Dokument-ID Dokumenttyp Verfasser/Autoren Herausgeber Haupttitel Abstract Auflage Verlagsort Verlag Erscheinungsjahr Seitenzahl Schriftenreihe Titel Schriftenreihe Bandzahl ISBN Quelle der Hochschulschrift Konferenzname Quelle:Titel Quelle:Jahrgang Quelle:Heftnummer Quelle:Erste Seite Quelle:Letzte Seite URN DOI Abteilungen OPUS4-51910 Wissenschaftlicher Artikel Schaefer, Laura V.; Bittmann, Frank N. Paired personal interaction reveals objective differences between pushing and holding isometric muscle action In sports and movement sciences isometric muscle function is usually measured by pushing against a stable resistance. However, subjectively one can hold or push isometrically. Several investigations suggest a distinction of those forms. The aim of this study was to investigate whether these two forms of isometric muscle action can be distinguished by objective parameters in an interpersonal setting. 20 subjects were grouped in 10 same sex pairs, in which one partner should perform the pushing isometric muscle action (PIMA) and the other partner executed the holding isometric muscle action (HIMA). The partners had contact at the distal forearms via an interface, which included a strain gauge and an acceleration sensor. The mechanical oscillations of the triceps brachii (MMGtri) muscle, its tendon (MTGtri) and the abdominal muscle (MMGobl) were recorded by a piezoelectric-sensor-based measurement system. Each partner performed three 15s (80% MVIC) and two fatiguing trials (90% MVIC) during PIMA and HIMA, respectively. Parameters to compare PIMA and HIMA were the mean frequency, the normalized mean amplitude, the amplitude variation, the power in the frequency range of 8 to 15 Hz, a special power-frequency ratio and the number of task failures during HIMA or PIMA (partner who quit the task). A "HIMA failure" occurred in 85% of trials (p < 0.001). No significant differences between PIMA and HIMA were found for the mean frequency and normalized amplitude. The MMGobl showed significantly higher values of amplitude variation (15s: p = 0.013; fatiguing: p = 0.007) and of power-frequency-ratio (15s: p = 0.040; fatiguing: p = 0.002) during HIMA and a higher power in the range of 8 to 15 Hz during PIMA (15s: p = 0.001; fatiguing: p = 0.011). MMGtri and MTGtri showed no significant differences. Based on the findings it is suggested that a holding and a pushing isometric muscle action can be distinguished objectively, whereby a more complex neural control is assumed for HIMA. San Francisco PLOS 2021 21 PLOS One 16 5 10.1371/journal.pone.0238331 Department Sport- und Gesundheitswissenschaften OPUS4-51094 Wissenschaftlicher Artikel Dech, Silas; Bittmann, Frank; Schaefer, Laura V. Assessment of the adaptive force of Elbow extensors in healthy subjects quantified by a novel pneumatically driven measurement system with considerations of its quality criteria Adaptive Force (AF) reflects the capability of the neuromuscular system to adapt adequately to external forces with the intention of maintaining a position or motion. One specific approach to assessing AF is to measure force and limb position during a pneumatically applied increasing external force. Through this method, the highest (AFmax), the maximal isometric (AFisomax) and the maximal eccentric Adaptive Force (AFeccmax) can be determined. The main question of the study was whether the AFisomax is a specific and independent parameter of muscle function compared to other maximal forces. In 13 healthy subjects (9 male and 4 female), the maximal voluntary isometric contraction (pre- and post-MVIC), the three AF parameters and the MVIC with a prior concentric contraction (MVICpri-con) of the elbow extensors were measured 4 times on two days. Arithmetic mean (M) and maximal (Max) torques of all force types were analyzed. Regarding the reliability of the AF parameters between days, the mean changes were 0.31-1.98 Nm (0.61%-5.47%, p = 0.175-0.552), the standard errors of measurements (SEM) were 1.29-5.68 Nm (2.53%-15.70%) and the ICCs(3,1) = 0.896-0.996. M and Max of AFisomax, AFmax and pre-MVIC correlated highly (r = 0.85-0.98). The M and Max of AFisomax were significantly lower (6.12-14.93 Nm; p ≤ 0.001-0.009) and more variable between trials (coefficient of variation (CVs) ≥ 21.95%) compared to those of pre-MVIC and AFmax (CVs ≤ 5.4%). The results suggest the novel measuring procedure is suitable to reliably quantify the AF, whereby the presented measurement errors should be taken into consideration. The AFisomax seems to reflect its own strength capacity and should be detected separately. It is suggested its normalization to the MVIC or AFmax could serve as an indicator of a neuromuscular function. Basel MDPI 2021 23 Diagnostics : open access journal 11 6 10.3390/diagnostics11060923 Department Sport- und Gesundheitswissenschaften OPUS4-58202 Wissenschaftlicher Artikel Schaefer, Laura V.; Dech, Silas; Wolff, Lara L.; Bittmannn, Frank N. Emotional Imagery Influences the Adaptive Force in Young Women The link between emotions and motor function has been known for decades but is still not clarified. The Adaptive Force (AF) describes the neuromuscular capability to adapt to increasing forces and was suggested to be especially vulnerable to interfering inputs. This study investigated the influence of pleasant an unpleasant food imagery on the manually assessed AF of elbow and hip flexors objectified by a handheld device in 12 healthy women. The maximal isometric AF was significantly reduced during unpleasant vs. pleasant imagery and baseline (p < 0.001, dz = 0.98-1.61). During unpleasant imagery, muscle lengthening started at 59.00 ± 22.50% of maximal AF, in contrast to baseline and pleasant imagery, during which the isometric position could be maintained mostly during the entire force increase up to ~97.90 ± 5.00% of maximal AF. Healthy participants showed an immediately impaired holding function triggered by unpleasant imagery, presumably related to negative emotions. Hence, AF seems to be suitable to test instantaneously the effect of emotions on motor function. Since musculoskeletal complaints can result from muscular instability, the findings provide insights into the understanding of the causal chain of linked musculoskeletal pain and mental stress. A case example (current stress vs. positive imagery) suggests that the approach presented in this study might have future implications for psychomotor diagnostics and therapeutics. Basel, Schweiz MDPI 2022 23 Brain Sciences 12 10 10.3390/brainsci12101318 Department Sport- und Gesundheitswissenschaften OPUS4-56686 Wissenschaftlicher Artikel Dech, Silas; Bittmann, Frank N.; Schaefer, Laura V. Muscle oxygenation and time to task failure of submaximal holding and pulling isometric muscle actions and influence of intermittent voluntary muscle twitches Background Isometric muscle actions can be performed either by initiating the action, e.g., pulling on an immovable resistance (PIMA), or by reacting to an external load, e.g., holding a weight (HIMA). In the present study, it was mainly examined if these modalities could be differentiated by oxygenation variables as well as by time to task failure (TTF). Furthermore, it was analyzed if variables are changed by intermittent voluntary muscle twitches during weight holding (Twitch). It was assumed that twitches during a weight holding task change the character of the isometric muscle action from reacting (≙ HIMA) to acting (≙ PIMA). Methods Twelve subjects (two drop outs) randomly performed two tasks (HIMA vs. PIMA or HIMA vs. Twitch, n = 5 each) with the elbow flexors at 60% of maximal torque maintained until muscle failure with each arm. Local capillary venous oxygen saturation (SvO2) and relative hemoglobin amount (rHb) were measured by light spectrometry. Results Within subjects, no significant differences were found between tasks regarding the behavior of SvO2 and rHb, the slope and extent of deoxygenation (max. SvO2 decrease), SvO2 level at global rHb minimum, and time to SvO2 steady states. The TTF was significantly longer during Twitch and PIMA (incl. Twitch) compared to HIMA (p = 0.043 and 0.047, respectively). There was no substantial correlation between TTF and maximal deoxygenation independently of the task (r = − 0.13). Conclusions HIMA and PIMA seem to have a similar microvascular oxygen and blood supply. The supply might be sufficient, which is expressed by homeostatic steady states of SvO2 in all trials and increases in rHb in most of the trials. Intermittent voluntary muscle twitches might not serve as a further support but extend the TTF. A changed neuromuscular control is discussed as possible explanation. London Springer Nature 2022 10 BMC Sports Science, Medicine and Rehabilitation 55 1 10 10.1186/s13102-022-00447-9 Strukturbereich Kognitionswissenschaften OPUS4-56017 Wissenschaftlicher Artikel Schaefer, Laura V.; Löffler, Nils; Klein, Julia; Bittmann, Frank Mechanomyography and acceleration show interlimb asymmetries in Parkinson patients without tremor compared to controls during a unilateral motor task The mechanical muscular oscillations are rarely the objective of investigations regarding the identification of a biomarker for Parkinson's disease (PD). Therefore, the aim of this study was to investigate whether or not this specific motor output differs between PD patients and controls. The novelty is that patients without tremor are investigated performing a unilateral isometric motor task. The force of armflexors and the forearm acceleration (ACC) were recorded as well as the mechanomyography of the biceps brachii (MMGbi), brachioradialis (MMGbra) and pectoralis major (MMGpect) muscles using a piezoelectric-sensor-based system during a unilateral motor task at 70% of the MVIC. The frequency, a power-frequency-ratio, the amplitude variation, the slope of amplitudes and their interlimb asymmetries were analysed. The results indicate that the oscillatory behavior of muscular output in PD without tremor deviates from controls in some parameters: Significant differences appeared for the power-frequency-ratio (p=0.001, r=0.43) and for the amplitude variation (p=0.003, r=0.34) of MMGpect. The interlimb asymmetries differed significantly concerning the power-frequency-ratio of MMGbi (p=0.013, r=0.42) and MMGbra (p=0.048, r=0.39) as well as regarding the mean frequency (p=0.004, r=0.48) and amplitude variation of MMGpect (p=0.033, r=0.37). The mean (M) and variation coefficient (CV) of slope of ACC differed significantly (M: p=0.022, r=0.33; CV: p=0.004, r=0.43). All other parameters showed no significant differences between PD and controls. It remains open, if this altered mechanical muscular output is reproducible and specific for PD. London Macmillan 2021 15 Scientific reports 11 1 10.1038/s41598-021-81672-z Department Sport- und Gesundheitswissenschaften OPUS4-43917 Wissenschaftlicher Artikel Schaefer, Laura V.; Bittmann, Frank N. Muscular Pre-Activation Can Boost the Maximal Explosive Eccentric Adaptive Force The improvement of power is an objective in training of athletes. In order to detect effective methods of exercise, basic research is required regarding the mechanisms of muscular activity. The purpose of this study is to investigate whether or not a muscular pre-activation prior to an external impulse-like force impact has an effect on the maximal explosive eccentric Adaptive Force (xpAFeccmax). This power capability combines different probable power enhancing mechanisms. To measure the xpAFeccmax an innovative pneumatic device was used. During measuring, the subject tries to hold an isometric position as long as possible. In the moment in which the subjects' maximal isometric holding strength is exceeded, it merges into eccentric muscle action. This process is very close to motions in sports, where an adaptation of the neuromuscular system is required, e.g., force impacts caused by uneven surfaces during skiing. For investigating the effect of pre-activation on the xpAFeccmax of the quadriceps femoris muscle, n = 20 subjects had to pass three different pre-activation levels in a randomized order (level 1: 0.4 bar, level 2: 0.8 bar, level 3: 1.2 bar). After adjusting the standardized pre-pressure by pushing against the interface, an impulse-like load impacted on the distal tibia of the subject. During this, the xpAFeccmax was detected. The maximal voluntary isometric contraction (MVIC) was also measured. The torque values of the xpAFeccmax were compared with regard to the pre-activation levels. The results show a significant positive relation between the pre-activation of the quadriceps femoris muscle and the xpAFeccmax (male: p = 0.000, η2= 0.683; female: p = 0.000, η2= 0.907). The average percentage increase of torque amounted +28.15 ± 25.4% between MVIC and xpAFeccmax with pre-pressure level 1, +12.09 ± 7.9% for the xpAFeccmax comparing pre-pressure levels 1 vs. 2 and +2.98 ± 4.2% comparing levels 2 and 3. A higher but not maximal muscular activation prior to a fast impacting eccentric load seems to produce an immediate increase of force outcome. Different possible physiological explanatory approaches and the use as a potential training method are discussed. Lausanne Frontiers Research Foundation 2019 12 Frontiers in Physiology 10 10.3389/fphys.2019.00910 Strukturbereich Kognitionswissenschaften OPUS4-52303 Wissenschaftlicher Artikel Schaefer, Laura V.; Löffler, Nils; Klein, Julia; Bittmann, Frank N. Mechanomyography and acceleration show interlimb asymmetries in Parkinson patients without tremor compared to controls during a unilateral motor task The mechanical muscular oscillations are rarely the objective of investigations regarding the identification of a biomarker for Parkinson's disease (PD). Therefore, the aim of this study was to investigate whether or not this specific motor output differs between PD patients and controls. The novelty is that patients without tremor are investigated performing a unilateral isometric motor task. The force of armflexors and the forearm acceleration (ACC) were recorded as well as the mechanomyography of the biceps brachii (MMGbi), brachioradialis (MMGbra) and pectoralis major (MMGpect) muscles using a piezoelectric-sensor-based system during a unilateral motor task at 70% of the MVIC. The frequency, a power-frequency-ratio, the amplitude variation, the slope of amplitudes and their interlimb asymmetries were analysed. The results indicate that the oscillatory behavior of muscular output in PD without tremor deviates from controls in some parameters: Significant differences appeared for the power-frequency-ratio (p = 0.001, r = 0.43) and for the amplitude variation (p = 0.003, r = 0.34) of MMGpect. The interlimb asymmetries differed significantly concerning the power-frequency-ratio of MMGbi (p = 0.013, r = 0.42) and MMGbra (p = 0.048, r = 0.39) as well as regarding the mean frequency (p = 0.004, r = 0.48) and amplitude variation of MMGpect (p = 0.033, r = 0.37). The mean (M) and variation coefficient (CV) of slope of ACC differed significantly (M: p = 0.022, r = 0.33; CV: p = 0.004, r = 0.43). All other parameters showed no significant differences between PD and controls. It remains open, if this altered mechanical muscular output is reproducible and specific for PD. Berlin Springer Nature 2021 15 Scientific Reports 11 10.1038/s41598-021-81672-z Department Sport- und Gesundheitswissenschaften OPUS4-44542 Wissenschaftlicher Artikel Schaefer, Laura V.; Bittmann, Frank N. Parkinson patients without tremor show changed patterns of mechanical muscle oscillations during a specific bilateral motor task compared to controls The pathophysiology of Parkinson's disease (PD) is still not understood. There are investigations which show a changed oscillatory behaviour of brain circuits or changes in variability of, e.g., gait parameters in PD. The aim of this study was to investigate whether or not the motor output differs between PD patients and healthy controls. Thereby, patients without tremor are investigated in the medication off state performing a special bilateral isometric motor task. The force and accelerations (ACC) were recorded as well as the Mechanomyography (MMG) of the biceps brachii, the brachioradialis and of the pectoralis major muscles using piezoelectric-sensors during the bilateral motor task at 60% of the maximal isometric contraction. The frequency, a specific power ratio, the amplitude variation and the slope of amplitudes were analysed. The results indicate that the oscillatory behaviour of motor output in PD patients without tremor deviates from controls: thereby, the 95%-confidence-intervals of power ratio and of amplitude variation of all signals are disjoint between PD and controls and show significant differences in group comparisons (power ratio: p = 0.000-0.004, r = 0.441-0.579; amplitude variation: p = 0.000-0.001, r = 0.37-0.67). The mean frequency shows a significant difference for ACC (p = 0.009, r = 0.43), but not for MMG. It remains open, whether this muscular output reflects changes of brain circuits and whether the results are reproducible and specific for PD. London Macmillan Publishers Limited, part of Springer Nature 2020 16 Scientific Reports 10 10.1038/s41598-020-57766-5 Strukturbereich Kognitionswissenschaften OPUS4-52406 Wissenschaftlicher Artikel Dech, Silas; Bittmann, Frank N.; Schaefer, Laura V. Muscle oxygenation level might trigger the regulation of capillary venous blood filling during fatiguing isometric muscle actions The regulation of oxygen and blood supply during isometric muscle actions is still unclear. Recently, two behavioral types of oxygen saturation (SvO2) and relative hemoglobin amount (rHb) in venous microvessels were described during a fatiguing holding isometric muscle action (HIMA) (type I: nearly parallel behavior of SvO2 and rHb; type II: partly inverse behavior). The study aimed to ascertain an explanation of these two regulative behaviors. Twelve subjects performed one fatiguing HIMA trial with each arm by weight holding at 60% of the maximal voluntary isometric contraction (MVIC) in a 90° elbow flexion. Six subjects additionally executed one fatiguing PIMA trial by pulling on an immovable resistance with 60% of the MVIC with each side and same position. Both regulative types mentioned were found during HIMA (I: n = 7, II: n = 17) and PIMA (I: n = 3, II: n = 9). During the fatiguing measurements, rHb decreased initially and started to increase in type II at an average SvO2-level of 58.75 ± 2.14%. In type I, SvO2 never reached that specific value during loading. This might indicate the existence of a threshold around 59% which seems to trigger the increase in rHb and could explain the two behavioral types. An approach is discussed to meet the apparent incompatibility of an increased capillary blood filling (rHb) despite high intramuscular pressures which were found by other research groups during isometric muscle actions. Basel MDPI 2021 17 Diagnostics 11 11 Department Psychologie OPUS4-54897 Wissenschaftlicher Artikel Schaefer, Laura V.; Dech, Silas; Aehle, Markus; Bittmann, Frank Disgusting odours affect the characteristics of the adaptive force in contrast to neutral and pleasant odours The olfactomotor system is especially investigated by examining the sniffing in reaction to olfactory stimuli. The motor output of respiratory-independent muscles was seldomly considered regarding possible influences of smells. The Adaptive Force (AF) characterizes the capability of the neuromuscular system to adapt to external forces in a holding manner and was suggested to be more vulnerable to possible interfering stimuli due to the underlying complex control processes. The aim of this pilot study was to measure the effects of olfactory inputs on the AF of the hip and elbow flexors, respectively. The AF of 10 subjects was examined manually by experienced testers while smelling at sniffing sticks with neutral, pleasant or disgusting odours. The reaction force and the limb position were recorded by a handheld device. The results show, inter alia, a significantly lower maximal isometric AF and a significantly higher AF at the onset of oscillations by perceiving disgusting odours compared to pleasant or neutral odours (p < 0.001). The adaptive holding capacity seems to reflect the functionality of the neuromuscular control, which can be impaired by disgusting olfactory inputs. An undisturbed functioning neuromuscular system appears to be characterized by a proper length tension control and by an earlier onset of mutual oscillations during an external force increase. This highlights the strong connection of olfaction and motor control also regarding respiratory-independent muscles. London Springer Nature 2021 16 Scientific Reports 11 1 16 10.1038/s41598-021-95759-0 Extern OPUS4-46657 Wissenschaftlicher Artikel Schaefer, Laura V.; Bittmann, Frank N. Are there two forms of isometric muscle action? Results of the experimental study support a distinction between a holding and a pushing isometric muscle function Background: In isometric muscle function, there are subjectively two different modes of performance: one can either hold isometrically - thus resist an impacting force - or push isometrically -therefore work against a stable resistance. The purpose of this study is to investigate whether or not two different isometric muscle actions - the holding vs. pushing one (HIMA vs PIMA) - can be distinguished by objective parameters. Methods: Ten subjects performed two different measuring modes at 80% of MVC realized by a special pneumatic system. During HIMA the subject had to resist the defined impacting force of the pneumatic system in an isometric position, whereby the force of the cylinder works in direction of elbow flexion against the subject. During PIMA the subject worked isometrically in direction of elbow extension against a stable position of the system. The signals of pressure, force, acceleration and mechanomyography/-tendography (MMG/MTG) of the elbow extensor (MMGtri/MTGtri) and the abdominal muscle (MMGobl) were recorded and evaluated concerning the duration of maintaining the force level (force endurance) and the characteristics of MMG-/MTG-signals. Statistical group differences comparing HIMA vs. PIMA were estimated using SPSS. Results: Significant differences between HIMA and PIMA were especially apparent regarding the force endurance: During HIMA the subjects showed a decisively shorter time of stable isometric position (19 +/- 8 s) in comparison with PIMA (41 +/- 24 s; p = .005). In addition, during PIMA the longest isometric plateau amounted to 59.4% of the overall duration time of isometric measuring, during HIMA it lasted 31.6% (p = .000). The frequency of MMG/MTG did not show significant differences. The power in the frequency ranges of 8-15 Hz and 10-29 Hz was significantly higher in the MTGtri performing HIMA compared to PIMA (but not for the MMGs). The amplitude of MMG/MTG did not show any significant difference considering the whole measurement. However, looking only at the last 10% of duration time (exhaustion), the MMGtri showed significantly higher amplitudes during PIMA. Conclusion: The results suggest that under holding isometric conditions muscles exhaust earlier. That means that there are probably two forms of isometric muscle action. We hypothesize two potential reasons for faster yielding during HIMA: (1) earlier metabolic fatigue of the muscle fibers and (2) the complexity of neural control strategies. London BioMed Central 2017 13 BMC sports science, medicine & rehabilitation 9 10.1186/s13102-017-0075-z Department Sport- und Gesundheitswissenschaften OPUS4-7001 Dissertation Schaefer, Laura V. Synchronisationsphänomene myotendinöser Oszillationen interagierender neuromuskulärer Systeme Muskeln oszillieren nachgewiesener Weise mit einer Frequenz um 10 Hz. Doch was geschieht mit myofaszialen Oszillationen, wenn zwei neuromuskuläre Systeme interagieren? Die Dissertation widmet sich dieser Fragestellung bei isometrischer Interaktion. Während der Testmessungen ergaben sich Hinweise für das Vorhandensein von möglicherweise zwei verschiedenen Formen der Isometrie. Arbeiten zwei Personen isometrisch gegeneinander, können subjektiv zwei Modi eingenommen werden: man kann entweder isometrisch halten - der Kraft des Partners widerstehen - oder isometrisch drücken - gegen den isometrischen Widerstand des Partners arbeiten. Daher wurde zusätzlich zu den Messungen zur Interaktion zweier Personen an einzelnen Individuen geprüft, ob möglicherweise zwei Formen der Isometrie existieren. Die Promotion besteht demnach aus zwei inhaltlich und methodisch getrennten Teilen: I „Single-Isometrie" und II „Paar-Isometrie". Für Teil I wurden mithilfe eines pneumatisch betriebenen Systems die hypothetischen Messmodi Halten und Drücken während isometrischer Aktion untersucht. Bei n = 10 Probanden erfolgte parallel zur Aufzeichnung des Drucksignals während der Messungen die Erfassung der Kraft (DMS) und der Beschleunigung sowie die Aufnahme der mechanischen Muskeloszillationen folgender myotendinöser Strukturen via Mechanomyo- (MMG) bzw. Mechanotendografie (MTG): M. triceps brachii (MMGtri), Trizepssehne (MTGtri), M. obliquus externus abdominis (MMGobl). Pro Proband wurden bei 80 % der MVC sowohl sechs 15-Sekunden-Messungen (jeweils drei im haltenden bzw. drückenden Modus; Pause: 1 Minute) als auch vier Ermüdungsmessungen (jeweils zwei im haltenden bzw. drückenden Modus; Pause: 2 Minuten) durchgeführt. Zum Vergleich der Messmodi Halten und Drücken wurden die Amplituden der myofaszialen Oszillationen sowie die Kraftausdauer herangezogen. Signifikante Unterschiede zwischen dem haltenden und dem drückenden Modus zeigten sich insbesondere im Bereich der Ermüdungscharakteristik. So lassen Probanden im haltenden Modus signifikant früher nach als im drückenden Modus (t(9) = 3,716; p = .005). Im drückenden Modus macht das längste isometrische Plateau durchschnittlich 59,4 % der Gesamtdauer aus, im haltenden sind es 31,6 % (t(19) = 5,265, p = .000). Die Amplituden der Single-Isometrie-Messungen unterscheiden sich nicht signifikant. Allerdings variieren die Amplituden des MMGobl zwischen den Messungen im drückenden Modus signifikant stärker als im haltenden Modus. Aufgrund dieser teils signifikanten Unterschiede zwischen den beiden Messmodi wurde dieses Setting auch im zweiten Teil „Paar-Isometrie" berücksichtigt. Dort wurden n = 20 Probanden - eingeteilt in zehn gleichgeschlechtliche Paare - während isometrischer Interaktion untersucht. Die Sensorplatzierung erfolgte analog zu Teil I. Die Oszillationen der erfassten MTG- sowie MMG-Signale wurden u.a. mit Algorithmen der Nichtlinearen Dynamik auf ihre Kohärenz hin untersucht. Durch die Paar-Isometrie-Messungen zeigte sich, dass die Muskeln und die Sehnen beider neuromuskulärer Systeme bei Interaktion im bekannten Frequenzbereich von 10 Hz oszillieren. Außerdem waren sie in der Lage, sich bei Interaktion so aufeinander abzustimmen, dass sich eine signifikante Kohärenz entwickelte, die sich von Zufallspaarungen signifikant unterscheidet (Patchanzahl: t(29) = 3,477; p = .002; Summe der 4 längsten Patches: t(29) = 7,505; p = .000). Es wird der Schluss gezogen, dass neuromuskuläre Komplementärpartner in der Lage sind, sich im Sinne kohärenten Verhaltens zu synchronisieren. Bezüglich der Parameter zur Untersuchung der möglicherweise vorhandenen zwei Formen der Isometrie zeigte sich bei den Paar-Isometrie-Messungen zwischen Halten und Drücken ein signifikanter Unterschied bei der Ermüdungscharakteristik sowie bezüglich der Amplitude der MMGobl. Die Ergebnisse beider Teilstudien bestärken die Hypothese, dass zwei Formen der Isometrie existieren. Fraglich ist, ob man überhaupt von Isometrie sprechen kann, da jede isometrische Muskelaktion aus feinen Oszillationen besteht, die eine per Definition postulierte Isometrie ausschließen. Es wird der Vorschlag unterbreitet, die Isometrie durch den Begriff der Homöometrie auszutauschen. Die Ergebnisse der Paar-Isometrie-Messungen zeigen u.a., dass neuromuskuläre Systeme in der Lage sind, ihre myotendinösen Oszillationen so aufeinander abzustimmen, dass kohärentes Verhalten entsteht. Es wird angenommen, dass hierzu beide neuromuskulären Systeme funktionell intakt sein müssen. Das Verfahren könnte für die Diagnostik funktioneller Störungen relevant werden. 2014 urn:nbn:de:kobv:517-opus-72445 Department Sport- und Gesundheitswissenschaften OPUS4-46016 misc Dech, Silas; Bittmann, Frank N.; Schaefer, Laura V. Behavior of oxygen saturation and blood filling in the venous capillary system of the biceps brachii muscle during a fatiguing isometric action The objective of the study is to develop a better understanding of the capillary circulation in contracting muscles. Ten subjects were measured during a submaximal fatiguing isometric muscle action by use of the O2C spectrophotometer. In all measurements the capillary-venous oxygen saturation of hemoglobin (SvO2) decreases immediately after the start of loading and levels off into a steady state. However, two different patterns (type I and type II) emerged. They differ in the extent of deoxygenation (-10.37 ±2.59 percent points (pp) vs. -33.86 ±17.35 pp, P = .008) and the behavior of the relative hemoglobin amount (rHb). Type I reveals a positive rank correlation of SvO2 and rHb (? = 0.735, P <.001), whereas a negative rank correlation (? = -0.522, P <.001) occurred in type II, since rHb decreases until a reversal point, then increases averagely 13% above the baseline value and levels off into a steady state. The results reveal that a homeostasis of oxygen delivery and consumption during isometric muscle actions is possible. A rough distinction in two types of regulation is suggested. 2020 11 Postprints der Universität Potsdam : Humanwissenschaftliche Reihe 618 618 79 87 urn:nbn:de:kobv:517-opus4-460166 10.25932/publishup-46016 Humanwissenschaftliche Fakultät OPUS4-44543 misc Schaefer, Laura V.; Bittmann, Frank N. Parkinson patients without tremor show changed patterns of mechanical muscle oscillations during a specific bilateral motor task compared to controls The pathophysiology of Parkinson's disease (PD) is still not understood. There are investigations which show a changed oscillatory behaviour of brain circuits or changes in variability of, e.g., gait parameters in PD. The aim of this study was to investigate whether or not the motor output differs between PD patients and healthy controls. Thereby, patients without tremor are investigated in the medication off state performing a special bilateral isometric motor task. The force and accelerations (ACC) were recorded as well as the Mechanomyography (MMG) of the biceps brachii, the brachioradialis and of the pectoralis major muscles using piezoelectric-sensors during the bilateral motor task at 60% of the maximal isometric contraction. The frequency, a specific power ratio, the amplitude variation and the slope of amplitudes were analysed. The results indicate that the oscillatory behaviour of motor output in PD patients without tremor deviates from controls: thereby, the 95%-confidence-intervals of power ratio and of amplitude variation of all signals are disjoint between PD and controls and show significant differences in group comparisons (power ratio: p = 0.000-0.004, r = 0.441-0.579; amplitude variation: p = 0.000-0.001, r = 0.37-0.67). The mean frequency shows a significant difference for ACC (p = 0.009, r = 0.43), but not for MMG. It remains open, whether this muscular output reflects changes of brain circuits and whether the results are reproducible and specific for PD. 2020 18 Postprints der Universität Potsdam : Humanwissenschaftliche Reihe 602 urn:nbn:de:kobv:517-opus4-445431 10.25932/publishup-44543 Strukturbereich Kognitionswissenschaften OPUS4-48348 Wissenschaftlicher Artikel Schaefer, Laura V.; Bittmann, Frank Mechanotendography in Achillodynia shows reduced oscillation variability of pre-loaded Achilles tendon The present study focuses on an innovative approach in measuring the mechanical oscillations of pre-loaded Achilles tendon by using Mechanotendography (MTG) during application of a short yet powerful mechanical pressure impact. This was applied on the forefoot from the plantar side in direction of dorsiflexion, while the subject stood on the ball of the forefoot on one leg. Participants with Achilles tendinopathy (AT; n = 10) were compared to healthy controls (Con; n = 10). Five trials were performed on each side of the body. For evaluation, two intervals after the impulse began (0-100ms; 30-100ms) were cut from the MTG and pressure raw signals. The intrapersonal variability between the five trials in both intervals were evaluated using the arithmetic mean and coefficient of variation of the mean correlation (Spearman rank correlation) and the normalized averaged mean distances, respectively. The AT-group showed a significantly reduced variability in MTG compared to the Con-group (from p = 0.006 to p = 0.028 for different parameters). The 95% confidence intervals (CI) of MTG results were disjoint, whereas the 95% CIs of the pressure signals were similar (p = 0.192 to p = 0.601). We suggest from this work that the variability of mechanical tendon oscillations could be an indicative parameter of an altered Achilles tendon functionality. Padova Unipress 2020 10 European Journal of Translational Myology (EJTM) 30 2 247 257 10.4081/ejtm.2020.8983 Strukturbereich Kognitionswissenschaften OPUS4-46015 Wissenschaftlicher Artikel Dech, Silas; Bittmann, Frank N.; Schaefer, Laura V. Behavior of oxygen saturation and blood filling in the venous capillary system of the biceps brachii muscle during a fatiguing isometric action The objective of the study is to develop a better understanding of the capillary circulation in contracting muscles. Ten subjects were measured during a submaximal fatiguing isometric muscle action by use of the O2C spectrophotometer. In all measurements the capillary-venous oxygen saturation of hemoglobin (SvO2) decreases immediately after the start of loading and levels off into a steady state. However, two different patterns (type I and type II) emerged. They differ in the extent of deoxygenation (-10.37 ±2.59 percent points (pp) vs. -33.86 ±17.35 pp, P = .008) and the behavior of the relative hemoglobin amount (rHb). Type I reveals a positive rank correlation of SvO2 and rHb (? = 0.735, P <.001), whereas a negative rank correlation (? = -0.522, P <.001) occurred in type II, since rHb decreases until a reversal point, then increases averagely 13% above the baseline value and levels off into a steady state. The results reveal that a homeostasis of oxygen delivery and consumption during isometric muscle actions is possible. A rough distinction in two types of regulation is suggested. Padova Unipress 2020 9 European Journal of Translational Myology 30 1 79 87 10.4081/ejtm.2019.8800 Humanwissenschaftliche Fakultät OPUS4-56136 Habilitation Schaefer, Laura V. Oszillation und Adaptation als Mechanismen neuromuskulärer Steuer- und Regelprozesse 2021 Department Sport- und Gesundheitswissenschaften OPUS4-53649 Wissenschaftlicher Artikel Schaefer, Laura V.; Bittmann, Frank N. Mechanotendography The mechanotendography (MTG) is a method for analyzing the mechanical oscillations of tendons during muscular actions. The aim of this investigation was to evaluate the technical reliability of a piezo-based measurement system used for MTG. The reliability measurements were performed by using audio samples played by a subwoofer. The thereby generated pressure waves were recorded by a piezo-based measurement system. An audio of 40 Hz sine oscillations and four different formerly in vivo recorded MTG-signals were converted into audio files and were used as test signals. Five trials with each audio were performed and one audio was used for repetition trials on another day. The signals' correlation was estimated by Spearman (MCC) and intraclass correlation coefficients (ICC(3,1)), Cronbach's alpha (CA) and by mean distances (MD). All parameters were compared between repetition and randomized matched signals. The repetition trials show high correlations (MCC: 0.86 ± 0.13, ICC: 0.89 ± 0.12, CA: 0.98 ± 0.03), low MD (0.03 ± 0.03V) and differ significantly from the randomized matched signals (MCC: 0.15 ± 0.10, ICC: 0.17 ± 0.09, CA: 0.37 ± 0.16, MD: 0.19 ± 0.01V) (p = 0.001 - 0.043). This speaks for an excellent reliability of the measurement system. Presuming the skin above superficial tendons oscillates adequately, we estimate this tool as valid for the application in musculoskeletal system. Padova, Italien Unipress 2021 10 European journal of translational myology : European journal ; basic applied myology ; BAM online ; myology reviews 31 10.4081/ejtm.2021.9553 Department Sport- und Gesundheitswissenschaften OPUS4-56193 Wissenschaftlicher Artikel Schaefer, Laura V.; Bittmann, Frank N. Case Study: Intra- and Interpersonal Coherence of Muscle and Brain Activity of Two Coupled Persons during Pushing and Holding Isometric Muscle Action Inter-brain synchronization is primarily investigated during social interactions but had not been examined during coupled muscle action between two persons until now. It was previously shown that mechanical muscle oscillations can develop coherent behavior between two isometrically interacting persons. This case study investigated if inter-brain synchronization appears thereby, and if differences of inter- and intrapersonal muscle and brain coherence exist regarding two different types of isometric muscle action. Electroencephalography (EEG) and mechanomyography/mechanotendography (MMG/MTG) of right elbow extensors were recorded during six fatiguing trials of two coupled isometrically interacting participants (70% MVIC). One partner performed holding and one pushing isometric muscle action (HIMA/PIMA; tasks changed). The wavelet coherence of all signals (EEG, MMG/MTG, force, ACC) were analyzed intra- and interpersonally. The five longest coherence patches in 8-15 Hz and their weighted frequency were compared between real vs. random pairs and between HIMA vs. PIMA. Real vs. random pairs showed significantly higher coherence for intra-muscle, intra-brain, and inter-muscle-brain activity (p < 0.001 to 0.019). Inter-brain coherence was significantly higher for real vs. random pairs for EEG of right and central areas and for sub-regions of EEG left (p = 0.002 to 0.025). Interpersonal muscle-brain synchronization was significantly higher than intrapersonal one, whereby it was significantly higher for HIMA vs. PIMA. These preliminary findings indicate that inter-brain synchronization can arise during muscular interaction. It is hypothesized both partners merge into one oscillating neuromuscular system. The results reinforce the hypothesis that HIMA is characterized by more complex control strategies than PIMA. The pilot study suggests investigating the topic further to verify these results on a larger sample size. Findings could contribute to the basic understanding of motor control and is relevant for functional diagnostics such as the manual muscle test which is applied in several disciplines, e.g., neurology, physiotherapy. 6 Basel, Schweiz MDPI Open Access Publishing 2022 27 Brain Sciences 12 10.3390/brainsci12060703 Department Sport- und Gesundheitswissenschaften OPUS4-43918 misc Schaefer, Laura V.; Bittmann, Frank N. Muscular Pre-Activation Can Boost the Maximal Explosive Eccentric Adaptive Force The improvement of power is an objective in training of athletes. In order to detect effective methods of exercise, basic research is required regarding the mechanisms of muscular activity. The purpose of this study is to investigate whether or not a muscular pre-activation prior to an external impulse-like force impact has an effect on the maximal explosive eccentric Adaptive Force (xpAFeccmax). This power capability combines different probable power enhancing mechanisms. To measure the xpAFeccmax an innovative pneumatic device was used. During measuring, the subject tries to hold an isometric position as long as possible. In the moment in which the subjects' maximal isometric holding strength is exceeded, it merges into eccentric muscle action. This process is very close to motions in sports, where an adaptation of the neuromuscular system is required, e.g., force impacts caused by uneven surfaces during skiing. For investigating the effect of pre-activation on the xpAFeccmax of the quadriceps femoris muscle, n = 20 subjects had to pass three different pre-activation levels in a randomized order (level 1: 0.4 bar, level 2: 0.8 bar, level 3: 1.2 bar). After adjusting the standardized pre-pressure by pushing against the interface, an impulse-like load impacted on the distal tibia of the subject. During this, the xpAFeccmax was detected. The maximal voluntary isometric contraction (MVIC) was also measured. The torque values of the xpAFeccmax were compared with regard to the pre-activation levels. The results show a significant positive relation between the pre-activation of the quadriceps femoris muscle and the xpAFeccmax (male: p = 0.000, η2= 0.683; female: p = 0.000, η2= 0.907). The average percentage increase of torque amounted +28.15 ± 25.4% between MVIC and xpAFeccmax with pre-pressure level 1, +12.09 ± 7.9% for the xpAFeccmax comparing pre-pressure levels 1 vs. 2 and +2.98 ± 4.2% comparing levels 2 and 3. A higher but not maximal muscular activation prior to a fast impacting eccentric load seems to produce an immediate increase of force outcome. Different possible physiological explanatory approaches and the use as a potential training method are discussed. 2018 14 Postprints der Universität Potsdam Humanwissenschaftliche Reihe 582 urn:nbn:de:kobv:517-opus4-439189 10.25932/publishup-43918 Strukturbereich Kognitionswissenschaften