@article{LettauGajovicEichelmannKwaketal.2004, author = {Lettau, Kristian and Gajovic-Eichelmann, N. and Kwak, Young-Keun and Scheller, Frieder W. and Warsinke, Axel}, title = {Hydroxylasen und katalytische Polymere f{\"u}r Biochips}, year = {2004}, language = {de} } @article{SchellerTiepnerWarsinke2004, author = {Scheller, Frieder W. and Tiepner, K. and Warsinke, Axel}, title = {Anwendung von Biosensoren in der Lebensmittelanalytik}, isbn = {3-89947-120-2}, year = {2004}, language = {de} } @article{SchellerWarsinkePfeifferetal.2004, author = {Scheller, Frieder W. and Warsinke, Axel and Pfeiffer, Dorothea and Czeponik, J.}, title = {Biosensorik / Bioanalytik}, isbn = {3-87081-372-5}, year = {2004}, language = {de} } @article{LettauWarsinkeLaschewskyetal.2004, author = {Lettau, Kristian and Warsinke, Axel and Laschewsky, Andr{\´e} and Mosbach, K. and Yilmaz, E. and Scheller, Frieder W.}, title = {An esterolytic imprinted polymer prepared via a silica-supported transition state analogue}, year = {2004}, abstract = {In this work we describe a new preparation method for an esterolytic imprinted polymer with catalytic sites on the surface. A template was prepared by immobilizing a transition state analogue (phosphoramidic acid derivative) of an esterolytic reaction within porous silica particles. Polymerization within the pores was carried out using 4- vinylimidazole as a functional monomer and divinylbenzene as a cross-linker. The polymer was released by dissolution of the silica support with hydrofluoric acid and catalytic properties were studied by incubation with three different 4- nitrophenylesters and spectrophotometric determination of the released 4-nitrophenol. For 4-nitrophenyl acetate an activity of 211 nmol min(-1) mg(-1) and a K-m value of 2.2 mmol L-1 was obtained}, language = {en} } @article{PieperFuerstKleuserStoeckleinetal.2004, author = {Pieper-F{\"u}rst, U. and Kleuser, U. and St{\"o}cklein, Walter F. M. and Warsinke, Axel and Scheller, Frieder W.}, title = {Detection of subicomolar concentrations of human matrix metalloproteinase-2 by an optical biosensor}, year = {2004}, abstract = {We describe in this paper the development of a one-step sandwich assay for the highly sensitive and fast detection of human matrix metalloproteinase (MMP)-2 (EC 3.4.24.24), using surface plasmon resonance (SPR). For the assay, two ligands were selected: monoclonal anti-MMP-2 antibody Ab-2 and the tissue inhibitor of metalloproteinases (TIMP)-2. They were chosen on the basis of (1) their affinities to MMP-2, (2) the efficiency of immobilization to the sensor chip, (3) the efficiency of adsorption to colloidal gold, and (4) the stability of these protein-coated gold particles. The assay included mixing of MMP-2 with antibody Ab-2 adsorbed to colloidal gold with a diameter of about 20 rim and injection into the flowcell of the SPR instrument containing immobilized TIMP-2. By using colloidal gold particles an amplification factor of 114 and a detection limit of 0.5 pM for MMP-2 were obtained. The precision of the assay was high even at low analyte concentrations, the standard deviation being 8.3\% for five determinations of 1 pM MMP- 2. No significant binding was observed with the structurally related MMP-9. The assay is far more sensitive and faster than commonly used methods for MMP-2 detection. As TIMP-bound MMP-2 is not detected by this method, the assay can be applied for measuring free MMP-2, reflecting the imbalance of free and inhibitor-bound enzyme in various pathological situations. (C) 2004 Elsevier Inc. All rights reserved}, language = {en} }