TY - JOUR A1 - Andrews, Nicholas L. P. A1 - Ross, Rachel A1 - Munzke, Dorit A1 - van Hoorn, Camiel A1 - Brzezinski, Andrew A1 - Barnes, Jack A. A1 - Reich, Oliver A1 - Loock, Hans-Peter T1 - In-fiber Mach-Zehnder interferometer for gas refractive index measurements based on a hollow-core photonic crystal fiber JF - Optics express : the international electronic journal of optics N2 - We describe an in-fiber interferometer based on a gas-filled hollow-core photonic crystal fiber. Expressions for the sensitivity, figure of merit and refractive index resolution are derived, and values are experimentally measured and theoretically validated using mode field calculations. The refractive indices of nine monoatomic and molecular gases are measured with a resolution of delta(ns) < 10(-6). (C)2016 Optical Society of America Y1 - 2016 U6 - https://doi.org/10.1364/OE.24.014086 SN - 1094-4087 VL - 24 SP - 14086 EP - 14099 PB - Optical Society of America CY - Washington ER - TY - JOUR A1 - Andrews, N. L. P. A1 - Ferguson, T. A1 - Rangaswamy, A. M. M. A1 - Bernicky, A. R. A1 - Henning, N. A1 - Dudelzak, A. A1 - Reich, Oliver A1 - Barnes, Jack A. A1 - Loock, Hans-Peter T1 - Hadamard-Transform Fluorescence Excitation-Emission-Matrix Spectroscopy JF - Analytical chemistry N2 - We present a fluorescence excitation-emission-matrix spectrometer with superior data acquisition rates over previous instruments. Light from a white light emitting diode (LED) source is dispersed onto a digital micromirror array (DMA) and encoded using binary n-size Walsh functions ("barcodes"). The encoded excitation light is used to irradiate the liquid sample and its fluorescence is dispersed and detected using a conventional array spectrometer. After exposure to excitation light encoded in n different ways, the 2-dimensional excitation-emission-matrix (EEM) spectrum is obtained by inverse Hadamard transformation. Using this technique we examined the kinetics of the fluorescence of rhodamine B as a function of temperature and the acid-driven demetalation of chlorophyll into pheophytin-a. For these experiments, EEM spectra with 31 excitation channels and 2048 emission channels were recorded every 15 s. In total, data from over 3000 EEM spectra were included in this report. It is shown that the increase in data acquisition rate can be as high as [{n(n + 1)}/2]-fold over conventional EEM spectrometers. Spectral acquisition rates of more than two spectra per second were demonstrated. Y1 - 2017 U6 - https://doi.org/10.1021/acs.analchem.7b02400 SN - 0003-2700 SN - 1520-6882 VL - 89 SP - 8554 EP - 8564 PB - American Chemical Society CY - Washington ER -