TY - JOUR A1 - Magkos, Sotirios A1 - Kupsch, Andreas A1 - Bruno, Giovanni T1 - Suppression of cone-beam artefacts with Direct Iterative Reconstruction Computed Tomography Trajectories (DIRECTT) JF - Journal of imaging : open access journal N2 - The reconstruction of cone-beam computed tomography data using filtered back-projection algorithms unavoidably results in severe artefacts. We describe how the Direct Iterative Reconstruction of Computed Tomography Trajectories (DIRECTT) algorithm can be combined with a model of the artefacts for the reconstruction of such data. The implementation of DIRECTT results in reconstructed volumes of superior quality compared to the conventional algorithms. KW - iteration method KW - signal processing KW - X-ray imaging KW - computed tomography Y1 - 2021 U6 - https://doi.org/10.3390/jimaging7080147 SN - 2313-433X VL - 7 IS - 8 PB - MDPI CY - Basel ER -