@article{MichalikOnichimowskaKernRiedeletal.2017, author = {Michalik-Onichimowska, Aleksandra and Kern, Simon and Riedel, Jens and Panne, Ulrich and King, Rudibert and Maiwald, Michael}, title = {"Click" analytics for "click" chemistry - A simple method for calibration-free evaluation of online NMR spectra}, series = {Journal of magnetic resonance}, volume = {277}, journal = {Journal of magnetic resonance}, publisher = {Elsevier}, address = {San Diego}, issn = {1090-7807}, doi = {10.1016/j.jmr.2017.02.018}, pages = {154 -- 161}, year = {2017}, abstract = {Driven mostly by the search for chemical syntheses under biocompatible conditions, so called "click" chemistry rapidly became a growing field of research. The resulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via comparably straightforward and robust analysis techniques possessing short set-up times. Here, we report on a fast and reliable calibration-free online NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement of H-1 spectra with a time interval of 20 s per spectrum, and a robust, fully automated algorithm to interpret the obtained data. As a proof-of-concept, the thiol-ene coupling between N-boc cysteine methyl ester and ally] alcohol was conducted in a variety of non-deuterated solvents while its time-resolved behaviour was characterized with step tracer experiments. Overlapping signals in online spectra during thiol-ene coupling could be deconvoluted with a spectral model using indirect hard modeling and were subsequently converted to either molar ratios (using a calibration free approach) or absolute concentrations (using 1-point calibration). For various solvents the kinetic constant k for pseudo-first order reaction was estimated to be 3.9 h(-1) at 25 degrees C. The obtained results were compared with direct integration of non-overlapping signals and showed good agreement with the implemented mass balance. (C) 2017 Elsevier Inc. All rights reserved.}, language = {en} } @article{MitznerRehanekKernetal.2013, author = {Mitzner, Rolf and Rehanek, Jens and Kern, Jan and Gul, Sheraz and Hattne, Johan and Taguchi, Taketo and Alonso-Mori, Roberto and Tran, Rosalie and Weniger, Christian and Schr{\"o}der, Henning and Quevedo, Wilson and Laksmono, Hartawan and Sierra, Raymond G. and Han, Guangye and Lassalle-Kaiser, Benedikt and Koroidov, Sergey and Kubicek, Katharina and Schreck, Simon and Kunnus, Kristjan and Brzhezinskaya, Maria and Firsov, Alexander and Minitti, Michael P. and Turner, Joshua J. and M{\"o}ller, Stefan and Sauter, Nicholas K. and Bogan, Michael J. and Nordlund, Dennis and Schlotter, William F. and Messinger, Johannes and Borovik, Andrew S. and Techert, Simone and de Groot, Frank M. F. and F{\"o}hlisch, Alexander and Erko, Alexei and Bergmann, Uwe and Yachandra, Vittal K. and Wernet, Philippe and Yano, Junko}, title = {L-edge x-ray absorption spectroscopy of dilute systems relevant to metalloproteins using an X-ray free-electron laser}, series = {The journal of physical chemistry letters}, volume = {4}, journal = {The journal of physical chemistry letters}, number = {21}, publisher = {American Chemical Society}, address = {Washington}, issn = {1948-7185}, doi = {10.1021/jz401837f}, pages = {3641 -- 3647}, year = {2013}, abstract = {L-edge spectroscopy of 3d transition metals provides important electronic structure information and has been used in many fields. However, the use of this method for studying dilute aqueous systems, such as metalloenzymes, has not been prevalent because of severe radiation damage and the lack of suitable detection systems. Here we present spectra from a dilute Mn aqueous solution using a high-transmission zone-plate spectrometer at the Linac Coherent Light Source (LCLS). The spectrometer has been optimized for discriminating the Mn L-edge signal from the overwhelming 0 K-edge background that arises from water and protein itself, and the ultrashort LCLS X-ray pulses can outrun X-ray induced damage. We show that the deviations of the partial-fluorescence yield-detected spectra from the true absorption can be well modeled using the state-dependence of the fluorescence yield, and discuss implications for the application of our concept to biological samples.}, language = {en} }