TY - JOUR A1 - Zhang, Xiaorong A1 - Caserta, Giorgio A1 - Yarman, Aysu A1 - Supala, Eszter A1 - Tadjoung Waffo, Armel Franklin A1 - Wollenberger, Ulla A1 - Gyurcsanyi, Robert E. A1 - Zebger, Ingo A1 - Scheller, Frieder W. T1 - "Out of Pocket" protein binding BT - a dilemma of epitope imprinted polymers revealed for human hemoglobin JF - Chemosensors N2 - The epitope imprinting approach applies exposed peptides as templates to synthesize Molecularly Imprinted Polymers (MIPs) for the recognition of the parent protein. While generally the template protein binding to such MIPs is considered to occur via the epitope-shaped cavities, unspecific interactions of the analyte with non-imprinted polymer as well as the detection method used may add to the complexity and interpretation of the target rebinding. To get new insights on the effects governing the rebinding of analytes, we electrosynthesized two epitope-imprinted polymers using the N-terminal pentapeptide VHLTP-amide of human hemoglobin (HbA) as the template. MIPs were prepared either by single-step electrosynthesis of scopoletin/pentapeptide mixtures or electropolymerization was performed after chemisorption of the cysteine extended VHLTP peptide. Rebinding of the target peptide and the parent HbA protein to the MIP nanofilms was quantified by square wave voltammetry using a redox probe gating, surface enhanced infrared absorption spectroscopy, and atomic force microscopy. While binding of the pentapeptide shows large influence of the amino acid sequence, all three methods revealed strong non-specific binding of HbA to both polyscopoletin-based MIPs with even higher affinities than the target peptides. KW - Molecularly Imprinted Polymers KW - epitope imprinting KW - non-specific KW - binding KW - redox gating KW - SEIRA spectroelectrochemistry Y1 - 2021 U6 - https://doi.org/10.3390/chemosensors9060128 SN - 2227-9040 VL - 9 IS - 6 PB - MDPI CY - Basel ER - TY - JOUR A1 - Othman, Abdelmageed M. A1 - Wollenberger, Ulla T1 - Amperometric biosensor based on coupling aminated laccase to functionalized carbon nanotubes for phenolics detection JF - International journal of biological macromolecules N2 - A biosensor for phenolic compounds based on a chemically modified laccase from Coriolus hirsula immobilized on functionalized screen-printed carbon electrodes (SPCEs) was achieved. Different enzyme modifications and immobilization strategies were analyzed. The electrochemical response of the immobilized laccase on SPCEs modified with carboxyl functionalized multi-walled carbon nanotubes (COOH-MWCNT) was the highest when laccase was aminated prior to the adsorption onto the working electrode. The developed lactase biosensor sensitivity toward different phenolic compounds was assessed to determine the biosensor response with several phenolic compounds. The highest response was obtained for ABTS with a saturation value of I-max = 27.94 mu A. The electrocatalytic efficiency (I-max/K-m(app)) was the highest for ABTS (5588 mu A mu M-1) followed by syringaldazine (3014 mu A.mu M-1). The sensors were considerably stable, whereby 99.5, 82 and 77% of the catalytic response using catechol as substrate was retained after 4, 8 and 10 successive cycles of reuse respectively, with response time average of 5 s for 12 cycles. No loss of activity was observed after 20 days of storage. KW - amperometry KW - laccase KW - amination KW - biosensor KW - carbon nanotubes KW - phenols Y1 - 2020 U6 - https://doi.org/10.1016/j.ijbiomac.2020.03.049 SN - 0141-8130 SN - 1879-0003 VL - 153 SP - 855 EP - 864 PB - Elsevier CY - New York, NY [u.a.] ER - TY - JOUR A1 - Jetzschmann, Katharina J. A1 - Tank, Steffen A1 - Jagerszki, Gyula A1 - Gyurcsanyi, Robert E. A1 - Wollenberger, Ulla A1 - Scheller, Frieder W. T1 - Bio-Electrosynthesis of Vectorially Imprinted Polymer Nanofilms for Cytochrome P450cam JF - ChemElectroChem N2 - A new approach for synthesizing a vectorially imprinted polymer (VIP) is presented for the microbial cytochrome P450cam enzyme. A surface attached binding motif of a natural reaction partner of the target protein, putidaredoxin (Pdx), is the anchor to the underlying transducer. The 15 amino acid peptide anchor, which stems from the largest continuous amino acid chain within the binding site of Pdx was modified: (i) internal cysteines were replaced by serines to prevent disulfide bond formation; (ii) 2 ethylene glycol units were attached to the N-terminus as a spacer region; and (iii) an N-terminal cysteine was added to allow the immobilization on the gold electrode surface. Immobilization on GCE was achieved via an N-(1-pyrenyl)maleimide (NPM) cross-linker. In this way oriented immobilization of P450cam was accomplished by binding it to a peptide-modified gold or glassy carbon electrode (GCE) prior to the electrosynthesis of a polymer nanofilm around the immobilized target. This VIP nanofilm enabled reversible oriented docking of P450cam as it is indicated by the catalytic oxygen reduction via direct electron transfer between the enzyme and the underlying electrode. Catalysis of oxygen reduction by P450cam bound to the VIP-modified GCE was used to measure rebinding to the VIP. The mild coupling of an oxidoreductase with the electrode may be appropriate for realizing electrode-driven substrate conversion by instable P450 enzymes without the need of NADPH co-factor. KW - cytochrome P450 KW - direct electron transfer KW - electropolymerization KW - molecularly imprinted polymers KW - protein imprinting Y1 - 2019 U6 - https://doi.org/10.1002/celc.201801851 SN - 2196-0216 VL - 6 IS - 6 SP - 1818 EP - 1823 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Neumann, Bettina A1 - Kielb, Patrycja A1 - Rustam, Lina A1 - Fischer, Anna A1 - Weidinger, Inez M. A1 - Wollenberger, Ulla T1 - Bioelectrocatalytic Reduction of Hydrogen Peroxide by Microperoxidase-11 Immobilized on Mesoporous Antimony-Doped Tin Oxide JF - ChemElectrChem N2 - The heme-undecapeptide microperoxidase-11 (MP-11) was immobilized on mesoporous antimony-doped tin oxide (ATO) thin-film electrodes modified with the positively charged binding promotor polydiallyldimethylammonium chloride. Surface concentrations of MP-11 of 1.5 nmol cm(-2) were sufficiently high to enable spectroelectrochemical analyses. UV/Vis spectroscopy and resonance Raman spectroscopy revealed that immobilized MP-11 adopts a six-coordinated low-spin conformation, as in solution in the presence of a polycation. Cathodic reduction of hydrogen peroxide at potentials close to +500mV versus Ag/AgCl indicates that the reaction proceeds via a Compound I-type like intermediate, analogous to natural peroxidases, and confirms mesoporous ATO as a suitable host material for adsorbing the heme-peptide in its native state. A hydrogen peroxide sensor is proposed by using the bioelectrocatalytic properties of the MP-11-modified ATO. KW - electrochemistry KW - enzyme catalysis KW - mesoporous materials KW - microperoxidase KW - spectroelectrochemistry Y1 - 2017 U6 - https://doi.org/10.1002/celc.201600776 SN - 2196-0216 VL - 4 IS - 4 SP - 913 EP - 919 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Hassan, Rabeay Y. A. A1 - Wollenberger, Ulla T1 - Direct determination of bacterial cell viability using carbon nanotubes modified screen-printed electrodes JF - Electroanalysis : an international journal devoted to fundamental and practical aspects of electroanalysis N2 - For the early detection of bacterial infection, there is a need for rapid, sensitive, and label-free assays. Thus, in this study, nanostrucured microbial electrochemical platform is designed to monitor the viability and cell growth of S. aureus. Using multi-walled carbon nanotube modified screen-printed electrodes (MWCNTs/SPE), the cyclic voltammetric measurements showed only one irreversible oxidation peak at 600 mV vs Ag/AgCl that accounts for the viable and metabolically active bacterial cells. The assay was optimized and the secreted metabolites, in the extracellular matrix, were directly detected. The peak current showed a positive correlation with viable cell numbers ranging from OD600 nm of 0.1 to 1.1, indicating that the activity of live cells can be quantified. Consequently, responses of viable and non-viable cells of S. aureus to the effects of antibiotic and respiratory chain inhibitors were determined. Thus, the proposed nanostructure-based bacterial sensor provides a reasonable and reliable way for real-time monitoring of live-dead cell functions, and antibacterial profiling. KW - Bacterial biosensor KW - cell viability assay KW - screen printed electrodes (SPEs) KW - carbon nanotubes (CNTs) Y1 - 2019 U6 - https://doi.org/10.1002/elan.201900047 SN - 1040-0397 SN - 1521-4109 VL - 31 IS - 6 SP - 1112 EP - 1117 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Badalyan, Artavazd A1 - Dierich, Marlen A1 - Stiba, Konstanze A1 - Schwuchow, Viola A1 - Leimkühler, Silke A1 - Wollenberger, Ulla T1 - Electrical wiring of the aldehyde oxidoreductase PaoABC with a polymer containing osmium redox centers BT - biosensors for benzaldehyde and GABA JF - Biosensors N2 - Biosensors for the detection of benzaldehyde and g-aminobutyric acid (GABA) are reported using aldehyde oxidoreductase PaoABC from Escherichia coli immobilized in a polymer containing bound low potential osmium redox complexes. The electrically connected enzyme already electrooxidizes benzaldehyde at potentials below −0.15 V (vs. Ag|AgCl, 1 M KCl). The pH-dependence of benzaldehyde oxidation can be strongly influenced by the ionic strength. The effect is similar with the soluble osmium redox complex and therefore indicates a clear electrostatic effect on the bioelectrocatalytic efficiency of PaoABC in the osmium containing redox polymer. At lower ionic strength, the pH-optimum is high and can be switched to low pH-values at high ionic strength. This offers biosensing at high and low pH-values. A “reagentless” biosensor has been formed with enzyme wired onto a screen-printed electrode in a flow cell device. The response time to addition of benzaldehyde is 30 s, and the measuring range is between 10–150 µM and the detection limit of 5 µM (signal to noise ratio 3:1) of benzaldehyde. The relative standard deviation in a series (n = 13) for 200 µM benzaldehyde is 1.9%. For the biosensor, a response to succinic semialdehyde was also identified. Based on this response and the ability to work at high pH a biosensor for GABA is proposed by coimmobilizing GABA-aminotransferase (GABA-T) and PaoABC in the osmium containing redox polymer. KW - redox polymer KW - aldehyde oxidoreductase KW - ionic strength KW - benzaldehyde KW - GABA KW - biosensor Y1 - 2014 U6 - https://doi.org/10.3390/bios4040403 VL - 4 IS - 4 SP - 403 EP - 421 PB - MDPI CY - Basel ER - TY - GEN A1 - Badalyan, Artavazd A1 - Dierich, Marlen A1 - Stiba, Konstanze A1 - Schwuchow, Viola A1 - Leimkühler, Silke A1 - Wollenberger, Ulla T1 - Electrical wiring of the aldehyde oxidoreductase PaoABC with a polymer containing osmium redox centers BT - biosensors for benzaldehyde and GABA T2 - Postprints der Universität Potsdam : Mathematisch-Naturwissenschaftliche Reihe N2 - Biosensors for the detection of benzaldehyde and g-aminobutyric acid (GABA) are reported using aldehyde oxidoreductase PaoABC from Escherichia coli immobilized in a polymer containing bound low potential osmium redox complexes. The electrically connected enzyme already electrooxidizes benzaldehyde at potentials below −0.15 V (vs. Ag|AgCl, 1 M KCl). The pH-dependence of benzaldehyde oxidation can be strongly influenced by the ionic strength. The effect is similar with the soluble osmium redox complex and therefore indicates a clear electrostatic effect on the bioelectrocatalytic efficiency of PaoABC in the osmium containing redox polymer. At lower ionic strength, the pH-optimum is high and can be switched to low pH-values at high ionic strength. This offers biosensing at high and low pH-values. A “reagentless” biosensor has been formed with enzyme wired onto a screen-printed electrode in a flow cell device. The response time to addition of benzaldehyde is 30 s, and the measuring range is between 10–150 µM and the detection limit of 5 µM (signal to noise ratio 3:1) of benzaldehyde. The relative standard deviation in a series (n = 13) for 200 µM benzaldehyde is 1.9%. For the biosensor, a response to succinic semialdehyde was also identified. Based on this response and the ability to work at high pH a biosensor for GABA is proposed by coimmobilizing GABA-aminotransferase (GABA-T) and PaoABC in the osmium containing redox polymer. T3 - Zweitveröffentlichungen der Universität Potsdam : Mathematisch-Naturwissenschaftliche Reihe - 1082 KW - redox polymer KW - aldehyde oxidoreductase KW - ionic strength KW - benzaldehyde KW - GABA KW - biosensor Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-475070 SN - 1866-8372 IS - 1082 ER - TY - JOUR A1 - Neumann, Bettina A1 - Wollenberger, Ulla T1 - Electrochemical biosensors employing natural and artificial heme peroxidases on semiconductors JF - Sensors N2 - Heme peroxidases are widely used as biological recognition elements in electrochemical biosensors for hydrogen peroxide and phenolic compounds. Various nature-derived and fully synthetic heme peroxidase mimics have been designed and their potential for replacing the natural enzymes in biosensors has been investigated. The use of semiconducting materials as transducers can thereby offer new opportunities with respect to catalyst immobilization, reaction stimulation, or read-out. This review focuses on approaches for the construction of electrochemical biosensors employing natural heme peroxidases as well as various mimics immobilized on semiconducting electrode surfaces. It will outline important advances made so far as well as the novel applications resulting thereof. KW - electrochemical biosensors KW - heme KW - peroxidases KW - semiconductors KW - peroxidase mimics Y1 - 2020 U6 - https://doi.org/10.3390/s20133692 SN - 1424-8220 VL - 20 IS - 13 PB - MDPI CY - Basel ER - TY - JOUR A1 - Ozcelikay, Goksu A1 - Kurbanoglu, Sevinc A1 - Zhang, Xiaorong A1 - Söz, Çağla Kosak A1 - Wollenberger, Ulla A1 - Ozkan, Sibel A. A1 - Yarman, Aysu A1 - Scheller, Frieder W. T1 - Electrochemical MIP Sensor for Butyrylcholinesterase JF - Polymers N2 - Molecularly imprinted polymers (MIPs) mimic the binding sites of antibodies by substituting the amino acid-scaffold of proteins by synthetic polymers. In this work, the first MIP for the recognition of the diagnostically relevant enzyme butyrylcholinesterase (BuChE) is presented. The MIP was prepared using electropolymerization of the functional monomer o-phenylenediamine and was deposited as a thin film on a glassy carbon electrode by oxidative potentiodynamic polymerization. Rebinding and removal of the template were detected by cyclic voltammetry using ferricyanide as a redox marker. Furthermore, the enzymatic activity of BuChE rebound to the MIP was measured via the anodic oxidation of thiocholine, the reaction product of butyrylthiocholine. The response was linear between 50 pM and 2 nM concentrations of BuChE with a detection limit of 14.7 pM. In addition to the high sensitivity for BuChE, the sensor responded towards pseudo-irreversible inhibitors in the lower mM range. KW - molecularly imprinted polymers KW - biomimetic sensors KW - butyrylcholinesterase KW - o-phenylenediamine KW - rivastigmine Y1 - 2019 U6 - https://doi.org/10.3390/polym11121970 SN - 2073-4360 VL - 11 IS - 12 PB - MDPI CY - Basel ER - TY - GEN A1 - Ozcelikay, Goksu A1 - Kurbanoglu, Sevinc A1 - Zhang, Xiaorong A1 - Söz, Çağla Kosak A1 - Wollenberger, Ulla A1 - Ozkan, Sibel A. A1 - Yarman, Aysu A1 - Scheller, Frieder W. T1 - Electrochemical MIP Sensor for Butyrylcholinesterase T2 - Postprints der Universität Potsdam : Mathematisch-Naturwissenschaftliche Reihe N2 - Molecularly imprinted polymers (MIPs) mimic the binding sites of antibodies by substituting the amino acid-scaffold of proteins by synthetic polymers. In this work, the first MIP for the recognition of the diagnostically relevant enzyme butyrylcholinesterase (BuChE) is presented. The MIP was prepared using electropolymerization of the functional monomer o-phenylenediamine and was deposited as a thin film on a glassy carbon electrode by oxidative potentiodynamic polymerization. Rebinding and removal of the template were detected by cyclic voltammetry using ferricyanide as a redox marker. Furthermore, the enzymatic activity of BuChE rebound to the MIP was measured via the anodic oxidation of thiocholine, the reaction product of butyrylthiocholine. The response was linear between 50 pM and 2 nM concentrations of BuChE with a detection limit of 14.7 pM. In addition to the high sensitivity for BuChE, the sensor responded towards pseudo-irreversible inhibitors in the lower mM range. T3 - Zweitveröffentlichungen der Universität Potsdam : Mathematisch-Naturwissenschaftliche Reihe - 1138 KW - molecularly imprinted polymers KW - biomimetic sensors KW - butyrylcholinesterase KW - o-phenylenediamine KW - rivastigmine Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-501854 SN - 1866-8372 IS - 1138 ER -