown spectroscopy (LIBS). Its advantages are contrasted by a strong matrix dependence of the LIBS signal which necessitates careful data evaluation. In this work, different calibration approaches for soil LIBS data are presented. The data were obtained from 139 soil samples collected on two neighboring agricultural fields in a quaternary landscape of northeast Germany with very variable soils. Reference analysis was carried out by inductively coupled plasma optical emission spectroscopy after wet digestion. The major nutrients Ca and Mg and the minor nutrient Fe were investigated. Three calibration strategies were compared. The first method was based on univariate calibration by standard addition using just one soil sample and applying the derived calibration model to the LIBS data of both fields. The second univariate model derived the calibration from the reference analytics of all samples from one field. The prediction is validated by LIBS data of the second field. The third method is a multivariate calibration approach based on partial least squares regression (PLSR). The LIBS spectra of the first field are used for training. Validation was carried out by 20-fold cross-validation using the LIBS data of the first field and independently on the second field data. The second univariate method yielded better calibration and prediction results compared to the first method, since matrix effects were better accounted for. PLSR did not strongly improve the prediction in comparison to the second univariate method. KW - laser-induced breakdown spectroscopy KW - LIBS KW - proximal soil sensing KW - soil nutrients KW - elemental composition Y1 - 2019 U6 - https://doi.org/10.3390/s19235244 SN - 1424-8220 VL - 19 IS - 23 PB - MDPI CY - Basel ER - TY - JOUR A1 - Laudien, Robert A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd T1 - Detection of explosive related nitroaromatic compounds (ERNC) by laser-based ion mobility spectrometry Y1 - 2008 SN - 978-0-8194-7348-6 ER - TY - JOUR A1 - Rethfeldt, Nina A1 - Brinkmann, Pia A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Köllner, Nicole A1 - Altenberger, Uwe A1 - Löhmannsröben, Hans-Gerd T1 - Detection of Rare Earth Elements in Minerals and Soils by Laser-Induced Breakdown Spectroscopy (LIBS) Using Interval PLS JF - Minerals N2 - The numerous applications of rare earth elements (REE) has lead to a growing global demand and to the search for new REE deposits. One promising technique for exploration of these deposits is laser-induced breakdown spectroscopy (LIBS). Among a number of advantages of the technique is the possibility to perform on-site measurements without sample preparation. Since the exploration of a deposit is based on the analysis of various geological compartments of the surrounding area, REE-bearing rock and soil samples were analyzed in this work. The field samples are from three European REE deposits in Sweden and Norway. The focus is on the REE cerium, lanthanum, neodymium and yttrium. Two different approaches of data analysis were used for the evaluation. The first approach is univariate regression (UVR). While this approach was successful for the analysis of synthetic REE samples, the quantitative analysis of field samples from different sites was influenced by matrix effects. Principal component analysis (PCA) can be used to determine the origin of the samples from the three deposits. The second approach is based on multivariate regression methods, in particular interval PLS (iPLS) regression. In comparison to UVR, this method is better suited for the determination of REE contents in heterogeneous field samples. View Full-Text KW - LIBS KW - rare earth elements KW - minerals KW - PCA KW - iPLS regression Y1 - 2021 U6 - https://doi.org/10.3390/min11121379 SN - 2075-163X VL - 11 SP - 1 EP - 17 PB - MDPI CY - Basel, Schweiz ER - TY - GEN A1 - Rethfeldt, Nina A1 - Brinkmann, Pia A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Köllner, Nicole A1 - Altenberger, Uwe A1 - Löhmannsröben, Hans-Gerd T1 - Detection of Rare Earth Elements in Minerals and Soils by Laser-Induced Breakdown Spectroscopy (LIBS) Using Interval PLS T2 - Zweitveröffentlichungen der Universität Potsdam : Mathematisch-Naturwissenschaftliche Reihe N2 - The numerous applications of rare earth elements (REE) has lead to a growing global demand and to the search for new REE deposits. One promising technique for exploration of these deposits is laser-induced breakdown spectroscopy (LIBS). Among a number of advantages of the technique is the possibility to perform on-site measurements without sample preparation. Since the exploration of a deposit is based on the analysis of various geological compartments of the surrounding area, REE-bearing rock and soil samples were analyzed in this work. The field samples are from three European REE deposits in Sweden and Norway. The focus is on the REE cerium, lanthanum, neodymium and yttrium. Two different approaches of data analysis were used for the evaluation. The first approach is univariate regression (UVR). While this approach was successful for the analysis of synthetic REE samples, the quantitative analysis of field samples from different sites was influenced by matrix effects. Principal component analysis (PCA) can be used to determine the origin of the samples from the three deposits. The second approach is based on multivariate regression methods, in particular interval PLS (iPLS) regression. In comparison to UVR, this method is better suited for the determination of REE contents in heterogeneous field samples. View Full-Text T3 - Zweitveröffentlichungen der Universität Potsdam : Mathematisch-Naturwissenschaftliche Reihe - 1254 KW - LIBS KW - rare earth elements KW - minerals KW - PCA KW - iPLS regression Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-557469 SN - 1866-8372 SP - 1 EP - 17 PB - Universitätsverlag Potsdam CY - Potsdam ER -