TY - THES A1 - Stanke, Sandra T1 - AC electrokinetic immobilization of influenza viruses and antibodies on nanoelectrode arrays for on-chip immunoassays T1 - AC elektrokinetische Immobilisierung von Influenzaviren und Antikörpern auf Nanoelektrodenarrays für on-Chip Immunoassays N2 - In the present thesis, AC electrokinetic forces, like dielectrophoresis and AC electroosmosis, were demonstrated as a simple and fast method to functionalize the surface of nanoelectrodes with submicrometer sized biological objects. These nanoelectrodes have a cylindrical shape with a diameter of 500 nm arranged in an array of 6256 electrodes. Due to its medical relevance influenza virus as well as anti-influenza antibodies were chosen as a model organism. Common methods to bring antibodies or proteins to biosensor surfaces are complex and time-consuming. In the present work, it was demonstrated that by applying AC electric fields influenza viruses and antibodies can be immobilized onto the nanoelectrodes within seconds without any prior chemical modification of neither the surface nor the immobilized biological object. The distribution of these immobilized objects is not uniform over the entire array, it exhibits a decreasing gradient from the outer row to the inner ones. Different causes for this gradient have been discussed, such as the vortex-shaped fluid motion above the nanoelectrodes generated by, among others, electrothermal fluid flow. It was demonstrated that parts of the accumulated material are permanently immobilized to the electrodes. This is a unique characteristic of the presented system since in the literature the AC electrokinetic immobilization is almost entirely presented as a method just for temporary immobilization. The spatial distribution of the immobilized viral material or the anti-influenza antibodies at the electrodes was observed by either the combination of fluorescence microscopy and deconvolution or by super-resolution microscopy (STED). On-chip immunoassays were performed to examine the suitability of the functionalized electrodes as a potential affinity-based biosensor. Two approaches were pursued: A) the influenza virus as the bio-receptor or B) the influenza virus as the analyte. Different sources of error were eliminated by ELISA and passivation experiments. Hence, the activity of the immobilized object was inspected by incubation with the analyte. This resulted in the successful detection of anti-influenza antibodies by the immobilized viral material. On the other hand, a detection of influenza virus particles by the immobilized anti-influenza antibodies was not possible. The latter might be due to lost activity or wrong orientation of the antibodies. Thus, further examinations on the activity of by AC electric fields immobilized antibodies should follow. When combined with microfluidics and an electrical read-out system, the functionalized chips possess the potential to serve as a rapid, portable, and cost-effective point-of-care (POC) device. This device can be utilized as a basis for diverse applications in diagnosing and treating influenza, as well as various other pathogens. N2 - In der vorliegenden Arbeit wurden AC elektrokinetische Kräfte, wie die Dielektrophorese und die AC Elektroosmose, als einfache und schnelle Methode zur Funktionalisierung der Oberfläche von Nanoelektroden mit biologischen Objekten in Submikrometergröße demonstriert. Diese Nanoelektroden haben eine zylindrische Form mit einem Durchmesser von 500 nm und sind in einem Array aus 6256 Elektroden angeordnet. Aufgrund ihrer medizinischen Relevanz wurden Influenzaviren sowie anti-Influenza Antikörper als Modellorganismus ausgewählt. Gängige Methoden, um Antikörper oder Proteine auf Biosensoroberflächen zu bringen, sind komplex und zeitaufwändig. In der vorliegenden Arbeit wurde gezeigt, dass durch die Anwendung elektrischer Wechselfelder Influenzaviren und Antikörper innerhalb von Sekunden auf den Nanoelektroden immobilisiert werden können, ohne dass zuvor eine chemische Modifikation der Oberfläche noch des immobilisierten biologischen Objekts erforderlich ist. Die Verteilung dieser immobilisierten Objekte ist über das gesamte Array ungleichmäßig. Es kommt zur Ausbildung eines Gradienten, welcher von der äußeren zur den inneren Reihen hin abnimmt. Verschiedene Ursachen für diesen Gradienten wurden diskutiert, beispielsweise der Vortex-förmige Flüssigkeitsstrom über den Nanoelektroden, der unter anderem durch elektrothermische Flüssigkeitsbewegung erzeugt wird. Es wurde gezeigt, dass Teile des akkumulierten Materials dauerhaft an den Elektroden immobilisiert sind. Dies ist ein Alleinstellungsmerkmal des vorgestellten Systems, da in der Literatur die AC elektrokinetische Immobilisierung fast ausschließlich als Methode nur zur temporären Immobilisierung dargestellt wird. Die räumliche Verteilung des immobilisierten Virusmaterials bzw. der anti-Influenza Antikörper an den Elektroden wurde entweder durch die Kombination aus Fluoreszenzmikroskopie und Dekonvolution oder durch super-resolution Mikroskopie (STED) betrachtet. Es wurden On-Chip-Immunoassays durchgeführt, um die Eignung der funktionalisierten Elektroden für einen potenziellen affinitätsbasierten Biosensor zu untersuchen. Dabei wurden zwei Ansätze verfolgt: A) Influenzaviren als Biorezeptor oder B) Influenzavirus als Analyt. Verschiedene Fehlerquellen wurden mittels ELISA und Passivierungsexperimente eliminiert. Infolgedessen wurde die Aktivität der immobilisierten Objekte durch Inkubation mit dem Analyten überprüft. Dies führte zum erfolgreichen Nachweis von anti-Influenza Antikörpern mittels immobilisiertem Virusmaterial. Andererseits war ein Nachweis von Influenzaviruspartikeln durch die immobilisierten anti-Influenza Antikörper nicht möglich. Letzteres könnte auf einen Aktivitätsverlust oder eine falsche Ausrichtung der Antikörper zurückzuführen sein. Daher sollten weitere Untersuchungen zur Aktivität von durch elektrische Wechselfelder immobilisierte Antikörper folgen. In Kombination mit Mikrofluidik und einem elektrischen Auslesesystem besitzen die funktionalisierten Chips das Potenzial, als schnelle, tragbare und kostengünstige Point-of-Care-Einheit (POC) zu dienen. Dieses Einheit kann als Grundlage für vielfältige Anwendungen bei der Diagnose und Behandlung von Influenza und verschiedenen anderen Krankheitserregern genutzt werden. KW - AC electrokinetics KW - AC Elektrokinetik KW - AC electroosmosis KW - AC Elektroosmosis KW - dielectrophoresis KW - Dielektrophorese KW - virus KW - Virus KW - influenza KW - Influenza KW - antibody KW - Antikörper KW - nanoelectrodes KW - Nanoelektroden KW - lab-on-chip KW - lab-on-chip KW - LOC KW - LOC KW - point-of-care KW - point-of-care KW - POC KW - POC KW - immunoassay KW - Immunoassay Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-617165 ER - TY - THES A1 - Göthel, Markus T1 - Entwicklung eines Verfahrens zur Generierung von spezifischen monoklonalen Antikörpern gegen Mikroorganismen basierend auf in silico Epitopanalysen T1 - A new workflow to generate monoclonal antibodies against microorganisms based on in silico epitope predictions N2 - Monoklonale Antikörper (mAK) sind eines der wichtigsten Biomoleküle für die Umweltanalytik und die medizinische Diagnostik. Für die Detektion von Mikroorganismen bilden sie die Grundlage für ein schnelles und präzises Testverfahren. Bis heute gibt es, aufgrund des hohen zeitlichen und materiellen Aufwandes und der unspezifischen Immunisierungsstrategien, nur wenige mAK, die spezifisch Mikroorganismen erkennen. Zu diesem Zweck sollte ein anwendbares Verfahren für die Generierung von mAK gegen Mikroorganismen entwickelt werden, welches anhand von Escherichia coli O157:H7 und Legionella pneumophila validiert wurde. In dieser Dissertation konnten neue Oberflächenstrukturen auf den Mikroorganismen mittels vergleichender Genomanalysen und in silico Epitopanalysen identifiziert werden. Diese wurden in das Virushüllprotein VP1 integriert und für eine gezielte Immunisierungsstrategie verwendet. Für die Bestimmung antigenspezifischer antikörperproduzierender Hybridome wurde ein Immunfärbeprotokoll entwickelt und etabliert, um die Hybridome im Durchflusszytometer zu sortieren. In der vorliegenden Studie konnten für E. coli O157:H7 insgesamt 53 potenzielle Proteinkandidaten und für L. pneumophila 38 Proteine mithilfe der bioinformatischen Analyse identifiziert werden. Fünf verschiedene potenzielle Epitope wurden für E. coli O157:H7 und drei verschiedenen für L. pneumophila ausgewählt und für die Immunisierung mit chimären VP1 verwendet. Alle Immunseren zeigten eine antigenspezifische Immunantwort. Aus den nachfolgend generierten Hybridomzellen konnten mehrere Antikörperkandidaten gewonnen werden, welche in Charakterisierungsstudien eine starke Bindung zu E. coli O157:H7 bzw. L. pneumophila vorwiesen. Kreuzreaktivitäten zu anderen relevanten Mikroorganismen konnten keine bzw. nur in geringem Maße festgestellt werden. Folglich konnte der hier beschriebene interdisziplinäre Ansatz zur Generierung spezifischer mAK gegen Mikroorganismen nachweislich spezifische mAK hervorbringen und ist als hocheffizienter Arbeitsablauf für die Herstellung von Antikörpern gegen Mikroorganismen einsetzbar. N2 - Monoclonal antibodies (mAbs) are one of the most important biomolecules for environmental analysis and medical diagnostics. For the detection of microorganisms, they form the basis for a rapid and precise test procedure. Until today, due to the substantial time and material effort and the non-specific immunization strategies, there are only a few mAbs that specifically detect microorganisms. Therefore, an easy-to-use methodology for the generation of mAbs against microorganisms was developed and validated using Legionella pneumophila and Escherichia coli O157:H7. In this dissertation, several new surface structures on the microorganisms were identified using comparative genomic analyses and in silico epitope modeling. These were integrated into the VP1 viral envelope protein and used for a specific immunization strategy. For the identification of antigen-specific antibody-producing hybridomas, an immunostaining protocol was developed and established to sort the hybridomas. In the present study, 53 potential protein candidates were identified for E. coli O157:H7 and 38 proteins for L. pneumophila using bioinformatic analysis methods. Five different peptide epitopes were selected for E. coli O157:H7 and three different peptide epitopes for L. pneumophila for immunization using chimeric VP1. All immune sera showed an antigen-specific immune response. Several antibody candidates were obtained from the generated hybridoma cells, which showed strong binding to E. coli O157:H7 and L. pneumophila. Cross-reactivity to other relevant microorganisms could not be detected or could only be observed to a minor extent. Consequently, the interdisciplinary approach to generate specific mAbs against microorganisms has been shown to generate specific mAbs and is applicable as a highly efficient workflow for the generation of antibodies against microorganisms. KW - Antikörper KW - antibody KW - Epitopvorhersage KW - epitop prediction KW - Escherichia coli KW - legionella pneumophila Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-588017 ER - TY - THES A1 - Ramm, Timo T1 - Entwicklung von Multiplex-Methoden zur Antikörper-Charakterisierung und Validierung N2 - Antikörper werden in verschiedensten Bereichen, sowohl zu therapeutischen als auch zu diagnostischen und forschungsorientierten Zwecken verwendet. Vor der Verwendung des Antikörpers bedarf es der Charakterisierung seiner Eigenschaften, in Bezug auf sein Epitop und sein Bindeverhalten gegenüber dem Paratop. Gleichzeitig muss, in Abhängigkeit des Einsatzes, der Antikörper, für den gewünschten Gebrauch, validiert werden. Zu diesem Zweck wurden in der vorliegenden Arbeit Bead-basierte, multiplexe Testsysteme entworfen, ausgetestet und etabliert mit dem Ziel, eine einfache Screeningmethode zu entwickeln, um eine hohe Anzahl an Proben beziehungsweise Analyten gleichzeitig bestimmen zu können. Dafür wurden drei verschiedene Herangehensweisen etabliert. So wurden ein phospho-PKA-Substrat Antikörper, welcher phosphorylierte Bindemotive der PKA der Form RRxpS erkennt, gleichzeitig mit einer Reihe an Peptide getestet, welche Punktmutationen im Vergleich zur Konsensussequenz enthielten, um den Einfluss einzelner Aminosäuren auf die Bindung des Antikörpers zu untersuchen. Es konnte im Multiplex gezeigt werden, dass die Unterschiede im Antikörperbindungsverhalten in Abhängigkeit der Aminosäure an verschiedenen P-Positionen detektierbar waren. Mit dem Bead-basierten Multiplexansatz konnten, durch Messungen von Konzentrationsreihen des Antikörpers, Bindungskinetiken aufgenommen und diese mit bereits etablierten Methoden verglichen werden. Des Weiteren wurden verschiedene Antikörper, welche essenzielle Bestandteile von Bead-basierten Testsystemen darstellten, validiert. Es wurden dabei verschiedene Antikörper, welche spezifisch THC und CBD erkennen ausgetestet und anschließend ein kompetitiver Assay zur Detektion von THC und CBD in humanem Serum etabliert, und die Nachweisgrenzen bestimmt. Ferner sollten Pferdeseren von Tieren, welche am Sommerekzem leiden, auf ihren IgE-Gehalt hin bestimmt werden. Dafür wurden relevante Proteine rekombinant hergestellt und durch Immobilisierung an Beads im Multiplex mit Serum inkubiert. Die spezifische Bindung des IgE an die Allergen sollte damit messbar gemacht werden können. Für die Gesamtvalidierung des Testsystems wurden zuvor sämtliche Einzelschritte einzeln validiert, um im Anschluss im multiplexen Screening zu vermessen. Die Nutzung von Bead-basierten Multiplexmessungen als eine Plattformtechnologie erleichtert die Charakterisierung von Antikörpern sowie ihre Validierung für verschiedene Testsysteme. N2 - Antibodies are widely used in different fields, which include therapeutic as well as diagnostic and research applications Before the antibody can be used, its properties must be characterized with regard to its epitope and its binding behavior to the paratope. At the same time, depending on the application, the antibody must be validated for its desired use. For this purpose, bead-based multiplex assay systems were designed, tested, and established with the aim of developing a simple screening method to simultaneously measure a high number of samples or analytes. Thus, a phospho-PKA-substrate antibody, which recognizes phosphorylated binding motifs of PKA with the RRxpS motif, was tested. A series of peptides containing point mutations as compared to consensus sequences were used to investigate the influence of individual amino acids on the binding of the antibody. In a multiplex approach it was shown that the differences in the antibody binding behavior were detectable at different P-positions depending on the amino acid. Furthermore, it was possible to measure binding kinetics by the bead-based multiplex approach using dilution series of the antibody, and to compare these with already established methods. In addition to that, different antibodies, which were applied as essential components of bead-based biosensor systems, were validated. On the one hand, different antibodies specifically recognizing THC and CBD were tested and subsequently a competitive assay for the detection of THC and CBD in human serum was established. The detection limits could be determined. On the other hand, the IgG level in horse sera from animals suffering from sweet itch were determined. For this purpose, relevant proteins were recombinantly expressed, immobilized on beads and incubated with serum in a multiplex approach. The specific binding of IgE to the allergen was measurable. For the overall validation of the test system, all individual steps were partially validated beforehand to allow for a measurement in the multiplex screening system. Thus, using the advantages of bead-based multiplex measurements, a platform for the characterization of antibodies as well as their validation in different test systems was demonstrated. KW - Antikörper KW - Multiplex KW - THC KW - Proteinkinase A KW - Sommerekzem KW - CBD KW - Bead KW - Antikörpercharakterisierung KW - Antikörpervalidierung KW - antibody KW - antibody characterization KW - antibody validation KW - THC KW - CBD KW - Proteinkinase A KW - summer eczema Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-561531 ER - TY - THES A1 - Michelchen, Sophia T1 - Etablierung einer Antigen-spezifischen Aktivierung von B-Lymphozyten in vitro N2 - Monoklonale Antikörper sind essenzielle Werkzeuge in der modernen Laboranalytik sowie in der medizinischen Therapie und Diagnostik. Die Herstellung monoklonaler Antikörper ist ein zeit- und arbeitsintensiver Prozess. Herkömmliche Methoden beruhen auf der Immunisierung von Labortieren, die mitunter mehrere Monate in Anspruch nimmt. Anschließend werden die Antikörper-produzierenden B-Lymphozyten bzw. deren Antikörpergene isoliert und in Screening-Verfahren untersucht, um geeignete Binder zu identifizieren. Der Transfer der humoralen Immunantwort in eine in vitro Umgebung erlaubt eine Verkürzung des Prozesses und umgeht die Notwendigkeit der in vivo Immunisierung. Das komplexe Zusammenspiel aller involvierten Immunzellen in vitro abzubilden, stellt sich allerdings als schwierig dar. Der Schwerpunkt dieser Arbeit war deshalb die Realisierung einer vereinfachten In vitro Immunisierung, die sich auf die Protagonisten der Antikörper-Produktion konzentriert: die B-Lymphozyten. Darüber hinaus sollte eine permanente Zelllinie etabliert werden, die zur Antikörper-Herstellung eingesetzt werden und die Verwendung von Primärzellen ersetzen würde. Im ersten Teil der Arbeit wurde ein Protokoll zur In vitro Immunisierung muriner BLymphozyten etabliert. In Vorversuchen wurden die optimalen Konditionen für die Antigenspezifische Aktivierung gereinigter Milz-B-Lymphozyten aus nicht-immunisierten Mäusen determiniert. Dazu wurde der Einfluss verschiedener Stimuli auf die Produktion unspezifischer und spezifischer Antikörper untersucht. Eine Kombination aus dem Modellantigen VP1 (Hamster Polyomavirus Hüllprotein 1), einem Anti-CD40-Antikörper, Interleukin 4 (IL 4) und Lipopolysaccharid (LPS) oder IL 7 induzierte nachweislich eine Antigen-spezifische Antikörper-Antwort in vitro. Als Indikatoren einer erfolgreichen Aktivierung der B-Lymphozyten infolge der in vitro Stimulation wurden die rapide Proliferation und die Expression charakteristischer Aktivierungsmarker auf der Zelloberfläche nachgewiesen. In einer Zeitreihe über zehn Tage wurde am zehnten Tag der In vitro Immunisierung die verhältnismäßig höchste Konzentration Antigen-spezifischer IgG-Antikörper im Kulturüberstand der stimulierten Zellen nachgewiesen. Als nächster Schritt sollte eine permanente Zelllinie hergestellt werden, die statt primärer BLymphozyten für die zuvor etablierte In vitro Immunisierung eingesetzt werden könnte. Zu diesem Zweck wurden retrovirale Vektoren hergestellt, die durch den Transfer verschiedener Onkogene in murine B-Lymphozyten bzw. deren Vorläuferzellen das Proliferationsverhalten der Zellen manipulieren sollen. Es wurden Retroviren mit Doxycyclin-induzierbaren Expressionskassetten mit den Onkogenen cmyc, Bcl2, BclxL und dem Fusionsgen NUP98HOXB4 generiert. Eine Testzelllinie wurde erfolgreich mit den hergestellten Retroviren transduziert und die Funktionalität der hergestellten Viren anhand verschiedener Assays belegt. Die transferierten Gene konnten in der Testzelllinie auf DNAEbene nachgewiesen oder die Überexpression der entsprechenden Proteine im Western Blot detektiert werden. Es wurden schließlich B-Lymphozyten bzw. unreife Vorläuferzellen derselben mit den generierten Retroviren transduziert und mit Knochenmark-ähnlichen Stromazellen co-kultiviert. Aus keinem der transduzierten Ansätze konnte bisher eine Zelllinie oder eine Langzeit-Kultur etabliert werden. Im letzten Teil der Arbeit wurde die Effektivität und Übertragbarkeit des zuvor etablierten Protokolls zur In vitro Immunisierung muriner B-Lymphozyten anhand verschiedener Antigene gezeigt. Es konnten in vitro spezifische IgG-Antworten gegen VP1, Legionella pneumophila und das Protein Mip, von dem ein Peptid in das zur Immunisierung eingesetzte VP1 integriert wurde, induziert werden. Die stimulierten B-Lymphozyten wurden durch Fusion mit Myelomzellen in permanente Antikörper-produzierende Zelllinien transformiert. Dabei konnten mehrere Hybridomzelllinien generiert werden, die spezifische IgGAntikörper gegen VP1 oder Mip produzieren. Die generierten Antikörper konnten sowohl im Western Blot als auch im ELISA (Enzyme-Linked Immunosorbent Assay) das entsprechende Antigen spezifisch binden. Die hier etablierte In vitro Immunisierung bietet eine effektive Alternative zu bisherigen Verfahren zur Herstellung spezifischer Antikörper. Sie ersetzt die Immunisierung von Versuchstieren und reduziert den Zeitaufwand erheblich. In Kombination mit der Hybridomtechnologie können die in vitro immunisierten Zellen, wie hier demonstriert, zur Generation von Hybridomzelllinien und zur Herstellung monoklonaler Antikörper genutzt werden. Um die Verwendung von Versuchstieren in dieser Methode durch eine adäquate permanente Zelllinie zu ersetzen, muss die genetische Veränderung von B-Lymphozyten und unreifen hämatopoetischen Zellen optimiert werden. Die Ergebnisse bieten eine Basis für eine universelle, Spezies-unabhängige Methodik zur Antikörperherstellung und für die Etablierung einer idealen, tierfreien In vitro Immunisierung. N2 - Monoclonal antibodies are essential tools in modern analytics as well as medical therapy and diagnostics. The production of such is a time consuming and labor intensive process. Common methods rely on the immunization of laboratory animals which comprises up to several months. Subsequently antibody producing B lymphocytes or their antibody coding genes are isolated and screened for suitable binders. The transfer of the humoral immune reaction into an in vitro setting allows to shorten this process and circumvents the necessity of in vivo immunization. The imitation of the complex interaction between all involved immune cells however is difficult to mimic in vitro. Consequently, the main focus of this thesis was the establishment of a simplified in vitro immunization focusing only on the protagonists of antibody production: B lymphocytes. Furthermore a permanent cell line should be generated for the implementation in antibody production and to replace the use of primary cells. In the first part of this work a protocol for the in vitro immunization of murine B lymphocytes was established. In preliminary experiments the optimal conditions for the antigen specific activation of spleen B lymphocytes isolated from non-immunized mice were determined. Therefore the influence of various stimuli on the production of unspecific and specific antibodies was investigated. A combination of the model antigen VP1 (Hamster Polyomavirus capsid protein 1), an anti-CD40 antibody, interleukin 4 (IL 4) and lipopolysaccharide (LPS) or IL 7 evidently induced an antigen specific antibody response in vitro. To proof successful B lymphocyte activation following the in vitro stimulation rapid cell proliferation and the expression of characteristic activation markers on cell surfaces were shown. Over the course of ten days of in vitro immunization the production of antigen specific IgG antibodies in the supernatant of stimulated B lymphocytes was monitored peaking on day ten. Next a permanent cell line was to be established for replacing primary B lymphocytes in the previously established in vitro immunization. For this purpose several retroviral vectors were generated to manipulate the proliferative behavior of B lymphocytes or their progenitor cells by transferring different oncogenes into those cells. Retroviruses with doxycycline inducible expression cassettes carrying the oncogenes cmyc, Bcl2, BclxL and the fusion gene NUP98HOXB4 were generated. A model cell line was successfully transduced with the generated retroviruses. The functionality of these viruses was shown in several assays. In the model cell line the transferred genes were shown to be part of their genome or the overexpression of the corresponding proteins was shown in Western Blots or fluorescent microscopy. Finally, B lymphocytes or respectively immature progenitor cells of such were transduced with the generated retroviruses and co-cultured with bone marrow-like stroma cells. Cells could be cultured for several weeks past their natural lifespan. However, none of the approaches led to the generation of a permanent cell line or the establishment of a long term culture system. In the final part of this thesis the effectivity and transferability of the previously established protocol for the in vitro immunization of murine B lymphocytes was shown by applying various antigens. Specific IgG responses were induced in vitro against VP1, Legionella pneumophila and the protein Mip, a peptide of which had been included in a VP1 carrier protein used for immunization. The stimulated B lymphocytes were fused with myeloma cells to produce permanent antibody secreting cell lines. Thereby several hybridoma cell lines were generated producing specific IgG antibodies against VP1 or Mip. The generated antibodies were purified and shown to specifically bind their antigen in ELISA and Western Blot. This protocol for in vitro immunization presented here poses an effective alternative to conventional methods for the production of specific antibodies. It replaces the immunization of laboratory animals and greatly reduces the time needed. As shown here, in combination with the hybridoma technology these in vitro immunized cells can be used for the generation of hybridoma cell lines and subsequently for the production of monoclonal antibodies. To replace the use of laboratory animals used in this method by a permanent cell line the genetic manipulation of B lymphocytes and immature hematopoietic cells needs to be optimized. The results provide a foundation for a universal, species-independent method for antibody production and for the establishment of an ideal, animal-free in vitro immunization. KW - B-Lymphozyten KW - Antikörper KW - Antibodies KW - B lymphocytes KW - in vitro immunization KW - In vitro-Immunisierung Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-530272 ER - TY - THES A1 - Teller, Carsten T1 - Entwicklung neuartiger biomimetischer Sensoren: ein bifunktionaler Sensor auf Basis haptenisierter Cholinesterase T1 - Development of novel biomimetic sensors: a bifunctional sensor based on haptenized cholinesterase N2 - In dieser Arbeit wird die Entwicklung eines bifunktionellen Biosensors nach dem Vorbild eines Baukastensystems beschrieben. Das Ziel wird durch die Kombination verschiedenster molekularer Erkennungselemente erreicht. Solche molekularen Erkennungselemente im verwendeten System sind: • Propidium und die periphere anionische Bindungsstelle der Acetylcholinesterase (AChE) • Organophosphate und das aktive Zentrum der AChE • ein an die AChE gekoppeltes Hapten und das Epitop eines Antikörpers • ein an die AChE gekoppeltes Hapten, das als Ligand ein weiteres Enzym bindet Neben dem molekularen Erkennungselement wird ein Biosensor ebenso durch die Art des Transducers charakterisiert. Hier werden Quarzplättchen mit Goldelektroden zur Signalumwandlung eingesetzt. Die Verwendung solcher Sensoren mit einem EQCM-Gerät (electrochemical quartz crystal microbalance) ermöglicht es zwei Messsignale gleichzeitig aufzunehmen: die piezoelektrische Bestimmung einer Massebeladung und die amperometrische Detektion von Enzymaktivität auf der Sensoroberfläche. Für die Analytik stehen somit zwei verschiedene Assay-Varianten zur Verfügung: die Bestimmung der Inhibition der ACHE-Aktivität und ein Bindungstest über das Hapten. Die Basis beider Tests ist die Modifizierung der piezoelektrischen Kristalle mit Propidium – einem reversiblen Inhibitor der Acetylcholinesterase. Dies ermöglicht die Beladung des Sensors mit AChE über die Wechselwirkung mit der peripheren anionischen Bindungsstelle des Enzyms. Die Aktivität der so immobilisierten AChE und die Inhibition durch Organophosphate (Pestizide) werden amperometrisch bestimmt. Durch die chemische Kopplung eines Hapten an die Cholinesterase wird ein weiteres Erkennungselement eingeführt. Das eröffnet die Möglichkeit, an die auf dem Propidium-modifizierten Sensor immobilisierte, haptenisierte Cholinesterase einen Antikörper zu binden. Als Voraussetzung für elektrochemische Bestimmung der AChE-Aktivität wurde zunächst die Optimierung der amperometrischen Messmethode vorgenommen. Die Oxidatationspotentiale für die Detektion von Thiocholin wurden im Bereich von 150 mV bis 300 mV variiert. Dabei wurde für die nachfolgenden Untersuchungen eine Arbeitspotential von 200 mV (vs. Ag/AgCl) festgelegt, da hier das beste Verhältnis von gemessenem Oxidationsstrom und Langzeitstabilität der Propidium-modifizierten Sensoren erzielt wurde. Dieses Potential war deutlich geringer als die bisher publizierten Mediator-freien AChE-Biosensoren. Es wurde ein Vergleich verschiedener Organophosphate über ihre Inhibitionskonstanten durchgeführt, um diejenigen herauszufinden, die möglichst schnell mit dem aktiven Zentrum der Acetylcholinesterase reagieren. Das verwendete Messsystem beruht nicht auf der Vorinkubation der AChE und damit einer Einstellung des Inhibitionsgleichgewichts. Stattdessen wurde die Inhibition der AChE direkt im Fließsystem verfolgt. Daher war eine schnelle Inhibitionskinetik für einen empfindlichen Organophosphat-Nachweis erforderlich. Da einige Inhibitoren nur als Phosphothionat vorlagen, wurde die Überführung dieser Substanzen in die entsprechenden Oxo-Formen mittels N-Bromsuccinimid untersucht. Die NBS-Aktivierung wurde erfolgreich durchgeführt, die erwartete Inhibitionsstärke konnte jedoch aufgrund hydrolytischer Vorgänge nicht erreicht werden. Untersuchungen mit Diisopropylfluorophosphat (DFP) und Chlorpyriphos-oxon (CPO) konnten die Voruntersuchungen über die Inhibitionskinetik in Bezug auf die erreichten Nachweisgrenzen von 2E-06 M für DFP und 5E-08 M für CPO bestätigen. Für die chemische Modifizierung der Acetylcholinesterase wurde zunächst 2,4-Dichlorphenoxyessigsäure (2,4-D) als Hapten ausgewählt. 2,4-D wird als Herbizid eingesetzt und in der EU über die Gewässerschutzrichtlinie reguliert. 2,4-D konnte in unterschiedlichen molaren Verhältnissen von 2,6 : 1 bis 260 : 1 (2,4-D : AChE) nach Aktivierung mit einem Norbornendicarboximido-Derivat an die AChE gekoppelt werden. Dabei konnte die spezifische Aktivität der Acetylcholinesterase erhalten und die Bindung eines anti-2,4-D-Antikörpers ermöglicht werden. Zur Verstärkung des piezolelektrischen Signals der Antikörperbindung wurden die Immunoglobuline zunächst an Goldnanopartikel gekoppelt. Damit konnte eine Verstärkung um den Faktor 10 erreicht werden. Allerdings waren die Antikörper-modifizierten Goldnanopartikel nicht langzeitstabil. Daher wurden auch Silica-Nanopartikel als Matrix für die Antikörperkopplung getestet. Mit diesem System konnte eine Verstärkung um den Faktor von 5 bis 13 je nach Grad der Beladung den Nanopartikel mit Antikörper bestimmt werden. Die hohe unspezifische Bindung der Antikörper-Nanopartikel-Konjugate an den Propidium-modifizierten QCM-Sensor konnte keinen empfindlichen 2,4-D-Nachweis ermöglichen. Als Alternative wurde Kokain (Benzoylecgonin, BZE) als Hapten an die Aceytlcholinesterase gekoppelt. Da Kokain selbst auch als Inhibitor im aktiven Zentrum der AChE binden kann, wurden zwei verschiedene Strategien zur Konjugatsynthese verfolgt. Durch Zugabe von Kokain während der Kopplung sollte die kovalente Fixierung des Kokain-Derivats BZE-DADOO im aktiven Zentrum verhindert werden (Konjugat B). In der Tat konnten mit dieser Synthesestrategie 67% der spezifischen Cholinesterase-Aktivität erhalten werden, während im Kokain-freien Ansatz (Konjugat A) nur 2% der Ausgangsaktivität wiedergefunden wurden. Das BZE-AChE-Konjugat ermöglichte auch die Untersuchung der Bindungskinetik der anti-BZE-Antikörper. Dabei konnte eine Assoziationsgeschwindigkeitskonstante ka von 12911 l/(mol•s) berechnet werden. Dieser Wert ist trotz der vergleichsweise geringen Oberflächenbeladung vergleichbar mit den in der Literatur angegebenen Werten. Die Dissoziationsgeschwindigkeitskonstante ist mit 2,89E−3 1/s um den Faktor 30 höher als der Literaturwert. Diese Abweichung ist auf Unterschiede im Bindungsmodell zurückzuführen. Mit beiden BZE-AChE-Konjugaten konnte ein kompetetiver Immunoassay mit Kokain im Fließsystem durchgeführt werden. Dabei zeigte sich für beide Konjugate ein ähnlicher Testmittelpunkt: IC50 = 4,40E−8 mol/l für Konjugat A bzw. IC50 = 1,77E−8 mol/l für Konjugat B. Diese Werte sind vergleichbar zu bereits publizierten Kokainassays im Fließsystem. Wie vorstehend beschrieben, bindet Kokain als Inhibitor auch im aktiven Zentrum von Cholinesterasen. Diese Eigenschaft wurde genutzt, um ein zweites Enzym – Butyrylcholinesterase (BChE) – an die BZE-AChE zu binden. Die Spezifität dieser Bindung konnte durch die Abwesenheit einer Affinität der BChE zum Propidium und durch die Blockierbarkeit der Bindung von BChE und BZE-AChE durch Kokain nachgewiesen werden. Damit konnte erfolgreich die Kombination mehrere molekularer Erkennungselemente demonstriert werden. Die Propidium-Plattform ermöglicht den Aufbau einer Architektur aus verschiedenen Cholinesterasen, die über unterschiedliche Bindungsstellen wechselwirken. Sowohl freie als auch BZE-modifizierte AChE können über die Affinität zum Propidium auf dem EQCM-Sensor immobilisiert werden. Mit Kokain als Substrat der Butyrylcholinesterase kann Benzoylecgonin nicht nur als Epitop für die Bindung eines Antikörpers, sondern auch als Erkennungselement für die BChE genutzt werden. Auf der anderen Seite erschwert die geringe Affinität der BChE im Gegensatz zum anti-BZE-Antikörper den Einsatz dieses Systems für analytische Zwecke. Durch die Verwendung anderer Ligand-Enzym-Kombinationen läßt sich das in dieser Arbeit vorgestellte Konzept noch weiter ausbauen und ermöglicht damit eine Entwicklung ausgehend von „einfachen“ molekularen Erkennungselementen (MRE) hin zu „multifunktionellen“ Erkennungselementsystemen. In dieser Arbeit konnte demonstriert werden, dass der Aufbau solch komplexe Systeme möglich ist, ohne Abstriche in Bezug auf die Empfindlichkeit der einzelnen Assays hinzunehmen. N2 - This work describes the development of a bifunctional biosensor following a modular assembly approach. This aim is reached through the combination of various molecular recognition elements. The system presented herein uses the following recognition elements: • propidium and the peripheral anionic site of the acetylcholinesterase (AChE) • an organophosphate and the active site of the AChE • a hapten – covalently coupled to the AChE – and the epitope of an antibody • a hapten – covalently coupled to the AChE – binding as a ligand to another enzyme A biosensor is not only characterized by the molecular recognition element, but also by the type of signal transducer. This work is based on an electrochemical quartz crystal microbalance (EQCM) device that uses gold-plated quartz sensors for the signal transduction. This allows monitoring two distinct signals at the same time: the piezoelectric determination of a mass loading and the amperometrical detection of enzymatic activity on the sensor surface. Thus two different assay systems are provided: the determination of the inhibition of the AChE activity and ligand binding assay via the hapten. Both tests are based on the modification of the piezoelectric crystals with propidium – a reversible AChE inhibitor. This allows the deposition of AChE on the sensor surface via the interaction with the enzyme’s peripheral anionic site. The enzymatic activity of the in-situ immobilized AChE and the inhibition by organophosphates (pesticides) are measured amperometrically. Another recognition element is introduced by the chemical coupling of a hapten to the cholinesterase. This provides the opportunity bind an antibody to the haptenized cholinesterase that is immobilized on the propidium-modified sensor. Preliminary experiments were focussed on the improvement of the amperometric determination the AChE activity. The applied potential for the oxidation of thiocholine was changed over a range from 150 to 300 mV. The best results for the measured oxidation current and the long-term stability of the propidium-modified sensors were obtained at 200 mV (vs. Ag/AgCl). This potential was used throughout all subsequent experiments. This potential was also found to be lower as compared to mediator-free AChE-biosensors published hitherto. Different organophosphates were evaluated with regard to their inhibition constants to find those which react with active site of the acetylcholinesterase as fast as possible. The assay format used herein monitors the inhibition of the AChE directly in the flow-system. That is, it is not based preincubation of the enzyme with the inhibitor and therefore no inhibition equilibrium is reached. This approach requires fast inhibition kinetics in order to detect the organophosphates highly sensitively. Some of the inhibitors were only available in the phosphothionate form. Thus was necessary to convert these compounds to their respective oxon-forms by N-bromosuccinimide (NBS). The NBS-activation was performed successfully, though the expected inhibition potential could not be reached due to hydrolytic processes. Experiments with diisopropylfluorophosphate (DFP) und chlorpyriphos-oxon (CPO) could confirm the previous experiments on the inhibtion kinetics. Lower limits of detection of 2E-06 M for DFP and 5E-08 M for CPO could be reached with this approach. Initially 2,4-dichlorphenoxyacetic acid (2,4-D) was chosen as a hapten for the chemical modification of the acetylcholinesterase. The use of 2,4-D as a herbicide is regulated by the water protection directive of the European Union. 2,4-D was coupled to AChE in different molar ratios from 2,6 : 1 to 260 : 1 (2,4-D : AChE) after activation with a norbornendicarboximido derivative. The chosen coupling method allowed to recover the complete specific activity of the acetylcholinesterase and to bind a specific anti-2,4-D-antibody. Furthermore, the coupling of the immunoglobulins to gold nanoparticles was tested to enhance the piezoelectric signal of the antibody binding. An amplification factor of 10 was reached with this system. However the antibody-coated gold nanoparticles show a very poor long-term stability. Therefore also silica nanoparticles were tested as a matrix for the coupling of the antibodies. This approach yielded an amplification factor from 5 to 13 depending amount of antibodies bound to the nanoparticles. Unfortunately the high non-specific binding of the antibody nanoparticle conjugates did not allow a sensitive 2,4-D detection assay. Cocaine (benzoylecgonine, BZE) was coupled as a hapten to Acetylcholinesterase in an alternative approach. Two different strategies for the synthesis of the conjugate were pursued, since cocaine can bind also bind as an inhibitor for the AChE’s active site. The addition of excess cocaine during the coupling reaction should the covalent binding of the cocaine derivative BZE-DADOO at the active site (conjugate B). Indeed over two thirds of the original specific cholinesterase activity could be recovered with this strategy, while the cocaine-free batch (conjugate A) showed only 2% of the original activity. Furthermore the BZE-AChE conjugate allowed the evaluation of the binding kinetics of the anti-BZE-antibody. The association rate constant ka was calculated to 12911 l/(mol•s). Despite the low surface coverage this value is still comparable to other published results. The dissociation rate constant kd of 2,89E−3 1/s is thirty times higher than values found in the literature. This deviation is due to differences in the applied binding model. Both BZE-AChE conjugates could be applied in a competitive immunoassay for cocaine in the flow system. It was shown that for both conjugates a similar half maximal inhibitory concentration was reached: : IC50 = 4,40E−8 mol/l for conjugate A and IC50 = 1,77E−8 mol/l for conjugate B, respectively. These values are comparable to other published assay for cocaine in a flow system. As described earlier, cocaine is also able to bind to the active site of cholinesterases. This feature was used to examine the interaction of a second enzyme – butyrylcholinesterase (BChE) – with the BZE-AChE. Evidence for the specificity of this interaction was provided by two further experiments, i.e. BChE has no affinity towards Propidium and the binding of BChE towards BZE-AChE could be blocked by excess cocaine. Thus the successful integration of recognition elements on the molecular level could be demonstrated. The propidium-modifies sensor allowed the construction of a scaffold of cholinesterases that interact via different recognition sites. Unmodified and BZE-coupled AChE can be immobilized on the EQCM-sensor via the interaction with propidium. With cocaine being a substrate BChE this compound cannot only be used to capture anti-BZE-antibodies, but also as a recognition element for BChE. The affinity of the BChE towards is relatively low as compared to the antibody’s binding strength, thus making it difficult to employ this system for analytical purposes. Still the concept presented herein can be extended by other ligand-enzyme-combinations. On the basis of “simple” molecular recognition elements this enables the development of “multifunctional” recognition element systems. This work could show that the construction of such complex systems is possible without cutting back with regard to the sensitivity of the individual assays. KW - bifunktionaler Sensor KW - Kokain KW - Organophosphate KW - Acetylcholinesterase KW - Antikörper KW - bifunctional sensor KW - cocaine KW - organophosphate KW - acetylcholinesterase KW - antibody Y1 - 2008 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus-25021 ER - TY - THES A1 - Heilmann, Katja T1 - Wechselwirkungen von Immunzellen mit synthetischen und biomimetischen Oberflächen T1 - Interactions of immune cells with synthetic and biomimetic surfaces N2 - Die vorliegende Arbeit wurde im Zeitraum von Oktober 2002 bis November 2005 an dem Institut für Biochemie und Biologie der Universität Potsdam in Kooperation mit dem Institut für Chemie des GKSS Forschungszentrums in Teltow unter der Leitung von Herrn Prof. Dr. B. Micheel und Herrn Prof. Dr. Th. Groth angefertigt. Im Rahmen dieser Arbeit wurden die Wechselwirkungen von Immunzellen mit verschiedenen Kultursubstraten untersucht. Dafür wurden drei verschiedene Hybridomzelllinien eingesetzt. Eine Hybridomzelllinie (K2) ist im Laufe dieser Arbeit hergestellt und etabliert worden. Der Einsatz von synthetischen und proteinbeschichteten Kulturoberflächen führte bei Hybridomzellen zu einer deutlich gesteigerten Antikörpersynthese im Vergleich zu herkömmlichen Zellkulturmaterialien. Obwohl diese Zellen in der Regel als Suspensionszellen kultiviert werden, führten die eingesetzten Polymermembranen (PAN, NVP) zu einer verbesserten Antikörpersynthese (um 30%) gegenüber Polystyrol als Referenz. Es konnte gezeigt werden, dass es einen Zusammenhang zwischen der Produktivität und dem Adh asionsverhalten der Hybridomzellen gibt. Um den Einfluss von Proteinen der extrazellulären Matrix auf Zellwachstum und Antikörpersynthese von Hybridomzellen zu untersuchen, wurden proteinbeschichtete Polystyrol-Oberflächen eingesetzt. Für die Modifikationen wurden Fibronektin, Kollagen I, Laminin und BSA ausgewählt. Die Modifikation der Polystyrol-Oberfläche mit geringen Mengen Fibronektin (0,2-0,4 µg/ml) führte zu einer beträchtlichen Steigerung der Antikörpersynthese um 70-120%. Für Kollagen I- und BSA-Beschichtungen konnten Steigerungen von 40% beobachtet werden. Modifikationen der Polystyrol-Oberfläche mit Laminin zeigten nur marginale Effekte. Durch weitere Versuche wurde bestätigt, dass die Adhäsion der Zellen an Kollagen I- und Laminin-beschichteten Oberflächen verringert ist. Die alpha2-Kette des alpha2beta1-Integrins konnte auf der Zelloberfläche nicht nachgewiesen werden. Durch ihr Fehlen wird wahrscheinlich die Bindungsfähigkeit der Zellen an Kollagen I und Laminin beeinflusst. Durch die Ergebnisse konnte gezeigt werden, dass Hybridomzellen nicht nur Suspensionszellen sind und das Kultursubstrate das Zellwachstum und die Produktivität dieser Zellen stark beeinflussen können. Der Einsatz von synthetischen und proteinbeschichteten Kultursubstraten zur Steigerung der Antikörpersynthese kann damit für die industrielle Anwendung von großer Relevanz sein. Für die Modellierung einer Lymphknotenmatrix wurden Fibronektin, Kollagen I, Heparansulfat und N-Acetylglucosamin-mannose in verschiedenen Kombinationen an Glasoberflächen adsorbiert und für Versuche zur In-vitro-Immunisierung eingesetzt. Es konnte gezeigt werden, dass die Modifikation der Oberflächen die Aktivierung und Interaktion von dendritischen Zellen, T- und B-Lymphozyten begünstigt, was durch den Nachweis spezifischer Interleukine (IL12, IL6) und durch die Synthese spezifischer Antikörper bestätigt wurde. Eine spezifische Immunreaktion gegen das Antigen Ovalbumin konnte mit den eingesetzten Zellpopulationen aus Ovalbumin-T-Zell-Rezeptor-transgenen Mäusen nachgewiesen werden. Die In-vitro-Immunantwort wurde dabei am stärksten durch eine Kombination von Kollagen I, Heparansulfat und N-Acetylglucosamin-mannose auf einer Glasoberfläche gefördert. Die Etablierung einer künstlichen Immunreaktion kann eine gesteuerte Aktivierung bzw. Inaktivierung von körpereigenen dendritischen Zellen gegen bestehende Krankheitsmerkmale in vitro ermöglichen. Durch die Versuche wurden Grundlagen für spezifische Immunantworten erarbeitet, die u.a. für die Herstellung von humanen Antikörpern eingesetzt werden können. N2 - In this scientific work the interactions of immune cells with different culture substrata were investigated. Therefore, three hybridoma cell lines were tested, one cell line (K2) was established during this work. The application of synthetic and protein-coated culture surfaces lead to a significantly increased synthesis of monoclonal antibodies in comparison to usual tissue polystyrene. Although hybridoma cells were normally cultured in suspension applied polymer membranes like PAN and NVP induced an increase by 30%. Furthermore, an influence of cell adhesion and antibody synthesis could be shown. To investigate the influence of extracellular matrix proteins on growth and antibody synthesis of hybridoma cells tissue culture polystyrene was coated with fibronectin, collagen I, laminin and bovine serum albumine in different concentrations. Modifications with fibronectin (concentrations between 0.2 and 0.4 µg/ml) improved the yield of monoclonal antibodies considerably by 70-120%. Coating cell culture plates with collagen I and bovine serum albumine induced an increase by 40%. The coating with laminin showed only marginal effects. Further experiments approved a decreased adhesion of hybridoma cells on collagen I and laminin coated surfaces. FACS analysis showed a reduced presence of the alpha2-chain of the alpha2/beta1-integrin responsible for mediating the binding to collagen I and laminin. Probably, the binding affinity to collagen I and laminin coated surfaces was influenced by this. The results showed a high impact of modified culture substrata on antibody synthesis even if hybridoma cells were cultured in suspension normally and this could be an approach for industrial application. The second part of this work comprised the creation of a lymph node paracortex related surface. Different matrix proteins like fibronectin, collagen I, heparane sulfate and a sugar named N-acetylglucosamine-mannose were coated in different combinations on glass surfaces to create a matrix. Dendritic cells were cultivated on these surfaces and get activated with ovalbumin. After that naïve T- and B-cell populations were added and it could be shown nicely that the modifications of the culture surface were essential for activation and interaction of dendritic cells, T- and B-cells which resulted in the secretion of specific interleukins (IL12, IL6) and specific antibodies (anti-ovalbumin-antibodies). In these experiments a specific immune respone to ovalbumin in vitro could be detected if the cells were isolated from ovalbumin-receptor-transgenic-mice (TgNDO11.10). This In-vitro-immunization was triggered at most if cells were cultured on a surface coated with a combination of collagen I, heparane sulfate and N-acetylglucosamine-mannose. These experiments could be basics for controlled specific immune reactions in vitro which could be used for the production of human antibodies or for the controlled activation or inactivation of immune cells. KW - Hybridomtechnik KW - Antikörper KW - Extrazelluläre Matrix KW - Antikörperproduktion KW - Adhäsion KW - Polymermembranen KW - adhesion KW - polymer membranes KW - hybridoma cells KW - antibody synthesis Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus-8843 ER -