TY - GEN A1 - De Souza Silveira, Raul A1 - Carlsohn, Anja A1 - Langen, Georg A1 - Mayer, Frank A1 - Scharhag-Rosenberger, Friederike T1 - Reliability and day-to-day variability of peak fat oxidation during treadmill ergometry T2 - Postprints der Universität Potsdam : Humanwissenschaftliche Reihe N2 - Background: Exercising at intensities where fat oxidation rates are high has been shown to induce metabolic benefits in recreational and health-oriented sportsmen. The exercise intensity (Fat peak ) eliciting peak fat oxidation rates is therefore of particular interest when aiming to prescribe exercise for the purpose of fat oxidation and related metabolic effects. Although running and walking are feasible and popular among the target population, no reliable protocols are available to assess Fat peak as well as its actual velocity (V PFO ) during treadmill ergometry. Our purpose was therefore, to assess the reliability and day-to-day variability of V PFO and Fat peak during treadmill ergometry running. Methods: Sixteen recreational athletes (f = 7, m = 9; 25 ± 3 y; 1.76 ± 0.09 m; 68.3 ± 13.7 kg; 23.1 ± 2.9 kg/m 2 ) performed 2 different running protocols on 3 different days with standardized nutrition the day before testing. At day 1, peak oxygen uptake (VO 2peak ) and the velocities at the aerobic threshold (V LT ) and respiratory exchange ratio (RER) of 1.00 (V RER ) were assessed. At days 2 and 3, subjects ran an identical submaximal incremental test (Fat-peak test) composed of a 10 min warm-up (70 % V LT ) followed by 5 stages of 6 min with equal increments (stage 1 = V LT , stage 5 = V RER ). Breath-by-breath gas exchange data was measured continuously and used to determine fat oxidation rates. A third order polynomial function was used to identify V PFO and subsequently Fat peak . The reproducibility and variability of variables was verified with an int raclass correlation coef ficient (ICC), Pearson ’ s correlation coefficient, coefficient of variation (CV) an d the mean differences (bias) ± 95 % limits of agreement (LoA). Results: ICC, Pearson ’ s correlation and CV for V PFO and Fat peak were 0.98, 0.97, 5.0 %; and 0.90, 0.81, 7.0 %, respectively. Bias ± 95 % LoA was − 0.3 ± 0.9 km/h for V PFO and − 2±8%ofVO 2peak for Fat peak. Conclusion: In summary, relative and absolute reliability indicators for V PFO and Fat peak were found to be excellent. The observed LoA may now serve as a basis for future training prescriptions, although fat oxidation rates at prolonged exercise bouts at this intensity still need to be investigated. T3 - Zweitveröffentlichungen der Universität Potsdam : Humanwissenschaftliche Reihe - 423 KW - peak fat oxidation KW - reliability KW - variability KW - running KW - treadmill ergometry Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-407334 IS - 423 ER - TY - GEN A1 - Bisi-Balogun, Adebisi A1 - Cassel, Michael A1 - Mayer, Frank T1 - Reliability of various measurement stations for determining plantar fascia thickness and echogenicity N2 - This study aimed to determine the relative and absolute reliability of ultrasound (US) measurements of the thickness and echogenicity of the plantar fascia (PF) at different measurement stations along its length using a standardized protocol. Twelve healthy subjects (24 feet) were enrolled. The PF was imaged in the longitudinal plane. Subjects were assessed twice to evaluate the intra-rater reliability. A quantitative evaluation of the thickness and echogenicity of the plantar fascia was performed using Image J, a digital image analysis and viewer software. A sonography evaluation of the thickness and echogenicity of the PF showed a high relative reliability with an Intra class correlation coefficient of 0.88 at all measurement stations. However, the measurement stations for both the PF thickness and echogenicity which showed the highest intraclass correlation coefficient (ICCs) did not have the highest absolute reliability. Compared to other measurement stations, measuring the PF thickness at 3 cm distal and the echogenicity at a region of interest 1 cm to 2 cm distal from its insertion at the medial calcaneal tubercle showed the highest absolute reliability with the least systematic bias and random error. Also, the reliability was higher using a mean of three measurements compared to one measurement. To reduce discrepancies in the interpretation of the thickness and echogenicity measurements of the PF, the absolute reliability of the different measurement stations should be considered in clinical practice and research rather than the relative reliability with the ICC. T3 - Zweitveröffentlichungen der Universität Potsdam : Humanwissenschaftliche Reihe - 339 KW - plantar fascia KW - reliability KW - sonography KW - musculoskeletal Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-400615 ER - TY - GEN A1 - Malesza, Marta A1 - Ostaszewski, Paweł A1 - Büchner, Susanne A1 - Kaczmarek, Magdalena Claudia T1 - The adaptation of the Short Dark Triad personality measure BT - psychometric properties of a German sample T2 - Postprints der Universität Potsdam Humanwissenschaftliche Reihe N2 - This research was designed to adapt and investigate the psychometric properties of the Short Dark Triad measure (Jones and Paulhus Assessment, 21(1), 28-41, 2014) in a German sample within four studies (total N = 1463); the measure evaluates three personality dimensions: narcissism, psychopathy, and Machiavellianism. The structure of the instrument was analysed by Confirmatory Factor Analyses procedure. It indicated that the three-factor structure had the best fit to the data. Next, the Short Dark Triad measure was evaluated in terms of construct, convergent and discriminant validity, internal consistency (≥ .72), and test-retest reliability during a 4-week period (≥ .73). Concurrent validity of the SD3 was supported by relating its subscales to measures of the Big Five concept, aggression, and self-esteem. We concluded that the Short Dark Triad instrument presented high cross-language replicability. The use of this short inventory in the investigation of the Dark Triad personality model in the German language context is suggested. T3 - Zweitveröffentlichungen der Universität Potsdam : Humanwissenschaftliche Reihe - 555 KW - short dark triad KW - SD3 KW - adaptation KW - reliability KW - validity Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-432896 SN - 1866-8364 IS - 555 ER - TY - JOUR A1 - Mugele, Hendrik A1 - Plummer, Ashley A1 - Baritello, Omar A1 - Towe, Maggie A1 - Brecht, Pia A1 - Mayer, Frank T1 - Accuracy of training recommendations based on a treadmill multistage incremental exercise test JF - PLOS ONE N2 - Competitive runners will occasionally undergo exercise in a laboratory setting to obtain predictive and prescriptive information regarding their performance. The present research aimed to assess whether the physiological demands of lab-based treadmill running (TM) can simulate that of over-ground (OG) running using a commonly used protocol. Fifteen healthy volunteers with a weekly mileage of ≥ 20 km over the past 6 months and treadmill experience participated in this cross-sectional study. Two stepwise incremental tests until volitional exhaustion was performed in a fixed order within one week in an Outpatient Clinic research laboratory and outdoor athletic track. Running velocity (IATspeed), heart rate (IATHR) and lactate concentration at the individual anaerobic threshold (IATbLa) were primary endpoints. Additionally, distance covered (DIST), maximal heart rate (HRmax), maximal blood lactate concentration (bLamax) and rate of perceived exertion (RPE) at IATspeed were analyzed. IATspeed, DIST and HRmax were not statistically significantly different between conditions, whereas bLamax and RPE at IATspeed showed statistical significance (p < 0.05). Apart from RPE at IATspeed, IATspeed, DIST, HRmax and bLamax strongly correlate between conditions (r = 0.815–0.988). High reliability between conditions provides strong evidence to suggest that running on a treadmill are physiologically comparable to that of OG and that training recommendations and be made with assurance. KW - individual anaerobic threshold KW - lactate threshold KW - soccer players KW - performance KW - validity KW - reliability KW - runners Y1 - 2018 U6 - https://doi.org/10.1371/journal.pone.0204696 SN - 1932-6203 VL - 13 IS - 10 SP - 1 EP - 12 PB - PLOS CY - San Francisco ER - TY - GEN A1 - Mugele, Hendrik A1 - Plummer, Ashley A1 - Baritello, Omar A1 - Towe, Maggie A1 - Brecht, Pia A1 - Mayer, Frank T1 - Accuracy of training recommendations based on a treadmill multistage incremental exercise test T2 - Postprints der Universität Potsdam : Humanwissenschaftliche Reihe N2 - Competitive runners will occasionally undergo exercise in a laboratory setting to obtain predictive and prescriptive information regarding their performance. The present research aimed to assess whether the physiological demands of lab-based treadmill running (TM) can simulate that of over-ground (OG) running using a commonly used protocol. Fifteen healthy volunteers with a weekly mileage of ≥ 20 km over the past 6 months and treadmill experience participated in this cross-sectional study. Two stepwise incremental tests until volitional exhaustion was performed in a fixed order within one week in an Outpatient Clinic research laboratory and outdoor athletic track. Running velocity (IATspeed), heart rate (IATHR) and lactate concentration at the individual anaerobic threshold (IATbLa) were primary endpoints. Additionally, distance covered (DIST), maximal heart rate (HRmax), maximal blood lactate concentration (bLamax) and rate of perceived exertion (RPE) at IATspeed were analyzed. IATspeed, DIST and HRmax were not statistically significantly different between conditions, whereas bLamax and RPE at IATspeed showed statistical significance (p < 0.05). Apart from RPE at IATspeed, IATspeed, DIST, HRmax and bLamax strongly correlate between conditions (r = 0.815–0.988). High reliability between conditions provides strong evidence to suggest that running on a treadmill are physiologically comparable to that of OG and that training recommendations and be made with assurance. T3 - Zweitveröffentlichungen der Universität Potsdam : Humanwissenschaftliche Reihe - 477 KW - individual anaerobic threshold KW - lactate threshold KW - soccer players KW - performance KW - validity KW - reliability KW - runners Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-419697 SN - 1866-8364 IS - 477 ER -