TY - JOUR A1 - Helm, Norman A1 - Prieske, Olaf A1 - Mühlbauer, Thomas A1 - Krüger, Tom A1 - Chaabene, Helmi A1 - Granacher, Urs T1 - Validation of a new judo-specific ergometer system in male elite and sub-elite athletes JF - Journal of sports science & medicine N2 - Our experimental approach included two studies to determine discriminative validity and test-retest reliability (study 1) as well as ecological validity (study 2) of a judo ergometer system while performing judo-specific movements. Sixteen elite (age: 23 +/- 3 years) and 11 sub-elite (age: 16 +/- 1 years) athletes participated in study 1 and 14 male sub-elite judo athletes participated in study 2. Discriminative validity and test-retest reliability of sport-specific parameters (mechanical work, maximal force) were assessed during pulling movements with and without tsukuri (kuzushi). Ecological validity of muscle activity was determined by performing pulling movements using the ergometer without tsukuri and during the same movements against an opponent. In both conditions, electromyographic activity of trunk (e.g., m. erector spinae) and upper limb muscles (e.g., m. biceps brachii) were assessed separately for the lifting and pulling arm. Elite athletes showed mostly better mechanical work, maximal force, and power (0.12 <= d <= 1.80) compared with sub-elite athletes. The receiver operating characteristic analysis revealed acceptable validity of the JERGo(C) system to discriminate athletes of different performance levels predominantly during kuzushi without tsukuri (area under the curve = 0.27-0.90). Moreover, small-to-medium discriminative validity was found to detect meaningful performance changes for mechanical work and maximal force. The JERGo(C) system showed small-to-high relative (ICC = 0.37-0.92) and absolute reliability (SEM = 10.8-18.8%). Finally, our analyses revealed acceptable correlations (r = 0.41-0.88) between muscle activity during kuzushi performed with the JERGo(C) system compared with a judo opponent. Our findings indicate that the JERGo(C) system is a valid and reliable test instrument for the assessment and training of judo-specific pulling kinetics particularly during kuzushi movement without tsukuri. KW - Judo-specific pulling movement KW - work KW - force KW - muscle activity KW - reliability Y1 - 2018 SN - 1303-2968 VL - 17 IS - 3 SP - 465 EP - 474 PB - Department of Sports Medicine, Medical Faculty of Uludag University CY - Bursa ER - TY - JOUR A1 - Quarmby, Andrew James A1 - Khajooei, Mina A1 - Kurtz, Philip A1 - Henschke, Jakob A1 - Kim, MyoungHwee A1 - Mayer, Frank A1 - Engel, Tilman T1 - Unexpected running perturbations BT - reliability and validity of a treadmill running protocol with analysis of provoked reflex activity in the lower extremities JF - Frontiers in sports and active living N2 - Introduction Balance is vital for human health and experiments have been conducted to measure the mechanisms of postural control, for example studying reflex responses to simulated perturbations. Such studies are frequent in walking but less common in running, and an understanding of reflex responses to trip-like disturbances could enhance our understanding of human gait and improve approaches to training and rehabilitation. Therefore, the primary aim of this study was to investigate the technical validity and reliability of a treadmill running protocol with perturbations. A further exploratory aim was to evaluate the associated neuromuscular reflex responses to the perturbations, in the lower limbs. Methods Twelve healthy participants completed a running protocol (9 km/h) test-retest (2 weeks apart), whereby 30 unilateral perturbations were executed via the treadmill belts (presets:2.0 m/s amplitude;150 ms delay (post-heel contact);100ms duration). Validity of the perturbations was assessed via mean +/- SD comparison, percentage error calculation between the preset and recorded perturbation characteristics (PE%), and coefficient of variation (CV%). Test-retest reliability (TRV%) and Bland-Altman analysis (BLA; bias +/- 1.96 * SD) was calculated for reliability. To measure reflex activity, electromyography (EMG) was applied in both legs. EMG amplitudes (root mean square normalized to unperturbed strides) and latencies [ms] were analysed descriptively. Results Left-side perturbation amplitude was 1.9 +/- 0.1 m/s, delay 105 +/- 2 ms, and duration 78 +/- 1 ms. Right-side perturbation amplitude was 1.9 +/- 0.1 m/s, delay 118 +/- 2 ms, duration 78 +/- 1 ms. PE% ranged from 5-30% for the recorded perturbations. CV% of the perturbations ranged from 19.5-76.8%. TRV% for the perturbations was 6.4-16.6%. BLA for the left was amplitude: 0.0 +/- 0.3m/s, delay: 0 +/- 17 ms, duration: 2 +/- 13 ms, and for the right was amplitude: 0.1 +/- 0.7, delay: 4 +/- 40 ms, duration: 1 +/- 35 ms. EMG amplitudes ranged from 175 +/- 141%-454 +/- 359% in both limbs. Latencies were 109 +/- 12-116 +/- 23 ms in the tibialis anterior, and 128 +/- 49-157 +/- 20 ms in the biceps femoris. Discussion Generally, this study indicated sufficient validity and reliability of the current setup considering the technical challenges and limitations, although the reliability of the right-sided perturbations could be questioned. The protocol provoked reflex responses in the lower extremities, especially in the leading leg. Acute neuromusculoskeletal adjustments to the perturbations could be studied and compared in clinical and healthy running populations, and the protocol could be utilised to monitor chronic adaptations to interventions over time. KW - running KW - perturbation KW - EMG KW - reliability KW - stumbling KW - reflexes KW - split-belt treadmill KW - gait Y1 - 2023 U6 - https://doi.org/10.3389/fspor.2023.1129058 SN - 2624-9367 VL - 5 PB - Frontiers Media CY - Lausanne ER - TY - JOUR A1 - Jannasch, Franziska A1 - Nickel, Daniela A1 - Schulze, Matthias Bernd T1 - The reliability and relative validity of predefined dietary patterns were higher than that of exploratory dietary patterns in the European Prospective Investigation into Cancer and Nutrition (EPIC)-Potsdam population JF - British journal of nutrition : BJN : an international journal of nutritional science / published on behalf of The Nutrition Society N2 - The aim of this study was to assess the ability of the FFQ to describe reliable and valid dietary pattern (DP) scores. In a total of 134 participants of the European Prospective Investigation into Cancer and Nutrition-Potsdam study aged 35-67 years, the FFQ was applied twice (baseline and after 1 year) to assess its reliability. Between November 1995 and March 1997, twelve 24-h dietary recalls (24HDR) as reference instrument were applied to assess the validity of the FFQ. Exploratory DP were derived by principal component analyses. Investigated predefined DP were the Alternative Healthy Eating Index (AHEI) and two Mediterranean diet indices. From dietary data of each FFQ, two exploratory DP were retained, but differed in highly loading food groups, resulting in moderate correlations (r 0 center dot 45-0 center dot 58). The predefined indices showed higher correlations between the FFQ (r(AHEI) 0 center dot 62, r(Mediterranean Diet Pyramid Index (MedPyr)) 0 center dot 62 and r(traditional Mediterranean Diet Score (tMDS)) 0 center dot 51). From 24HDR dietary data, one exploratory DP retained differed in composition to the first FFQ-based DP, but showed similarities to the second DP, reflected by a good correlation (r 0 center dot 70). The predefined DP correlated moderately (r 0 center dot 40-0 center dot 60). To conclude, long-term analyses on exploratory DP should be interpreted with caution, due to only moderate reliability. The validity differed extensively for the two exploratory DP. The investigated predefined DP showed a better reliability and a moderate validity, comparable to other studies. Within the two Mediterranean diet indices, the MedPyr performed better than the tMDs in this middle-aged, semi-urban German study population. KW - dietary patterns KW - reliability KW - validity Y1 - 2020 U6 - https://doi.org/10.1017/S0007114520003517 SN - 1475-2662 SN - 0007-1145 VL - 125 IS - 11 SP - 1270 EP - 1280 PB - Cambridge University Press CY - Cambridge ER - TY - JOUR A1 - Kather, Fritz A1 - Hadzic, Miralem A1 - Hehle, Teresa A1 - Eichler, Sarah A1 - Klein, Julia A1 - Völler, Heinz A1 - Salzwedel, Annett T1 - Test-retest reliability of the Mini Nutritional Assessment- Short Form (MNA-SF) in older patients undergoing cardiac rehabilitation JF - Journal of geriatric cardiology KW - Cardiac rehabilitation KW - Malnutrition KW - Octogenarians KW - Test-retest KW - reliability Y1 - 2020 U6 - https://doi.org/10.11909/j.issn.1671-5411.2020.09.007 SN - 1671-5411 VL - 17 IS - 9 SP - 574 EP - 579 PB - English China Online Journals, ECOJ CY - Windsor [u.a.] ER - TY - JOUR A1 - Dobberke, Jeanette A1 - Baritello, Omar A1 - Hadzic, Miralem A1 - Völler, Heinz A1 - Eichler, Sarah A1 - Salzwedel, Annett T1 - Test-retest reliability of center of pressure measures for postural control assessment in older cardiac patients JF - Gait & posture : official journal of Gait and Clinical Movement Analysis Society (GCMAS) and European Society of Movement Analysis in Adults and Children (ESMAC) N2 - Background Elderly patients are a growing population in cardiac rehabilitation (CR). As postural control declines with age, assessment of impaired balance is important in older CR patients in order to predict fall risk and to initiate counteracting steps. Functional balance tests are subjective and lack adequate sensitivity to small differences, and are further subject to ceiling effects. A quantitative approach to measure postural control on a continuous scale is therefore desirable. Force plates are already used for this purpose in other clinical contexts, therefore could be a promising tool also for older CR patients. However, in this population the reliability of the assessment is not fully known. Research question Analysis of test-retest reliability of center of pressure (CoP) measures for the assessment of postural control using a force plate in older CR patients. Methods 156 CR patients (> 75 years) were enrolled. CoP measures (path length (PL), mean velocity (MV), and 95% confidence ellipse area (95CEA)) were analyzed twice with an interval of two days in between (bipedal narrow stance, eyes open (EO) and closed (EC), three trials for each condition, 30 s per trial), using a force plate. For test-retest reliability estimation absolute differences (& UDelta;: T0-T1), intraclass correlation coefficients (ICC) with 95% confidence intervals, standard error of measurement and minimal detectable change were calculated. Results Under EO condition ICC were excellent for PL and MV (0.95) and good for 95CEA (0.88) with & UDelta; of 10.1 cm (PL), 0.3 cm/sec (MV) and 1.5 cm(2 )(95CEA) respectively. Under EC condition ICC were excellent (> 0.95) for all variables with larger & UDelta; (PL: 21.7 cm; MV: 0.7 cm/sec; 95CEA: 2.4 cm(2)) Significance In older CR patients, the assessment of CoP measures using a force plate shows good to excellent test retest reliability. KW - Cardiac rehabilitation KW - Older patients KW - Postural control KW - Test-retest KW - reliability KW - Force plate Y1 - 2022 U6 - https://doi.org/10.1016/j.gaitpost.2021.12.011 SN - 0966-6362 SN - 1879-2219 VL - 92 SP - 359 EP - 363 PB - Elsevier Science CY - Amsterdam ER - TY - JOUR A1 - Chen, Junchao A1 - Lange, Thomas A1 - Andjelkovic, Marko A1 - Simevski, Aleksandar A1 - Lu, Li A1 - Krstić, Miloš T1 - Solar particle event and single event upset prediction from SRAM-based monitor and supervised machine learning JF - IEEE transactions on emerging topics in computing / IEEE Computer Society, Institute of Electrical and Electronics Engineers N2 - The intensity of cosmic radiation may differ over five orders of magnitude within a few hours or days during the Solar Particle Events (SPEs), thus increasing for several orders of magnitude the probability of Single Event Upsets (SEUs) in space-borne electronic systems. Therefore, it is vital to enable the early detection of the SEU rate changes in order to ensure timely activation of dynamic radiation hardening measures. In this paper, an embedded approach for the prediction of SPEs and SRAM SEU rate is presented. The proposed solution combines the real-time SRAM-based SEU monitor, the offline-trained machine learning model and online learning algorithm for the prediction. With respect to the state-of-the-art, our solution brings the following benefits: (1) Use of existing on-chip data storage SRAM as a particle detector, thus minimizing the hardware and power overhead, (2) Prediction of SRAM SEU rate one hour in advance, with the fine-grained hourly tracking of SEU variations during SPEs as well as under normal conditions, (3) Online optimization of the prediction model for enhancing the prediction accuracy during run-time, (4) Negligible cost of hardware accelerator design for the implementation of selected machine learning model and online learning algorithm. The proposed design is intended for a highly dependable and self-adaptive multiprocessing system employed in space applications, allowing to trigger the radiation mitigation mechanisms before the onset of high radiation levels. KW - Machine learning KW - Single event upsets KW - Random access memory KW - monitoring KW - machine learning algorithms KW - predictive models KW - space missions KW - solar particle event KW - single event upset KW - machine learning KW - online learning KW - hardware accelerator KW - reliability KW - self-adaptive multiprocessing system Y1 - 2022 U6 - https://doi.org/10.1109/TETC.2022.3147376 SN - 2168-6750 VL - 10 IS - 2 SP - 564 EP - 580 PB - Institute of Electrical and Electronics Engineers CY - [New York, NY] ER - TY - JOUR A1 - Sumpf, Bernd A1 - Maiwald, Martin A1 - Muller, Andre A1 - Ginolas, Arnim A1 - Haeusler, Karl A1 - Erbert, Goetz A1 - Traenkle, Guenther T1 - Reliable operation for 14 500 h of a wavelength-stabilized Diode Laser System on a Microoptical Bench at 671 nm JF - IEEE transactions on components, packaging and manufacturing technology N2 - Reliability tests for wavelength-stabilized compact diode laser systems emitting at 671 nm are presented. The devices were mounted on microoptical benches with the dimensions of 13 mm x 4 mm. Reflecting Bragg gratings were used for wavelength stabilization and emission width narrowing. The reliability tests were performed at 25 degrees C and at an output power up to 10 mW per micrometer stripe width of the gain medium. Reliable operation could be demonstrated over a test time up to 14 500 h at an output power up to 1.0 W. Environmental tests using random vibrations with acceleration up to 29 g were performed without deterioration of the devices. KW - High-power lasers KW - laser resonators KW - Raman spectroscopy KW - reliability KW - semiconductor lasers Y1 - 2012 U6 - https://doi.org/10.1109/TCPMT.2011.2171342 SN - 2156-3950 VL - 2 IS - 1 SP - 116 EP - 121 PB - Inst. of Electr. and Electronics Engineers CY - Piscataway ER - TY - GEN A1 - Krstić, Miloš A1 - Jentzsch, Anne-Kristin T1 - Reliability, safety and security of the electronics in automated driving vehicles - joint lab lecturing approach T2 - 2018 12TH European Workshop on Microelectronics Education (EWME) N2 - This paper proposes an education approach for master and bachelor students to enhance their skills in the area of reliability, safety and security of the electronic components in automated driving. The approach is based on the active synergetic work of research institutes, academia and industry in the frame of joint lab. As an example, the jointly organized summer school with the respective focus is organized and elaborated. KW - reliability KW - safety KW - security KW - automated driving KW - joint lab Y1 - 2018 SN - 978-1-5386-1157-9 SP - 21 EP - 22 PB - IEEE CY - New York ER - TY - JOUR A1 - Bisi-Balogun, Adebisi A1 - Cassel, Michael A1 - Mayer, Frank T1 - Reliability of Various Measurement Stations for Determining Plantar Fascia Thickness and Echogenicity JF - Diagnostics : open access journal N2 - This study aimed to determine the relative and absolute reliability of ultrasound (US) measurements of the thickness and echogenicity of the plantar fascia (PF) at different measurement stations along its length using a standardized protocol. Twelve healthy subjects (24 feet) were enrolled. The PF was imaged in the longitudinal plane. Subjects were assessed twice to evaluate the intra-rater reliability. A quantitative evaluation of the thickness and echogenicity of the plantar fascia was performed using Image J, a digital image analysis and viewer software. A sonography evaluation of the thickness and echogenicity of the PF showed a high relative reliability with an Intra class correlation coefficient of 0.88 at all measurement stations. However, the measurement stations for both the PF thickness and echogenicity which showed the highest intraclass correlation coefficient (ICCs) did not have the highest absolute reliability. Compared to other measurement stations, measuring the PF thickness at 3 cm distal and the echogenicity at a region of interest 1 cm to 2 cm distal from its insertion at the medial calcaneal tubercle showed the highest absolute reliability with the least systematic bias and random error. Also, the reliability was higher using a mean of three measurements compared to one measurement. To reduce discrepancies in the interpretation of the thickness and echogenicity measurements of the PF, the absolute reliability of the different measurement stations should be considered in clinical practice and research rather than the relative reliability with the ICC. KW - plantar fascia KW - reliability KW - sonography KW - musculoskeletal Y1 - 2016 U6 - https://doi.org/10.3390/diagnostics6020015 SN - 2075-4418 VL - 6 SP - 506 EP - 519 PB - MDPI CY - Basel ER - TY - JOUR A1 - Risch, Lucie A1 - Wochatz, Monique A1 - Messerschmidt, Janin A1 - Engel, Tilman A1 - Mayer, Frank A1 - Cassel, Michael T1 - Reliability of evaluating achilles tendon vascularization assessed with doppler ultrasound advanced dynamic flow JF - Journal of ultrasound in medicine N2 - The reliability of quantifying intratendinous vascularization by high-sensitivity Doppler ultrasound advanced dynamic flow has not been examined yet. Therefore, this study aimed to investigate the intraobserver and interobserver reliability of evaluating Achilles tendon vascularization by advanced dynamic flow using established scoring systems. Methods-Three investigators evaluated vascularization in 67 recordings in a test-retest design, applying the Ohberg score, a modified Ohberg score, and a counting score. Intraobserver and interobserver agreement for the Ohberg score and modified Ohberg score was analyzed by the Cohen kappa and Fleiss kappa coefficients (absolute), Kendall tau b coefficient, and Kendall coefficient of concordance (W; relative). The reliability of the counting score was analyzed by intraclass correlation coefficients (ICC) 2.1 and 3.1, the standard error of measurement (SEM), and Bland-Altman analysis (bias and limits of agreement [LoA]). Results-Intraobserver and interobserver agreement (absolute/relative) ranged from 0.61 to 0.87/0.87 to 0.95 and 0.11 to 0.66/0.76 to 0.89 for the Ohberg score and from 0.81 to 0.87/0.92 to 0.95 and 0.64 to 0.80/0.88 to 0.93 for the modified Ohberg score, respectively. The counting score revealed an intraobserver ICC of 0.94 to 0.97 (SEM, 1.0-1.5; bias, -1; and LoA, 3-4 vessels). The interobserver ICC for the counting score ranged from 0.91 to 0.98 (SEM, 1.0-1.9; bias, 0; and LoA, 3-5 vessels). Conclusions-The modified Ohberg score and counting score showed excellent reliability and seem convenient for research and clinical practice. The Ohberg score revealed decent intraobserver but unexpected low interobserver reliability and therefore cannot be recommended. KW - advanced dynamic flow KW - intratendinous blood flow KW - musculoskeletal KW - reliability KW - ultrasound Y1 - 2017 U6 - https://doi.org/10.1002/jum.14414 SN - 0278-4297 SN - 1550-9613 VL - 37 IS - 3 SP - 737 EP - 744 PB - Wiley CY - Hoboken ER -