TY - JOUR A1 - Sauter, Tilman A1 - Lützow, Karola A1 - Schossig, Michael A1 - Kosmella, Hans A1 - Weigel, Thomas A1 - Kratz, Karl A1 - Lendlein, Andreas T1 - Shape-memory properties of polyetherurethane foams prepared by thermally induced phase separation JF - Advanced engineering materials N2 - In this study, we report the preparation of two structurally different shape-memory polymer foams by thermally induced phase separation (TIPS) from amorphous polyetherurethanes. Foams with either a homogeneous, monomodal, or with a hierarchically structured, bimodal, pore size distribution are obtained by adoption of the cooling protocol. The shape-memory properties have been investigated for both foam structures by cyclic, thermomechanical experiments, while the morphological changes on the micro scale (pore level) have been compared to the macro scale by an in situ micro compression device experiment. The results show that the hierarchically structured foam achieves higher shape-recovery rates and a higher total recovery as compared to the homogeneous foam, which is due to an increased energy storage capability by micro scale bending of the hierarchically structured foam compared to pure compression of the homogeneous foam. Y1 - 2012 U6 - https://doi.org/10.1002/adem.201200127 SN - 1438-1656 VL - 14 IS - 9 SP - 818 EP - 824 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Schneider, Tobias A1 - Kohl, Benjamin A1 - Sauter, Tilman A1 - Kratz, Karl A1 - Lendlein, Andreas A1 - Ertel, Wolfgang A1 - Schulze-Tanzil, Gundula T1 - Influence of fiber orientation in electrospun polymer scaffolds on viability, adhesion and differentiation of articular chondrocytes JF - Clinical hemorheology and microcirculation : blood flow and vessels N2 - Degradable polymers with a tailorable degradation rate might be promising candidate materials for biomaterial-based cartilage repair. In view of the poor intrinsic healing capability of cartilage, implantation of autologous chondrocytes seeded on a biocompatible slow degrading polymer might be an encouraging approach to improve cartilage repair in the future. This study was undertaken to test if the fiber orientation (random versus aligned) of two different degradable polymers and a polymer intended for long term applications could influence primary articular chondrocytes growth and ultrastructure. A degradable copoly(ether) esterurethane (PDC) was synthesized via co-condensation of poly(p-dioxanone) diol and poly(epsilon-caprolactone) diol using an aliphatic diisocyanate as linker. Poly(p-dioxanone) (PPDO) was applied as commercially available degradable polymer, while polyetherimide (PEI) was chosen as biomaterial enabling surface functionalization. The fibrous scaffolds of PDC and PPDO were obtained by electrospinning using 1,1,1,3,3,3 hexafluoro-2-propanol (HFP), while for PEI dimethyl acetamide (DMAc) was applied as solvent. Primary porcine articular chondrocytes were seeded at different cell densities on the fibrous polymer scaffolds and analyzed for viability (fluorescein diacetate/ethidiumbromide staining), for type II collagen synthesis (immunolabelling), ultrastructure and orientation on the fibers (SEM: scanning electron microscopy). Vital chondrocytes adhered on all electrospun scaffolds irrespective of random and aligned topologies. In addition, the chondrocytes produced the cartilage-specific type II collagen on all tested polymer topologies suggesting their differentiated functions. SEM revealed an almost flattened chondrocytes shape on scaffolds with random fiber orientation: whereby chondrocytes growth remained mainly restricted to the scaffold surface. On aligned fibers the chondrocytes exhibited a more spindle-shaped morphology with rougher cell surfaces but only a minority of the cells aligned according to the fibers. As a next step the reduction of the fiber diameter of electrospun scaffolds should be addressed as an important parameter to mimic cartilage ECM structure. KW - Chondrocytes KW - electrospinning KW - scaffold KW - differentiation KW - multiblock copolymer Y1 - 2012 U6 - https://doi.org/10.3233/CH-2012-1608 SN - 1386-0291 VL - 52 IS - 2-4 SP - 325 EP - 336 PB - IOS Press CY - Amsterdam ER - TY - JOUR A1 - Sauter, Tilman A1 - Kratz, Karl A1 - Lendlein, Andreas T1 - Pore-size distribution controls shape-memory properties on the macro- and microscale of polymeric foams JF - Macromolecular chemistry and physics N2 - Open porous foams with identical foam density but different pore-size distributions (bimodal or monomodal) are prepared from a shape-memory polyetherurethane (PEU) by thermally induced phase separation. The shape-memory effect of the two PEU foams is explored by cyclic thermomechanical compression tests and microstructural analysis. The obtained results reveal that the PEU foam with a bimodal pore-size distribution exhibits an increased shape-recovery under stress-free conditions, both on the macro- (foam level) as well as the microscale (pore level). While bimodal pore-size distributions induce microscale bending during compression, buckling occurs in foams with monomodal pore-size distributions, leading to both a reduced and delayed shape recovery. KW - microstructure KW - morphology KW - polymer foams KW - pore-size distribution KW - shape-memory polymers Y1 - 2013 U6 - https://doi.org/10.1002/macp.201300062 SN - 1022-1352 VL - 214 IS - 11 SP - 1184 EP - 1188 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Rüder, Constantin A1 - Sauter, Tilman A1 - Kratz, Karl A1 - Haase, Tobias A1 - Peter, Jan A1 - Jung, Friedrich A1 - Lendlein, Andreas A1 - Zohlnhöfer, Dietlind T1 - Influence of fibre diameter and orientation of electrospun copolyetheresterurethanes on smooth muscle and endothelial cell behaviour JF - Clinical hemorheology and microcirculation : blood flow and vessels N2 - Polymers exhibiting cell-selective effects represent an extensive research field with high relevance for biomedical applications e.g. in the cardiovascular field supporting re-endothelialization while suppressing smooth muscle cell overgrowth. Such an endothelial cell-selective effect could be recently demonstrated for a copolyetheresterurethane (PDC) containing biodegradable poly(p-dioxanone) and poly(epsilon-caprolactone) segments, which selectively enhanced the adhesion of human umbilical vein endothelial cells (HUVEC) while suppressing the attachment of smooth muscle cells (SMC). In this study we investigated the influence of the fibre orientation (random and aligned) and fibre diameter (2 mu m and 500 nm) of electrospun PDC scaffolds on the adhesion, proliferation and apoptosis of HUVEC and SMC. Adhesion, viability and proliferation of HUVEC was diminished when the fibre diameter was reduced to a submicron scale, while the orientation of the microfibres did only slightly influence the cellular behaviour. In contrast, a submicron fibre diameter improved SMC viability. In conclusion, PDC scaffolds with micron-sized single fibres could be promising candidate materials for cell-selective stent coatings. KW - Endothelialization KW - drug eluting stent KW - degradable polymer KW - electrospinning KW - cell selectivity Y1 - 2013 U6 - https://doi.org/10.3233/CH-131787 SN - 1386-0291 SN - 1875-8622 VL - 55 IS - 4 SP - 513 EP - 522 PB - IOS Press CY - Amsterdam ER - TY - JOUR A1 - Sauter, Tilman A1 - Geiger, Brett A1 - Kratz, Karl A1 - Lendlein, Andreas T1 - Encasement of metallic cardiovascular stents with endothelial cell-selective copolyetheresterurethane microfibers JF - Polymers for advanced technologies N2 - Cardiovascular metallic stents established in clinical application are typically coated by a thin polymeric layer on the stent struts to improve hemocompatibility, whereby often a drug is added to the coating to inhibit neointimal hyperplasia. Besides such thin film coatings recently nano/microfiber coated stents are investigated, whereby the fibrous coating was applied circumferential on stents. Here, we explored whether a thin fibrous encasement of metallic stents with preferentially longitudinal aligned fibers and different local fiber densities can be achieved by electrospinning. An elastic degradable copolyetheresterurethane, which is reported to selectively enhance the adhesion of endothelial cells, while simultaneously rejecting smooth muscle cells, was utilized for stent coating. The fibrous stent encasements were microscopically assessed regarding their single fiber diameters, fiber covered area and fiber alignment at three characteristic stent regions before and after stent expansion. Stent coatings with thicknesses in the range from 30 to 50 mu m were achieved via electrospinning with 1,1,1,3,3,3-hexafluoro-2-propanol (HFP)-based polymer solution, while a mixture of HFP and formic acid as solvent resulted in encasements with a thickness below 5 mu m comprising submicron sized single fibers. All polymeric encasements were mechanically stable during expansion, whereby the fibers deposited on the struts remained their position. The observed changes in fiber density and diameter indicated diverse local deformation mechanisms of the microfibers at the different regions between the struts. Based on these results it can be anticipated that the presented fibrous encasement of stents might be a promising alternative to stents with polymeric strut coatings releasing anti-proliferative drugs. Copyright (c) 2015 John Wiley & Sons, Ltd. KW - multifunctional polymers KW - stent coatings KW - electrospinning KW - biomaterials KW - degradable polymers Y1 - 2015 U6 - https://doi.org/10.1002/pat.3583 SN - 1042-7147 SN - 1099-1581 VL - 26 IS - 10 SP - 1209 EP - 1216 PB - Wiley-Blackwell CY - Hoboken ER - TY - JOUR A1 - Li, Zhengdong A1 - Xu, Xun A1 - Wang, Weiwei A1 - Kratz, Karl A1 - Sun, Xianlei A1 - Zou, Jie A1 - Deng, Zijun A1 - Jung, Friedrich Wilhelm A1 - Gossen, Manfred A1 - Ma, Nan A1 - Lendlein, Andreas T1 - Modulation of the mesenchymal stem cell migration capacity via preconditioning with topographic microstructure JF - Clinical hemorheology and microcirculation : blood flow and vessels N2 - Controlling mesenchymal stem cells (MSCs) behavior is necessary to fully exploit their therapeutic potential. Various approaches are employed to effectively influence the migration capacity of MSCs. Here, topographic microstructures with different microscale roughness were created on polystyrene (PS) culture vessel surfaces as a feasible physical preconditioning strategy to modulate MSC migration. By analyzing trajectories of cells migrating after reseeding, we demonstrated that the mobilization velocity of human adipose derived mesenchymal stem cells (hADSCs) could be promoted by and persisted after brief preconditioning with the appropriate microtopography. Moreover, the elevated activation levels of focal adhesion kinase (FAK) and mitogen-activated protein kinase (MAPK) in hADSCs were also observed during and after the preconditioning process. These findings underline the potential enhancement of in vivo therapeutic efficacy in regenerative medicine via transplantation of topographic microstructure preconditioned stem cells. KW - Mesenchymal stem cells KW - precondition KW - microstructure KW - migration KW - FAK-MAPK Y1 - 2017 U6 - https://doi.org/10.3233/CH-179208 SN - 1386-0291 SN - 1875-8622 VL - 67 SP - 267 EP - 278 PB - IOS Press CY - Amsterdam ER - TY - JOUR A1 - Bhuvanesh, Thanga A1 - Saretia, Shivam A1 - Roch, Toralf A1 - Schöne, Anne-Christin A1 - Rottke, Falko O. A1 - Kratz, Karl A1 - Wang, Weiwei A1 - Ma, Nan A1 - Schulz, Burkhard A1 - Lendlein, Andreas T1 - Langmuir-Schaefer films of fibronectin as designed biointerfaces for culturing stem cells JF - Polymers for advanced technologies N2 - Glycoproteins adsorbing on an implant upon contact with body fluids can affect the biological response in vitro and in vivo, depending on the type and conformation of the adsorbed biomacromolecules. However, this process is poorly characterized and so far not controllable. Here, protein monolayers of high molecular cohesion with defined density are transferred onto polymeric substrates by the Langmuir-Schaefer (LS) technique and were compared with solution deposition (SO) method. It is hypothesized that on polydimethylsiloxane (PDMS), a substrate with poor cell adhesion capacity, the fibronectin (FN) layers generated by the LS and SO methods will differ in their organization, subsequently facilitating differential stem cell adhesion behavior. Indeed, atomic force microscopy visualization and immunofluorescence images indicated that organization of the FN layer immobilized on PDMS was uniform and homogeneous. In contrast, FN deposited by SO method was rather heterogeneous with appearance of structures resembling protein aggregates. Human mesenchymal stem cells showed reduced absolute numbers of adherent cells, and the vinculin expression seemed to be higher and more homogenously distributed after seeding on PDMS equipped with FN by LS in comparison with PDMS equipped with FN by SO. These divergent responses could be attributed to differences in the availability of adhesion molecule ligands such as the Arg-Gly-Asp (RGD) peptide sequence presented at the interface. The LS method allows to control the protein layer characteristics, including the thickness and the protein orientation or conformation, which can be harnessed to direct stem cell responses to defined outcomes, including migration and differentiation. Copyright (c) 2016 John Wiley & Sons, Ltd. KW - Langmuir-Schaefer method KW - protein adsorption KW - stem cell adhesion KW - cell culture KW - fibronectin Y1 - 2017 U6 - https://doi.org/10.1002/pat.3910 SN - 1042-7147 SN - 1099-1581 VL - 28 SP - 1305 EP - 1311 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Haase, Tobias A1 - Krost, Annalena A1 - Sauter, Tilman A1 - Kratz, Karl A1 - Peter, Jan A1 - Kamann, Stefanie A1 - Jung, Friedrich A1 - Lendlein, Andreas A1 - Zohlnhöfer, Dietlind A1 - Rüder, Constantin T1 - In vivo biocompatibility assessment of poly (ether imide) electrospun scaffolds JF - Journal of Tissue Engineering and Regenerative Medicine N2 - Poly(ether imide) (PEI), which can be chemically functionalized with biologically active ligands, has emerged as a potential biomaterial for medical implants. Electrospun PEI scaffolds have shown advantageous properties, such as enhanced endothelial cell adherence, proliferation and low platelet adhesion in in vitro experiments. In this study, the in vivo behaviour of electrospun PEI scaffolds and PEI films was examined in a murine subcutaneous implantation model. Electrospun PEI scaffolds and films were surgically implanted subcutaneously in the dorsae of mice. The surrounding subcutaneous tissue response was examined via histopathological examination at 7 and 28days after implantation. No serious adverse events were observed for both types of PEI implants. The presence of macrophages or foreign body giant cells in the vicinity of the implants and the formation of a fibrous capsule indicated a normal foreign body reaction towards PEI films and scaffolds. Capsule thickness and inflammatory infiltration cells significantly decreased for PEI scaffolds during days 7-28 while remaining unchanged for PEI films. The infiltration of cells into the implant was observed for PEI scaffolds 7days after implantation and remained stable until 28days of implantation. Additionally some, but not all, PEI scaffold implants induced the formation of functional blood vessels in the vicinity of the implants. Conclusively, this study demonstrates the in vivo biocompatibility of PEI implants, with favourable properties of electrospun PEI scaffolds regarding tissue integration and wound healing. KW - poly(ether imide) KW - in vivo study KW - electrospun scaffold KW - capsule formation KW - foreign body giant cells KW - vascularization Y1 - 2017 U6 - https://doi.org/10.1002/term.2002 SN - 1932-6254 SN - 1932-7005 VL - 11 IS - 4 SP - 1034 EP - 1044 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Heuchel, Matthias A1 - Gerber, David A1 - Kratz, Karl A1 - Lendlein, Andreas T1 - Morphological analysis of differently sized highly porous poly(ether imide) microparticles by mercury porosimetry JF - Polymers for advanced technologies N2 - Highly porous poly(ether imide) (PEI) microparticles prepared by a spraying/coagulation process are discussed as candidate adsorber materials for apheresis applications, i.e. removal of uremic toxins from the blood of renal failure patients. PEI particles obtained by the aforementioned procedure can have a broad size distribution with particle diameters ranging from 20 to 800 mu m. In order to further estimate the adsorption behavior of PEI microparticles packed in application relevant apheresis modules, a quantitative information about the relation between particle size and pore morphology is required. In this study, we explored whether the intraparticle porosity of PEI microparticles varies with altering the diameter of the particulate adsorbers. By an analytical wet sieving procedure, the obtained PEI microparticles were separated into five size fractions, which were analyzed by mercury intrusion porosimetry, nitrogen adsorption, and scanning electron microscopy. Mercury intrusion porosimetry revealed for all size fractions high porosity values in the range from 78% to 84% with pore diameters in the range from 10 to 1000nm. A bimodal pore size distribution was found having a first peak at around 100nm, while a second pronounced peak maximum was found at higher pore sizes that increased with raising particle diameter from 300nm for the smallest particle size fraction (50-100 mu m) to 700nm for particles with a diameter of 200 to 250 mu m. Based on these findings, it can be assumed that the main PEI particle size fraction (200-250 mu m) should exhibit the highest adsorption capacity in an apheresis module. Copyright (c) 2016 John Wiley & Sons, Ltd. KW - porous microparticles KW - poly(ether imide) KW - mercury intrusion porosimetry KW - adsorber materials Y1 - 2017 U6 - https://doi.org/10.1002/pat.3973 SN - 1042-7147 SN - 1099-1581 VL - 28 SP - 1269 EP - 1277 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Blocki, Anna A1 - Löwenberg, Candy A1 - Jiang, Yi A1 - Kratz, Karl A1 - Neffe, Axel T. A1 - Jung, Friedrich A1 - Lendlein, Andreas T1 - Response of encapsulated cells to a gelatin matrix with varied bulk and microenvironmental elastic properties JF - Polymers for advanced technologies N2 - Gelatin-based hydrogels offer various biochemical cues that support encapsulated cells and are therefore suitable as cell delivery vehicles in regenerative medicine. However, besides the biochemical signals, biomechanical cues are crucial to ensure an optimal support of encapsulated cells. Hence, we aimed to correlate the cellular response of encapsulated cells to macroscopic and microscopic elastic properties of glycidylmethacrylate (GMA)-functionalized gelatin-based hydrogels. To ensure that different observations in cellular behavior could be attributed to differences in elastic properties, an identical concentration as well as degree of functionalization of biopolymers was utilized to form covalently crosslinked hydrogels. Elastic properties were merely altered by varying the average gelatin-chain length. Hydrogels exhibited an increased degree of swelling and a decreased bulk elastic modulus G with prolonged autoclaving of the starting solution. This was accompanied by an increase of hydrogel mesh size and thus by a reduction of crosslinking density. Tougher hydrogels retained the largest amount of cells; however, they also interfered with cell viability. Softer gels contained a lower cell density, but supported cell elongation and viability. Observed differences could be partially attributed to differences in bulk properties, as high crosslinking densities interfere with diffusion and cell spreading and thus can impede cell viability. Interestingly, a microscopic elastic modulus in the range of native soft tissue supported cell viability and elongation best while ensuring a good cell entrapment. In conclusion, gelatin-based hydrogels providing a soft tissue-like microenvironment represent adequate cell delivery vehicles for tissue engineering approaches. Copyright (c) 2016 John Wiley & Sons, Ltd. KW - mechanotransduction KW - hydrogel KW - gelatin KW - cell encapsulation KW - matrix elasticity Y1 - 2017 U6 - https://doi.org/10.1002/pat.3947 SN - 1042-7147 SN - 1099-1581 VL - 28 SP - 1245 EP - 1251 PB - Wiley CY - Hoboken ER -