TY - GEN A1 - Dech, Silas A1 - Bittmann, Frank A1 - Schaefer, Laura T1 - Behavior of oxygen saturation and blood filling in the venous capillary system of the biceps brachii muscle during a fatiguing isometric action T2 - Postprints der Universität Potsdam : Humanwissenschaftliche Reihe 618 N2 - The objective of the study is to develop a better understanding of the capillary circulation in contracting muscles. Ten subjects were measured during a submaximal fatiguing isometric muscle action by use of the O2C spectrophotometer. In all measurements the capillary-venous oxygen saturation of hemoglobin (SvO2) decreases immediately after the start of loading and levels off into a steady state. However, two different patterns (type I and type II) emerged. They differ in the extent of deoxygenation (–10.37 ±2.59 percent points (pp) vs. –33.86 ±17.35 pp, P = .008) and the behavior of the relative hemoglobin amount (rHb). Type I reveals a positive rank correlation of SvO2 and rHb (? = 0.735, P <.001), whereas a negative rank correlation (? = –0.522, P <.001) occurred in type II, since rHb decreases until a reversal point, then increases averagely 13% above the baseline value and levels off into a steady state. The results reveal that a homeostasis of oxygen delivery and consumption during isometric muscle actions is possible. A rough distinction in two types of regulation is suggested. T3 - Zweitveröffentlichungen der Universität Potsdam : Humanwissenschaftliche Reihe - 618 KW - muscle oxygenation KW - hemoglobin amount KW - isometric muscle action KW - O2C spectrophotometer Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-460166 SN - 1866-8364 IS - 618 SP - 79 EP - 87 ER - TY - GEN A1 - Bittmann, Frank A1 - Dech, Silas A1 - Aehle, Markus A1 - Schaefer, Laura T1 - Manual Muscle Testing—Force Profiles and Their Reproducibility T2 - Postprints der Universität Potsdam : Humanwissenschaftliche Reihe N2 - The manual muscle test (MMT) is a flexible diagnostic tool, which is used in many disciplines, applied in several ways. The main problem is the subjectivity of the test. The MMT in the version of a “break test” depends on the tester’s force rise and the patient’s ability to resist the applied force. As a first step, the investigation of the reproducibility of the testers’ force profile is required for valid application. The study examined the force profiles of n = 29 testers (n = 9 experiences (Exp), n = 8 little experienced (LitExp), n = 12 beginners (Beg)). The testers performed 10 MMTs according to the test of hip flexors, but against a fixed leg to exclude the patient’s reaction. A handheld device recorded the temporal course of the applied force. The results show significant differences between Exp and Beg concerning the starting force (padj = 0.029), the ratio of starting to maximum force (padj = 0.005) and the normalized mean Euclidean distances between the 10 trials (padj = 0.015). The slope is significantly higher in Exp vs. LitExp (p = 0.006) and Beg (p = 0.005). The results also indicate that experienced testers show inter-tester differences and partly even a low intra-tester reproducibility. This highlights the necessity of an objective MMT-assessment. Furthermore, an agreement on a standardized force profile is required. A suggestion for this is given. T3 - Zweitveröffentlichungen der Universität Potsdam : Humanwissenschaftliche Reihe - 671 KW - manual muscle testing KW - neuromuscular diagnostics KW - force profiles KW - reproducibility KW - adaptive force KW - handheld device Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-485612 SN - 1866-8364 IS - 671 ER - TY - JOUR A1 - Dech, Silas A1 - Bittmann, Frank A1 - Schaefer, Laura T1 - Behavior of oxygen saturation and blood filling in the venous capillary system of the biceps brachii muscle during a fatiguing isometric action JF - European Journal of Translational Myology N2 - The objective of the study is to develop a better understanding of the capillary circulation in contracting muscles. Ten subjects were measured during a submaximal fatiguing isometric muscle action by use of the O2C spectrophotometer. In all measurements the capillary-venous oxygen saturation of hemoglobin (SvO2) decreases immediately after the start of loading and levels off into a steady state. However, two different patterns (type I and type II) emerged. They differ in the extent of deoxygenation (–10.37 ±2.59 percent points (pp) vs. –33.86 ±17.35 pp, P = .008) and the behavior of the relative hemoglobin amount (rHb). Type I reveals a positive rank correlation of SvO2 and rHb (? = 0.735, P <.001), whereas a negative rank correlation (? = –0.522, P <.001) occurred in type II, since rHb decreases until a reversal point, then increases averagely 13% above the baseline value and levels off into a steady state. The results reveal that a homeostasis of oxygen delivery and consumption during isometric muscle actions is possible. A rough distinction in two types of regulation is suggested. KW - muscle oxygenation KW - hemoglobin amount KW - isometric muscle action KW - O2C spectrophotometer Y1 - 2020 U6 - https://doi.org/10.4081/ejtm.2019.8800 SN - 2037-7460 VL - 30 IS - 1 SP - 79 EP - 87 PB - Unipress CY - Padova ER - TY - JOUR A1 - Bittmann, Frank A1 - Dech, Silas A1 - Aehle, Markus A1 - Schaefer, Laura T1 - Manual Muscle Testing—Force Profiles and Their Reproducibility JF - Diagnostics N2 - The manual muscle test (MMT) is a flexible diagnostic tool, which is used in many disciplines, applied in several ways. The main problem is the subjectivity of the test. The MMT in the version of a “break test” depends on the tester’s force rise and the patient’s ability to resist the applied force. As a first step, the investigation of the reproducibility of the testers’ force profile is required for valid application. The study examined the force profiles of n = 29 testers (n = 9 experiences (Exp), n = 8 little experienced (LitExp), n = 12 beginners (Beg)). The testers performed 10 MMTs according to the test of hip flexors, but against a fixed leg to exclude the patient’s reaction. A handheld device recorded the temporal course of the applied force. The results show significant differences between Exp and Beg concerning the starting force (padj = 0.029), the ratio of starting to maximum force (padj = 0.005) and the normalized mean Euclidean distances between the 10 trials (padj = 0.015). The slope is significantly higher in Exp vs. LitExp (p = 0.006) and Beg (p = 0.005). The results also indicate that experienced testers show inter-tester differences and partly even a low intra-tester reproducibility. This highlights the necessity of an objective MMT-assessment. Furthermore, an agreement on a standardized force profile is required. A suggestion for this is given. KW - manual muscle testing KW - neuromuscular diagnostics KW - force profiles KW - reproducibility KW - adaptive force KW - handheld device Y1 - 2020 U6 - https://doi.org/10.3390/diagnostics10120996 SN - 2075-4418 VL - 10 IS - 12 PB - MDPI CY - Basel ER -