@article{DechBittmannSchaefer2022, author = {Dech, Silas and Bittmann, Frank N. and Schaefer, Laura V.}, title = {Muscle oxygenation and time to task failure of submaximal holding and pulling isometric muscle actions and influence of intermittent voluntary muscle twitches}, series = {BMC Sports Science, Medicine and Rehabilitation}, volume = {55}, journal = {BMC Sports Science, Medicine and Rehabilitation}, publisher = {Springer Nature}, address = {London}, issn = {1758-2555}, doi = {10.1186/s13102-022-00447-9}, pages = {1 -- 10}, year = {2022}, abstract = {Background Isometric muscle actions can be performed either by initiating the action, e.g., pulling on an immovable resistance (PIMA), or by reacting to an external load, e.g., holding a weight (HIMA). In the present study, it was mainly examined if these modalities could be differentiated by oxygenation variables as well as by time to task failure (TTF). Furthermore, it was analyzed if variables are changed by intermittent voluntary muscle twitches during weight holding (Twitch). It was assumed that twitches during a weight holding task change the character of the isometric muscle action from reacting (≙ HIMA) to acting (≙ PIMA). Methods Twelve subjects (two drop outs) randomly performed two tasks (HIMA vs. PIMA or HIMA vs. Twitch, n = 5 each) with the elbow flexors at 60\% of maximal torque maintained until muscle failure with each arm. Local capillary venous oxygen saturation (SvO2) and relative hemoglobin amount (rHb) were measured by light spectrometry. Results Within subjects, no significant differences were found between tasks regarding the behavior of SvO2 and rHb, the slope and extent of deoxygenation (max. SvO2 decrease), SvO2 level at global rHb minimum, and time to SvO2 steady states. The TTF was significantly longer during Twitch and PIMA (incl. Twitch) compared to HIMA (p = 0.043 and 0.047, respectively). There was no substantial correlation between TTF and maximal deoxygenation independently of the task (r = - 0.13). Conclusions HIMA and PIMA seem to have a similar microvascular oxygen and blood supply. The supply might be sufficient, which is expressed by homeostatic steady states of SvO2 in all trials and increases in rHb in most of the trials. Intermittent voluntary muscle twitches might not serve as a further support but extend the TTF. A changed neuromuscular control is discussed as possible explanation.}, language = {en} } @misc{DechBittmannSchaefer2022, author = {Dech, Silas and Bittmann, Frank N. and Schaefer, Laura V.}, title = {Muscle oxygenation and time to task failure of submaximal holding and pulling isometric muscle actions and influence of intermittent voluntary muscle twitches}, series = {Zweitver{\"o}ffentlichungen der Universit{\"a}t Potsdam : Humanwissenschaftliche Reihe}, journal = {Zweitver{\"o}ffentlichungen der Universit{\"a}t Potsdam : Humanwissenschaftliche Reihe}, publisher = {Universit{\"a}tsverlag Potsdam}, address = {Potsdam}, issn = {1866-8364}, doi = {10.25932/publishup-56687}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus4-566878}, pages = {1 -- 10}, year = {2022}, abstract = {Background Isometric muscle actions can be performed either by initiating the action, e.g., pulling on an immovable resistance (PIMA), or by reacting to an external load, e.g., holding a weight (HIMA). In the present study, it was mainly examined if these modalities could be differentiated by oxygenation variables as well as by time to task failure (TTF). Furthermore, it was analyzed if variables are changed by intermittent voluntary muscle twitches during weight holding (Twitch). It was assumed that twitches during a weight holding task change the character of the isometric muscle action from reacting (≙ HIMA) to acting (≙ PIMA). Methods Twelve subjects (two drop outs) randomly performed two tasks (HIMA vs. PIMA or HIMA vs. Twitch, n = 5 each) with the elbow flexors at 60\% of maximal torque maintained until muscle failure with each arm. Local capillary venous oxygen saturation (SvO2) and relative hemoglobin amount (rHb) were measured by light spectrometry. Results Within subjects, no significant differences were found between tasks regarding the behavior of SvO2 and rHb, the slope and extent of deoxygenation (max. SvO2 decrease), SvO2 level at global rHb minimum, and time to SvO2 steady states. The TTF was significantly longer during Twitch and PIMA (incl. Twitch) compared to HIMA (p = 0.043 and 0.047, respectively). There was no substantial correlation between TTF and maximal deoxygenation independently of the task (r = - 0.13). Conclusions HIMA and PIMA seem to have a similar microvascular oxygen and blood supply. The supply might be sufficient, which is expressed by homeostatic steady states of SvO2 in all trials and increases in rHb in most of the trials. Intermittent voluntary muscle twitches might not serve as a further support but extend the TTF. A changed neuromuscular control is discussed as possible explanation.}, language = {en} } @misc{DechBittmannSchaefer2021, author = {Dech, Silas and Bittmann, Frank N. and Schaefer, Laura V.}, title = {Assessment of the Adaptive Force of Elbow Extensors in Healthy Subjects Quantified by a Novel Pneumatically Driven Measurement System with Considerations of Its Quality Criteria}, series = {Postprints der Universit{\"a}t Potsdam : Humanwissenschaftliche Reihe}, journal = {Postprints der Universit{\"a}t Potsdam : Humanwissenschaftliche Reihe}, number = {710}, issn = {1866-8364}, doi = {10.25932/publishup-51095}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus4-510950}, pages = {25}, year = {2021}, abstract = {Adaptive Force (AF) reflects the capability of the neuromuscular system to adapt adequately to external forces with the intention of maintaining a position or motion. One specific approach to assessing AF is to measure force and limb position during a pneumatically applied increasing external force. Through this method, the highest (AFmax), the maximal isometric (AFisomax) and the maximal eccentric Adaptive Force (AFeccmax) can be determined. The main question of the study was whether the AFisomax is a specific and independent parameter of muscle function compared to other maximal forces. In 13 healthy subjects (9 male and 4 female), the maximal voluntary isometric contraction (pre- and post-MVIC), the three AF parameters and the MVIC with a prior concentric contraction (MVICpri-con) of the elbow extensors were measured 4 times on two days. Arithmetic mean (M) and maximal (Max) torques of all force types were analyzed. Regarding the reliability of the AF parameters between days, the mean changes were 0.31-1.98 Nm (0.61\%-5.47\%, p = 0.175-0.552), the standard errors of measurements (SEM) were 1.29-5.68 Nm (2.53\%-15.70\%) and the ICCs(3,1) = 0.896-0.996. M and Max of AFisomax, AFmax and pre-MVIC correlated highly (r = 0.85-0.98). The M and Max of AFisomax were significantly lower (6.12-14.93 Nm; p ≤ 0.001-0.009) and more variable between trials (coefficient of variation (CVs) ≥ 21.95\%) compared to those of pre-MVIC and AFmax (CVs ≤ 5.4\%). The results suggest the novel measuring procedure is suitable to reliably quantify the AF, whereby the presented measurement errors should be taken into consideration. The AFisomax seems to reflect its own strength capacity and should be detected separately. It is suggested its normalization to the MVIC or AFmax could serve as an indicator of a neuromuscular function.}, language = {en} } @article{SchaeferBittmann2020, author = {Schaefer, Laura V. and Bittmann, Frank N.}, title = {Parkinson patients without tremor show changed patterns of mechanical muscle oscillations during a specific bilateral motor task compared to controls}, series = {Scientific Reports}, volume = {10}, journal = {Scientific Reports}, publisher = {Macmillan Publishers Limited, part of Springer Nature}, address = {London}, issn = {2045-2322}, doi = {10.1038/s41598-020-57766-5}, pages = {16}, year = {2020}, abstract = {The pathophysiology of Parkinson's disease (PD) is still not understood. There are investigations which show a changed oscillatory behaviour of brain circuits or changes in variability of, e.g., gait parameters in PD. The aim of this study was to investigate whether or not the motor output differs between PD patients and healthy controls. Thereby, patients without tremor are investigated in the medication off state performing a special bilateral isometric motor task. The force and accelerations (ACC) were recorded as well as the Mechanomyography (MMG) of the biceps brachii, the brachioradialis and of the pectoralis major muscles using piezoelectric-sensors during the bilateral motor task at 60\% of the maximal isometric contraction. The frequency, a specific power ratio, the amplitude variation and the slope of amplitudes were analysed. The results indicate that the oscillatory behaviour of motor output in PD patients without tremor deviates from controls: thereby, the 95\%-confidence-intervals of power ratio and of amplitude variation of all signals are disjoint between PD and controls and show significant differences in group comparisons (power ratio: p = 0.000-0.004, r = 0.441-0.579; amplitude variation: p = 0.000-0.001, r = 0.37-0.67). The mean frequency shows a significant difference for ACC (p = 0.009, r = 0.43), but not for MMG. It remains open, whether this muscular output reflects changes of brain circuits and whether the results are reproducible and specific for PD.}, language = {en} } @misc{SchaeferBittmann2020, author = {Schaefer, Laura V. and Bittmann, Frank N.}, title = {Parkinson patients without tremor show changed patterns of mechanical muscle oscillations during a specific bilateral motor task compared to controls}, series = {Postprints der Universit{\"a}t Potsdam : Humanwissenschaftliche Reihe}, journal = {Postprints der Universit{\"a}t Potsdam : Humanwissenschaftliche Reihe}, number = {602}, issn = {1866-8364}, doi = {10.25932/publishup-44543}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus4-445431}, pages = {18}, year = {2020}, abstract = {The pathophysiology of Parkinson's disease (PD) is still not understood. There are investigations which show a changed oscillatory behaviour of brain circuits or changes in variability of, e.g., gait parameters in PD. The aim of this study was to investigate whether or not the motor output differs between PD patients and healthy controls. Thereby, patients without tremor are investigated in the medication off state performing a special bilateral isometric motor task. The force and accelerations (ACC) were recorded as well as the Mechanomyography (MMG) of the biceps brachii, the brachioradialis and of the pectoralis major muscles using piezoelectric-sensors during the bilateral motor task at 60\% of the maximal isometric contraction. The frequency, a specific power ratio, the amplitude variation and the slope of amplitudes were analysed. The results indicate that the oscillatory behaviour of motor output in PD patients without tremor deviates from controls: thereby, the 95\%-confidence-intervals of power ratio and of amplitude variation of all signals are disjoint between PD and controls and show significant differences in group comparisons (power ratio: p = 0.000-0.004, r = 0.441-0.579; amplitude variation: p = 0.000-0.001, r = 0.37-0.67). The mean frequency shows a significant difference for ACC (p = 0.009, r = 0.43), but not for MMG. It remains open, whether this muscular output reflects changes of brain circuits and whether the results are reproducible and specific for PD.}, language = {en} } @article{SchaeferBittmann2020, author = {Schaefer, Laura V. and Bittmann, Frank}, title = {Mechanotendography in Achillodynia shows reduced oscillation variability of pre-loaded Achilles tendon}, series = {European Journal of Translational Myology (EJTM)}, volume = {30}, journal = {European Journal of Translational Myology (EJTM)}, number = {2}, publisher = {Unipress}, address = {Padova}, issn = {2037-7460}, doi = {10.4081/ejtm.2020.8983}, pages = {247 -- 257}, year = {2020}, abstract = {The present study focuses on an innovative approach in measuring the mechanical oscillations of pre-loaded Achilles tendon by using Mechanotendography (MTG) during application of a short yet powerful mechanical pressure impact. This was applied on the forefoot from the plantar side in direction of dorsiflexion, while the subject stood on the ball of the forefoot on one leg. Participants with Achilles tendinopathy (AT; n = 10) were compared to healthy controls (Con; n = 10). Five trials were performed on each side of the body. For evaluation, two intervals after the impulse began (0-100ms; 30-100ms) were cut from the MTG and pressure raw signals. The intrapersonal variability between the five trials in both intervals were evaluated using the arithmetic mean and coefficient of variation of the mean correlation (Spearman rank correlation) and the normalized averaged mean distances, respectively. The AT-group showed a significantly reduced variability in MTG compared to the Con-group (from p = 0.006 to p = 0.028 for different parameters). The 95\% confidence intervals (CI) of MTG results were disjoint, whereas the 95\% CIs of the pressure signals were similar (p = 0.192 to p = 0.601). We suggest from this work that the variability of mechanical tendon oscillations could be an indicative parameter of an altered Achilles tendon functionality.}, language = {en} } @misc{SchaeferBittmann2020, author = {Schaefer, Laura V. and Bittmann, Frank}, title = {Mechanotendography in Achillodynia shows reduced oscillation variability of pre-loaded Achilles tendon}, series = {Postprints der Universit{\"a}t Potsdam : Humanwissenschaftliche Reihe}, journal = {Postprints der Universit{\"a}t Potsdam : Humanwissenschaftliche Reihe}, number = {668}, issn = {1866-8364}, doi = {10.25932/publishup-48349}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus4-483499}, pages = {13}, year = {2020}, abstract = {The present study focuses on an innovative approach in measuring the mechanical oscillations of pre-loaded Achilles tendon by using Mechanotendography (MTG) during application of a short yet powerful mechanical pressure impact. This was applied on the forefoot from the plantar side in direction of dorsiflexion, while the subject stood on the ball of the forefoot on one leg. Participants with Achilles tendinopathy (AT; n = 10) were compared to healthy controls (Con; n = 10). Five trials were performed on each side of the body. For evaluation, two intervals after the impulse began (0-100ms; 30-100ms) were cut from the MTG and pressure raw signals. The intrapersonal variability between the five trials in both intervals were evaluated using the arithmetic mean and coefficient of variation of the mean correlation (Spearman rank correlation) and the normalized averaged mean distances, respectively. The AT-group showed a significantly reduced variability in MTG compared to the Con-group (from p = 0.006 to p = 0.028 for different parameters). The 95\% confidence intervals (CI) of MTG results were disjoint, whereas the 95\% CIs of the pressure signals were similar (p = 0.192 to p = 0.601). We suggest from this work that the variability of mechanical tendon oscillations could be an indicative parameter of an altered Achilles tendon functionality.}, language = {en} } @article{SchaeferBittmann2019, author = {Schaefer, Laura V. and Bittmann, Frank N.}, title = {Muscular Pre-Activation Can Boost the Maximal Explosive Eccentric Adaptive Force}, series = {Frontiers in Physiology}, volume = {10}, journal = {Frontiers in Physiology}, publisher = {Frontiers Research Foundation}, address = {Lausanne}, issn = {1664-042X}, doi = {10.3389/fphys.2019.00910}, pages = {12}, year = {2019}, abstract = {The improvement of power is an objective in training of athletes. In order to detect effective methods of exercise, basic research is required regarding the mechanisms of muscular activity. The purpose of this study is to investigate whether or not a muscular pre-activation prior to an external impulse-like force impact has an effect on the maximal explosive eccentric Adaptive Force (xpAFeccmax). This power capability combines different probable power enhancing mechanisms. To measure the xpAFeccmax an innovative pneumatic device was used. During measuring, the subject tries to hold an isometric position as long as possible. In the moment in which the subjects' maximal isometric holding strength is exceeded, it merges into eccentric muscle action. This process is very close to motions in sports, where an adaptation of the neuromuscular system is required, e.g., force impacts caused by uneven surfaces during skiing. For investigating the effect of pre-activation on the xpAFeccmax of the quadriceps femoris muscle, n = 20 subjects had to pass three different pre-activation levels in a randomized order (level 1: 0.4 bar, level 2: 0.8 bar, level 3: 1.2 bar). After adjusting the standardized pre-pressure by pushing against the interface, an impulse-like load impacted on the distal tibia of the subject. During this, the xpAFeccmax was detected. The maximal voluntary isometric contraction (MVIC) was also measured. The torque values of the xpAFeccmax were compared with regard to the pre-activation levels. The results show a significant positive relation between the pre-activation of the quadriceps femoris muscle and the xpAFeccmax (male: p = 0.000, η2= 0.683; female: p = 0.000, η2= 0.907). The average percentage increase of torque amounted +28.15 ± 25.4\% between MVIC and xpAFeccmax with pre-pressure level 1, +12.09 ± 7.9\% for the xpAFeccmax comparing pre-pressure levels 1 vs. 2 and +2.98 ± 4.2\% comparing levels 2 and 3. A higher but not maximal muscular activation prior to a fast impacting eccentric load seems to produce an immediate increase of force outcome. Different possible physiological explanatory approaches and the use as a potential training method are discussed.}, language = {en} } @misc{SchaeferBittmann2018, author = {Schaefer, Laura V. and Bittmann, Frank N.}, title = {Muscular Pre-Activation Can Boost the Maximal Explosive Eccentric Adaptive Force}, series = {Postprints der Universit{\"a}t Potsdam Humanwissenschaftliche Reihe}, journal = {Postprints der Universit{\"a}t Potsdam Humanwissenschaftliche Reihe}, number = {582}, issn = {1866-8364}, doi = {10.25932/publishup-43918}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus4-439189}, pages = {14}, year = {2018}, abstract = {The improvement of power is an objective in training of athletes. In order to detect effective methods of exercise, basic research is required regarding the mechanisms of muscular activity. The purpose of this study is to investigate whether or not a muscular pre-activation prior to an external impulse-like force impact has an effect on the maximal explosive eccentric Adaptive Force (xpAFeccmax). This power capability combines different probable power enhancing mechanisms. To measure the xpAFeccmax an innovative pneumatic device was used. During measuring, the subject tries to hold an isometric position as long as possible. In the moment in which the subjects' maximal isometric holding strength is exceeded, it merges into eccentric muscle action. This process is very close to motions in sports, where an adaptation of the neuromuscular system is required, e.g., force impacts caused by uneven surfaces during skiing. For investigating the effect of pre-activation on the xpAFeccmax of the quadriceps femoris muscle, n = 20 subjects had to pass three different pre-activation levels in a randomized order (level 1: 0.4 bar, level 2: 0.8 bar, level 3: 1.2 bar). After adjusting the standardized pre-pressure by pushing against the interface, an impulse-like load impacted on the distal tibia of the subject. During this, the xpAFeccmax was detected. The maximal voluntary isometric contraction (MVIC) was also measured. The torque values of the xpAFeccmax were compared with regard to the pre-activation levels. The results show a significant positive relation between the pre-activation of the quadriceps femoris muscle and the xpAFeccmax (male: p = 0.000, η2= 0.683; female: p = 0.000, η2= 0.907). The average percentage increase of torque amounted +28.15 ± 25.4\% between MVIC and xpAFeccmax with pre-pressure level 1, +12.09 ± 7.9\% for the xpAFeccmax comparing pre-pressure levels 1 vs. 2 and +2.98 ± 4.2\% comparing levels 2 and 3. A higher but not maximal muscular activation prior to a fast impacting eccentric load seems to produce an immediate increase of force outcome. Different possible physiological explanatory approaches and the use as a potential training method are discussed.}, language = {en} } @misc{SchaeferBittmann2018, author = {Schaefer, Laura V. and Bittmann, Frank N.}, title = {Coherent behavior of neuromuscular oscillations between isometrically interacting subjects}, series = {Postprints der Universit{\"a}t Potsdam : Humanwissenschaftliche Reihe}, journal = {Postprints der Universit{\"a}t Potsdam : Humanwissenschaftliche Reihe}, number = {480}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus4-419864}, pages = {10}, year = {2018}, abstract = {Previous research has shown that electrical muscle activity is able to synchronize between muscles of one subject. The ability to synchronize the mechanical muscle oscillations measured by Mechanomyography (MMG) is not described sufficiently. Likewise, the behavior of myofascial oscillations was not considered yet during muscular interaction of two human subjects. The purpose of this study is to investigate the myofascial oscillations intra- and interpersonally. For this the mechanical muscle oscillations of the triceps and the abdominal external oblique muscles were measured by MMG and the triceps tendon was measured by mechanotendography (MTG) during isometric interaction of two subjects (n = 20) performed at 80\% of the MVC using their arm extensors. The coherence of MMG/MTG-signals was analyzed with coherence wavelet transform and was compared with randomly matched signal pairs. Each signal pairing shows significant coherent behavior. Averagely, the coherent phases of n = 485 real pairings last over 82 ± 39 \% of the total duration time of the isometric interaction. Coherent phases of randomly matched signal pairs take 21 ± 12 \% of the total duration time (n = 39). The difference between real vs. randomly matched pairs is significant (U = 113.0, p = 0.000, r = 0.73). The results show that the neuromuscular system seems to be able to synchronize to another neuromuscular system during muscular interaction and generate a coherent behavior of the mechanical muscular oscillations. Potential explanatory approaches are discussed.}, language = {en} }