TY - GEN A1 - Bisi-Balogun, Adebisi A1 - Cassel, Michael A1 - Mayer, Frank T1 - Reliability of various measurement stations for determining plantar fascia thickness and echogenicity N2 - This study aimed to determine the relative and absolute reliability of ultrasound (US) measurements of the thickness and echogenicity of the plantar fascia (PF) at different measurement stations along its length using a standardized protocol. Twelve healthy subjects (24 feet) were enrolled. The PF was imaged in the longitudinal plane. Subjects were assessed twice to evaluate the intra-rater reliability. A quantitative evaluation of the thickness and echogenicity of the plantar fascia was performed using Image J, a digital image analysis and viewer software. A sonography evaluation of the thickness and echogenicity of the PF showed a high relative reliability with an Intra class correlation coefficient of 0.88 at all measurement stations. However, the measurement stations for both the PF thickness and echogenicity which showed the highest intraclass correlation coefficient (ICCs) did not have the highest absolute reliability. Compared to other measurement stations, measuring the PF thickness at 3 cm distal and the echogenicity at a region of interest 1 cm to 2 cm distal from its insertion at the medial calcaneal tubercle showed the highest absolute reliability with the least systematic bias and random error. Also, the reliability was higher using a mean of three measurements compared to one measurement. To reduce discrepancies in the interpretation of the thickness and echogenicity measurements of the PF, the absolute reliability of the different measurement stations should be considered in clinical practice and research rather than the relative reliability with the ICC. T3 - Zweitveröffentlichungen der Universität Potsdam : Humanwissenschaftliche Reihe - 339 KW - plantar fascia KW - reliability KW - sonography KW - musculoskeletal Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-400615 ER - TY - GEN A1 - Carlsohn, Anja A1 - Cassel, Michael A1 - Linné, Karsten A1 - Mayer, Frank T1 - How much is too much? BT - a case report of nutritional supplement use of a high-performance athlete T2 - Postprints der Universität Potsdam : Humanwissenschaftliche Reihe N2 - Although dietary nutrient intake is often adequate, nutritional supplement use is common among elite athletes. However, high-dose supplements or the use of multiple supplements may exceed the recommended daily allowance (RDA) of particular nutrients or even result in a daily intake above tolerable upper limits (UL). The present case report presents nutritional intake data and supplement use of a highly trained male swimmer competing at international level. Habitual energy and micronutrient intake were analysed by 3 d dietary reports. Supplement use and dosage were assessed, and total amount of nutrient supply was calculated. Micronutrient intake was evaluated based on RDA and UL as presented by the European Scientific Committee on Food, and maximum permitted levels in supplements (MPL) are given. The athlete’s diet provided adequate micronutrient content well above RDA except for vitamin D. Simultaneous use of ten different supplements was reported, resulting in excess intake above tolerable UL for folate, vitamin E and Zn. Additionally, daily supplement dosage was considerably above MPL for nine micronutrients consumed as artificial products. Risks and possible side effects of exceeding UL by the athlete are discussed. Athletes with high energy intake may be at risk of exceeding UL of particular nutrients if multiple supplements are added. Therefore, dietary counselling of athletes should include assessment of habitual diet and nutritional supplement intake. Educating athletes to balance their diets instead of taking supplements might be prudent to prevent health risks that may occur with long-term excess nutrient intake. T3 - Zweitveröffentlichungen der Universität Potsdam : Humanwissenschaftliche Reihe - 515 KW - dietary supplements KW - tolerable upper limits KW - elite athletes KW - vitamins KW - minerals Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-412910 SN - 1866-8364 IS - 515 ER - TY - GEN A1 - Carlsohn, Anja A1 - Scharhag-Rosenberger, Friederike A1 - Cassel, Michael A1 - Mayer, Frank T1 - Resting Metabolic Rate in Elite Rowers and Canoeists: Difference between Indirect Calorimetry and Prediction N2 - Background: Athletes may differ in their resting metabolic rate (RMR) from the general population. However, to estimate the RMR in athletes, prediction equations that have not been validated in athletes are often used. The purpose of this study was therefore to verify the applicability of commonly used RMR predictions for use in athletes. Methods: The RMR was measured by indirect calorimetry in 17 highly trained rowers and canoeists of the German national teams (BMI 24 ± 2 kg/m2, fat-free mass 69 ± 15 kg). In addition, the RMR was predicted using Cunningham (CUN) and Harris-Benedict (HB) equations. A two-way repeated measures ANOVA was calculated to test for differences between predicted and measured RMR (α = 0.05). The root mean square percentage error (RMSPE) was calculated and the Bland-Altman procedure was used to quantify the bias for each prediction. Results: Prediction equations significantly underestimated the RMR in males (p < 0.001). The RMSPE was calculated to be 18.4% (CUN) and 20.9% (HB) in the entire group. The bias was 133 kcal/24 h for CUN and 202 kcal/24 h for HB. Conclusions: Predictions significantly underestimate the RMR in male heavyweight endurance athletes but not in females. In athletes with a high fat-free mass, prediction equations might therefore not be applicable to estimate energy requirements. Instead, measurement of the resting energy expenditure or specific prediction equations might be needed for the individual heavyweight athlete. T3 - Zweitveröffentlichungen der Universität Potsdam : Humanwissenschaftliche Reihe - 329 KW - Energy requirement KW - Calorimetry KW - Fat-free mass KW - Nutritional counseling KW - Athletes Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-399837 ER - TY - JOUR A1 - Risch, Lucie A1 - Stoll, Josefine A1 - Schomöller, Anne A1 - Engel, Tilman A1 - Mayer, Frank A1 - Cassel, Michael T1 - Intraindividual Doppler Flow Response to Exercise Differs Between Symptomatic and Asymptomatic Achilles Tendons JF - Frontiers in physiology N2 - Objective: This study investigated intraindividual differences of intratendinous blood flow (IBF) in response to running exercise in participants with Achilles tendinopathy. Design: This is a cross-sectional study. Setting: The study was conducted at the University Outpatient Clinic. Participants: Sonographic detectable intratendinous blood flow was examined in symptomatic and contralateral asymptomatic Achilles tendons of 19 participants (42 ± 13 years, 178 ± 10 cm, 76 ± 12 kg, VISA-A 75 ± 16) with clinically diagnosed unilateral Achilles tendinopathy and sonographic evident tendinosis. Intervention: IBF was assessed using Doppler ultrasound “Advanced Dynamic Flow” before (Upre) and 5, 30, 60, and 120 min (U5–U120) after a standardized submaximal constant load run. Main Outcome Measure: IBF was quantified by counting the number (n) of vessels in each tendon. Results: At Upre, IBF was higher in symptomatic compared with asymptomatic tendons [mean 6.3 (95% CI: 2.8–9.9) and 1.7 (0.4–2.9), p < 0.01]. Overall, 63% of symptomatic and 47% of asymptomatic Achilles tendons responded to exercise, whereas 16 and 11% showed persisting IBF and 21 and 42% remained avascular throughout the investigation. At U5, IBF increased in both symptomatic and asymptomatic tendons [difference to baseline: 2.4 (0.3–4.5) and 0.9 (0.5–1.4), p = 0.05]. At U30 to U120, IBF was still increased in symptomatic but not in asymptomatic tendons [mean difference to baseline: 1.9 (0.8–2.9) and 0.1 (-0.9 to 1.2), p < 0.01]. Conclusion: Irrespective of pathology, 47–63% of Achilles tendons responded to exercise with an immediate acute physiological IBF increase by an average of one to two vessels (“responders”). A higher amount of baseline IBF (approximately five vessels) and a prolonged exercise-induced IBF response found in symptomatic ATs indicate a pain-associated altered intratendinous “neovascularization.” KW - achilles tendinopathy KW - tendinosis KW - neovascularization KW - ultrasound KW - advanced dynamic flow KW - sonography Y1 - 2021 U6 - https://doi.org/10.3389/fphys.2021.617497 SN - 1664-042X VL - 12 SP - 1 EP - 8 PB - Frontiers Research Foundation CY - Lausanne, Schweiz ER - TY - GEN A1 - Risch, Lucie A1 - Stoll, Josefine A1 - Schomöller, Anne A1 - Engel, Tilman A1 - Mayer, Frank A1 - Cassel, Michael T1 - Intraindividual Doppler Flow Response to Exercise Differs Between Symptomatic and Asymptomatic Achilles Tendons T2 - Zweitveröffentlichungen der Universität Potsdam : Humanwissenschaftliche Reihe N2 - Objective: This study investigated intraindividual differences of intratendinous blood flow (IBF) in response to running exercise in participants with Achilles tendinopathy. Design: This is a cross-sectional study. Setting: The study was conducted at the University Outpatient Clinic. Participants: Sonographic detectable intratendinous blood flow was examined in symptomatic and contralateral asymptomatic Achilles tendons of 19 participants (42 ± 13 years, 178 ± 10 cm, 76 ± 12 kg, VISA-A 75 ± 16) with clinically diagnosed unilateral Achilles tendinopathy and sonographic evident tendinosis. Intervention: IBF was assessed using Doppler ultrasound “Advanced Dynamic Flow” before (Upre) and 5, 30, 60, and 120 min (U5–U120) after a standardized submaximal constant load run. Main Outcome Measure: IBF was quantified by counting the number (n) of vessels in each tendon. Results: At Upre, IBF was higher in symptomatic compared with asymptomatic tendons [mean 6.3 (95% CI: 2.8–9.9) and 1.7 (0.4–2.9), p < 0.01]. Overall, 63% of symptomatic and 47% of asymptomatic Achilles tendons responded to exercise, whereas 16 and 11% showed persisting IBF and 21 and 42% remained avascular throughout the investigation. At U5, IBF increased in both symptomatic and asymptomatic tendons [difference to baseline: 2.4 (0.3–4.5) and 0.9 (0.5–1.4), p = 0.05]. At U30 to U120, IBF was still increased in symptomatic but not in asymptomatic tendons [mean difference to baseline: 1.9 (0.8–2.9) and 0.1 (-0.9 to 1.2), p < 0.01]. Conclusion: Irrespective of pathology, 47–63% of Achilles tendons responded to exercise with an immediate acute physiological IBF increase by an average of one to two vessels (“responders”). A higher amount of baseline IBF (approximately five vessels) and a prolonged exercise-induced IBF response found in symptomatic ATs indicate a pain-associated altered intratendinous “neovascularization.” T3 - Zweitveröffentlichungen der Universität Potsdam : Humanwissenschaftliche Reihe - 746 KW - achilles tendinopathy KW - tendinosis KW - neovascularization KW - ultrasound KW - advanced dynamic flow KW - sonography Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-542865 SN - 1866-8364 SP - 1 EP - 8 PB - Universitätsverlag Potsdam CY - Potsdam ER - TY - GEN A1 - Wojcinski, Sebastian A1 - Dupont, Jennifer A1 - Schmidt, Werner A1 - Cassel, Michael A1 - Hillemanns, Peter T1 - Real-time ultrasound elastography in 180 axillary lymph nodes BT - elasticity distribution in healthy lymph nodes and prediction of breast cancer metastases T2 - Postprints der Universität Potsdam : Humanwissenschaftliche Reihe N2 - Background To determine the general appearance of normal axillary lymph nodes (LNs) in real-time tissue sonoelastography and to explore the method′s potential value in the prediction of LN metastases. Methods Axillary LNs in healthy probands (n=165) and metastatic LNs in breast cancer patients (n=15) were examined with palpation, B-mode ultrasound, Doppler and sonoelastography (assessment of the elasticity of the cortex and the medulla). The elasticity distributions were compared and sensitivity (SE) and specificity (SP) were calculated. In an exploratory analysis, positive and negative predictive values (PPV, NPV) were calculated based upon the estimated prevalence of LN metastases in different risk groups. Results In the elastogram, the LN cortex was significantly harder than the medulla in both healthy (p=0.004) and metastatic LNs (p=0.005). Comparing healthy and metastatic LNs, there was no difference in the elasticity distribution of the medulla (p=0.281), but we found a significantly harder cortex in metastatic LNs (p=0.006). The SE of clinical examination, B-mode ultrasound, Doppler ultrasound and sonoelastography was revealed to be 13.3%, 40.0%, 14.3% and 60.0%, respectively, and SP was 88.4%, 96.8%, 95.6% and 79.6%, respectively. The highest SE was achieved by the disjunctive combination of B-mode and elastographic features (cortex >3mm in B-mode or blue cortex in the elastogram, SE=73.3%). The highest SP was achieved by the conjunctive combination of B-mode ultrasound and elastography (cortex >3mm in B-mode and blue cortex in the elastogram, SP=99.3%). Conclusions Sonoelastography is a feasible method to visualize the elasticity distribution of LNs. Moreover, sonoelastography is capable of detecting elasticity differences between the cortex and medulla, and between metastatic and healthy LNs. Therefore, sonoelastography yields additional information about axillary LN status and can improve the PPV, although this method is still experimental. T3 - Zweitveröffentlichungen der Universität Potsdam : Humanwissenschaftliche Reihe - 626 KW - breast ultrasound KW - axillary lymph nodes KW - sonoelastography KW - real-time tissue elastography KW - cancer detection KW - elasticity imaging KW - HI-RTE KW - lymph node metastases Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-431584 SN - 1866-8364 IS - 626 ER -