TY - JOUR A1 - Raila, Jens A1 - Kawashima, Chiho A1 - Sauerwein, Helga A1 - Hülsmann, Nadine A1 - Knorr, Christoph A1 - Myamoto, Akio A1 - Schweigert, Florian J. T1 - Validation of blood vitamin A concentrations in cattle: comparison of a new cow-side test (iCheck™ FLUORO) with high-performance liquid chromatography (HPLC) JF - BMC veterinary research N2 - Background: Plasma concentration of retinol is an accepted indicator to assess the vitamin A (retinol) status in cattle. However, the determination of vitamin A requires a time consuming multi-step procedure, which needs specific equipment to perform extraction, centrifugation or saponification prior to high-performance liquid chromatography (HPLC). Methods: The concentrations of retinol in whole blood (n = 10), plasma (n = 132) and serum (n = 61) were measured by a new rapid cow-side test (iCheck™ FLUORO) and compared with those by HPLC in two independent laboratories in Germany (DE) and Japan (JP). Results: Retinol concentrations in plasma ranged from 0.033 to 0.532 mg/L, and in serum from 0.043 to 0.360 mg/L (HPLC method). No significant differences in retinol levels were observed between the new rapid cow-side test and HPLC performed in different laboratories (HPLC vs. iCheck™ FLUORO: 0.320 ± 0.047 mg/L vs. 0.333 ± 0.044 mg/L, and 0.240 ± 0.096 mg/L vs. 0.241 ± 0.069 mg/L, lab DE and lab JP, respectively). A similar comparability was observed when whole blood was used (HPLC vs. iCheck™ FLUORO: 0.353 ± 0.084 mg/L vs. 0.341 ± 0.064 mg/L). Results showed a good agreement between both methods based on correlation coefficients of r2 = 0.87 (P < 0.001) and Bland-Altman blots revealed no significant bias for all comparison. Conclusions: With the new rapid cow-side test (iCheck™ FLUORO) retinol concentrations in cattle can be reliably assessed within a few minutes and directly in the barn using even whole blood without the necessity of prior centrifugation. The ease of the application of the new rapid cow-side test and its portability can improve the diagnostic of vitamin A status and will help to control vitamin A supplementation in specific vitamin A feeding regimes such as used to optimize health status in calves or meat marbling in Japanese Black cattle. KW - Cattle KW - Vitamin A KW - Biomarker KW - Blood KW - Method comparison KW - Cow-side assay Y1 - 2017 U6 - https://doi.org/10.1186/s12917-017-1042-3 VL - 13 PB - BioMed Central CY - London ER - TY - CHAP A1 - Schweigert, Florian J. A1 - Raila, Jens A1 - Mothes, Ralf A1 - Frey, S. T1 - Point of care measurements of Vitamin A in blood and breast milk for low resource settings T2 - Annals of nutrition & metabolism : journal of nutrition, metabolic diseases and dietetics ; an official journal of International Union of Nutritional Sciences (IUNS) KW - Blood KW - Milk KW - Point of Care Assay and Vitamin A Y1 - 2011 SN - 0250-6807 VL - 58 IS - 2 SP - 382 EP - 382 PB - Karger CY - Basel ER - TY - JOUR A1 - Moser, Othmar A1 - Tschakert, Gerhard A1 - Müller, Alexander A1 - Groeschl, Werner A1 - Pieber, Thomas R. A1 - Obermayer-Pietsch, Barbara A1 - Koehler, Gerd A1 - Hofmann, Peter T1 - Exercise versus Moderate Continuous Exercise on Glucose Homeostasis and Hormone Response in Patients with Type 1 Diabetes Mellitus Using Novel Ultra-Long-Acting Insulin JF - PLoS one N2 - Introduction We investigated blood glucose (BG) and hormone response to aerobic high-intensity interval exercise (HIIE) and moderate continuous exercise (CON) matched for mean load and duration in type 1 diabetes mellitus (T1DM). Material and Methods Seven trained male subjects with T1DM performed a maximal incremental exercise test and HIIE and CON at 3 different mean intensities below (A) and above (B) the first lactate turn point and below the second lactate turn point (C) on a cycle ergometer. Subjects were adjusted to ultra-long-acting insulin Degludec (Tresiba/ Novo Nordisk, Denmark). Before exercise, standardized meals were administered, and short-acting insulin dose was reduced by 25% (A), 50% (B), and 75% (C) dependent on mean exercise intensity. During exercise, BG, adrenaline, noradrenaline, dopamine, cortisol, glucagon, and insulin-like growth factor-1, blood lactate, heart rate, and gas exchange variables were measured. For 24 h after exercise, interstitial glucose was measured by continuous glucose monitoring system. Results BG decrease during HIIE was significantly smaller for B (p = 0.024) and tended to be smaller for A and C compared to CON. No differences were found for post-exercise interstitial glucose, acute hormone response, and carbohydrate utilization between HIIE and CON for A, B, and C. In HIIE, blood lactate for A (p = 0.006) and B (p = 0.004) and respiratory exchange ratio for A (p = 0.003) and B (p = 0.003) were significantly higher compared to CON but not for C. Conclusion Hypoglycemia did not occur during or after HIIE and CON when using ultra-long-acting insulin and applying our methodological approach for exercise prescription. HIIE led to a smaller BG decrease compared to CON, although both exercises modes were matched for mean load and duration, even despite markedly higher peak workloads applied in HIIE. Therefore, HIIE and CON could be safely performed in T1DM. KW - Insulin KW - Exercise KW - Glucose KW - Hypoglycemia KW - Carbohydrates KW - Blood KW - Blood sugar KW - Heart rate Y1 - 2015 U6 - https://doi.org/10.1371/journal.pone.0136489 SN - 1932-6203 VL - 10 IS - 8 PB - Public Library of Science CY - Lawrence ER -