TY - JOUR A1 - Ast, Sandra A1 - Fischer, Tobias A1 - Müller, Holger A1 - Mickler, Wulfhard A1 - Schwichtenberg, Mathias A1 - Rurack, Knut A1 - Holdt, Hans-Jürgen T1 - Integration of the 1,2,3-Triazole "Click" Motif as a potent signalling element in metal ion responsive fluorescent probes JF - Chemistry - a European journal N2 - In a systematic approach we synthesized a new series of fluorescent probes incorporating donoracceptor (D-A) substituted 1,2,3-triazoles as conjugative -linkers between the alkali metal ion receptor N-phenylaza-[18]crown-6 and different fluorophoric groups with different electron-acceptor properties (4-naphthalimide, meso-phenyl-BODIPY and 9-anthracene) and investigated their performance in organic and aqueous environments (physiological conditions). In the charge-transfer (CT) type probes 1, 2 and 7, the fluorescence is almost completely quenched by intramolecular CT (ICT) processes involving charge-separated states. In the presence of Na+ and K+ ICT is interrupted, which resulted in a lighting-up of the fluorescence in acetonitrile. Among the investigated fluoroionophores, compound 7, which contains a 9-anthracenyl moiety as the electron-accepting fluorophore, is the only probe which retains light-up features in water and works as a highly K+/Na+-selective probe under simulated physiological conditions. Virtually decoupled BODIPY-based 6 and photoinduced electron transfer (PET) type probes 35, where the 10-substituted anthracen-9-yl fluorophores are connected to the 1,2,3-triazole through a methylene spacer, show strong ion-induced fluorescence enhancement in acetonitrile, but not under physiological conditions. Electrochemical studies and theoretical calculations were used to assess and support the underlying mechanisms for the new ICT and PET 1,2,3-triazole fluoroionophores. KW - charge transfer KW - click chemistry KW - electron transfer KW - fluorescent probes KW - metal ions Y1 - 2013 U6 - https://doi.org/10.1002/chem.201201575 SN - 0947-6539 VL - 19 IS - 9 SP - 2990 EP - 3005 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Schwarze, Thomas A1 - Mertens, Monique A1 - Mueller, Peter A1 - Riemer, Janine A1 - Wessig, Pablo A1 - Holdt, Hans-Jürgen T1 - Highly K+-Selective Fluorescent Probes for Lifetime Sensing of K+ in Living Cells JF - Chemistry - a European journal N2 - The new K+-selective fluorescent probes 1 and 2 were obtained by Cu-I-catalyzed 1,3-dipolar azide alkyne cycloaddition (CuAAC) reactions of an alkyne-substituted [1,3]dioxolo[4,5-f][1,3]benzodioxole (DBD) ester fluorophore with azido-functionalized N-phenylaza-18-crown-6 ether and N-(o-isopropoxy) phenylaza-18-crown-6 ether, respectively. Probes 1 and 2 allow the detection of K+ in the presence of Na+ in water by fluorescence enhancement (2.2 for 1 at 2000mm K+ and 2.5 for 2 at 160mm K+). Fluorescence lifetime measurements in the absence and presence of K+ revealed bi-exponential decay kinetics with similar lifetimes, however with different proportions changing the averaged fluorescence decay times ((f(av))). For 1 a decrease of (f(av)) from 12.4 to 9.3ns and for 2 an increase from 17.8 to 21.8ns was observed. Variation of the substituent in ortho position of the aniline unit of the N-phenylaza-18-crown-6 host permits the modulation of the K-d value for a certain K+ concentration. For example, substitution of H in 1 by the isopropoxy group (2) decreased the K-d value from >300mm to 10mm. 2 was chosen for studying the efflux of K+ from human red blood cells (RBC). Upon addition of the Ca2+ ionophor ionomycin to a RBC suspension in a buffer containing Ca2+, the fluorescence of 2 slightly rose within 10min, however, after 120min a significant increase was observed. KW - electron transfer KW - fluorescence lifetime KW - fluorescent probes KW - living cells KW - potassium Y1 - 2017 U6 - https://doi.org/10.1002/chem.201704368 SN - 0947-6539 SN - 1521-3765 VL - 23 SP - 17186 EP - 17190 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Schwarze, Thomas A1 - Mueller, Holger A1 - Schmidt, Darya A1 - Riemer, Janine A1 - Holdt, Hans-Jürgen T1 - Design of Na+-Selective Fluorescent Probes: A Systematic Study of the Na+-Complex Stability and the Na+/K+ Selectivity in Acetonitrile and Water JF - Chemistry - a European journal N2 - There is a tremendous demand for highly Na+-selective fluoroionophores to monitor the top analyte Na+ in life science. Here, we report a systematic route to develop highly Na+/K+ selective fluorescent probes. Thus, we synthesized a set of fluoroionophores 1, 3, 4, 5, 8 and 9 (see Scheme 1) to investigate the Na+/K+ selectivity and Na(+-)complex stability in CH3CN and H2O. These Na+-probes bear different 15-crown-5 moieties to bind Na+ stronger than K+. In the set of the diethylaminocoumarin-substituted fluoroionophores 1-5, the following trend of fluorescence quenching 1 > 3 > 2 > 4 > 5 in CH3CN was observed. Therefore, the flexibility of the aza-15-crown-5 moieties in 1-4 determines the conjugation of the nitrogen lone pair with the aromatic ring. As a consequence, 1 showed in CH3CN the highest Na+-induced fluorescence enhancement (FE) by a factor of 46.5 and a weaker K+ induced FE of 3.7. The Na+-complex stability of 1-4 in CH3CN is enhanced in the following order of 2 > 4 > 3 > 1, assuming that the O-atom of the methoxy group in the ortho-position, as shown in 2, strengthened the Na+-complex formation. Furthermore, we found for the N( o-methoxyphenyl) aza-15-crown-5 substituted fluoroionophores 2, 8 and 9 in H2O, an enhanced Na+-complex stability in the following order 8 > 2 > 9 and an increased Na+/K+ selectivity in the reverse order 9 > 2 > 8. Notably, the Na+-induced FE of 8 (FEF = 10.9), 2 (FEF = 5.0) and 9 (FEF = 2.0) showed a similar trend associated with a decreased K+-induced FE [8 (FEF = 2.7) > 2 (FEF = 1.5) > 9 (FEF = 1.1)]. Here, the Na+-complex stability and Na+/K+ selectivity is also influenced by the fluorophore moiety. Thus, fluorescent probe 8 (K-d = 48 mm) allows high-contrast, sensitive, and selective Na+ measurements over extracellular K+ levels. A higher Na+/K+ selectivity showed fluorescent probe 9, but also a higher Kd value of 223 mm. Therefore, 9 is a suitable tool to measure Na+ concentrations up to 300 mm at a fluorescence emission of 614 nm. KW - crown compounds KW - fluorescence KW - fluorescent probes KW - potassium KW - sodium Y1 - 2017 U6 - https://doi.org/10.1002/chem.201605986 SN - 0947-6539 SN - 1521-3765 VL - 23 SP - 7255 EP - 7263 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Schwarze, Thomas A1 - Riemer, Janine A1 - Eidner, Sascha A1 - Holdt, Hans-Jürgen T1 - A Highly K+-Selective Two-Photon Fluorescent Probe JF - Chemistry - a European journal N2 - A highly K+-selective two-photon fluorescent probe for the in vitro monitoring of physiological K+ levels in the range of 1-100 mM is reported. The two-photon excited fluorescence (TPEF) probe shows a fluorescence enhancement (FE) by a factor of about three in the presence of 160 mM K+, independently of one-photon (OP, 430 nm) or two-photon (TP, 860 nm) excitation and comparable K+-induced FEs in the presence of competitive Na+ ions. The estimated dissociation constant (K-d) values in Na+-free solutions (K-d(OP)=(28 +/- 5) mM and K-d(TP)=(36 +/- 6) mM) and in combined K+/Na+ solutions (K-d(OP)=(38 +/- 8) mM and K-d(TP)=(46 +/- 25) mM) reflecting the high K+/Na+ selectivity of the fluorescent probe. The TP absorption cross-section (sigma(2PA)) of the TPEF probe+160 mMK(+) is 26 GM at 860 nm. Therefore, the TPEF probe is a suitable tool for the in vitro determination of K+. KW - click chemistry KW - fluorescence KW - fluorescent probes KW - potassium KW - two-photon Y1 - 2015 U6 - https://doi.org/10.1002/chem.201501473 SN - 0947-6539 SN - 1521-3765 VL - 21 IS - 32 SP - 11306 EP - 11310 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Schwarze, Thomas A1 - Riemer, Janine A1 - Müller, Holger A1 - John, Leonard A1 - Holdt, Hans-Jürgen A1 - Wessig, Pablo T1 - Na+ Selective Fluorescent Tools Based on Fluorescence Intensity Enhancements, Lifetime Changes, and on a Ratiometric Response JF - Chemistry - a European journal N2 - Over the years, we developed highly selective fluorescent probes for K+ in water, which show K+-induced fluorescence intensity enhancements, lifetime changes, or a ratiometric behavior at two emission wavelengths (cf. Scheme 1, K1-K4). In this paper, we introduce selective fluorescent probes for Na+ in water, which also show Na+ induced signal changes, which are analyzed by diverse fluorescence techniques. Initially, we synthesized the fluorescent probes 2, 4, 5, 6 and 10 for a fluorescence analysis by intensity enhancements at one wavelength by varying the Na+ responsive ionophore unit and the fluorophore moiety to adjust different K-d values for an intra- or extracellular Na+ analysis. Thus, we found that 2, 4 and 5 are Na+ selective fluorescent tools, which are able to measure physiologically important Na+ levels at wavelengths higher than 500 nm. Secondly, we developed the fluorescent probes 7 and 8 to analyze precise Na+ levels by fluorescence lifetime changes. Herein, only 8 (K-d=106 mm) is a capable fluorescent tool to measure Na+ levels in blood samples by lifetime changes. Finally, the fluorescent probe 9 was designed to show a Na+ induced ratiometric fluorescence behavior at two emission wavelengths. As desired, 9 (K-d=78 mm) showed a ratiometric fluorescence response towards Na+ ions and is a suitable tool to measure physiologically relevant Na+ levels by the intensity change of two emission wavelengths at 404 nm and 492 nm. KW - crown compounds KW - fluorescence lifetime KW - fluorescent probes KW - ratiometric KW - sodium Y1 - 2019 U6 - https://doi.org/10.1002/chem.201902536 SN - 0947-6539 SN - 1521-3765 VL - 25 IS - 53 SP - 12412 EP - 12422 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Schwarze, Thomas A1 - Schneider, Radu A1 - Riemer, Janine A1 - Holdt, Hans-Jürgen T1 - A Highly K+-Selective Fluorescent Probe - Tuning the K+-Complex Stability and the K+/Na+ Selectivity by Varying the Lariat-Alkoxy Unit of a Phenylaza[18]crown-6 Ionophore JF - Chemistry : an Asian journal ; an ACES journal N2 - A desirable goal is to synthesize easily accessible and highly K+/Na+-selective fluoroionophores to monitor physiological K+ levels in vitro and in vivo. Therefore, highly K+/Na+-selective ionophores have to be developed. Herein, we obtained in a sequence of only four synthetic steps a set of K+-responsive fluorescent probes 4, 5 and 6. In a systematic study, we investigated the influence of the alkoxy substitution in ortho position of the aniline moiety in -conjugated aniline-1,2,3-triazole-coumarin-fluoroionophores 4, 5 and 6 [R=MeO (4), EtO (5) and iPrO (6)] towards the K+-complex stability and K+/Na+ selectivity. The highest K+-complex stability showed fluoroionophore 4 with a dissociation constant K-d of 19mm, but the K-d value increases to 31mm in combined K+/Na+ solutions, indicating a poor K+/Na+ selectivity. By contrast, 6 showed even in the presence of competitive Na+ ions equal K-d values (K-d(K+)=45mm and K-d(K+/Na+)=45mm) and equal K+-induced fluorescence enhancement factors (FEFs=2.3). Thus, the fluorescent probe 6 showed an outstanding K+/Na+ selectivity and is a suitable fluorescent tool to measure physiological K+ levels in the range of 10-80mm in vitro. Further, the isopropoxy-substituted N-phenylaza[18]crown-6 ionophore in 6 is a highly K+-selective building block with a feasible synthetic route. KW - crown compounds KW - fluorescence KW - fluorescent probes KW - potassium KW - sodium Y1 - 2016 U6 - https://doi.org/10.1002/asia.201500956 SN - 1861-4728 SN - 1861-471X VL - 11 SP - 241 EP - 247 PB - Wiley-VCH CY - Weinheim ER -