@article{WernetKunnusSchrecketal.2012, author = {Wernet, Philippe and Kunnus, Kristjan and Schreck, Simon and Quevedo, Wilson and Kurian, Reshmi and Techert, Simone and de Groot, Frank M. F. and Odelius, Michael and F{\"o}hlisch, Alexander}, title = {Dissecting local atomic and intermolecular interactions of transition-metal ions in solution with selective X-ray spectroscopy}, series = {The journal of physical chemistry letters}, volume = {3}, journal = {The journal of physical chemistry letters}, number = {23}, publisher = {American Chemical Society}, address = {Washington}, issn = {1948-7185}, doi = {10.1021/jz301486u}, pages = {3448 -- 3453}, year = {2012}, abstract = {Determining covalent and charge-transfer contributions to bonding in solution has remained an experimental challenge. Here, the quenching of fluorescence decay channels as expressed in dips in the L-edge X-ray spectra of solvated 3d transition-metal ions and complexes was reported as a probe. With a full set of experimental and theoretical ab initio L-edge X-ray spectra of aqueous Cr3+, including resonant inelastic X-ray scattering, we address covalency and charge transfer for this prototypical transition-metal ion in solution. We dissect local atomic effects from intermolecular interactions and quantify X-ray optical effects. We find no evidence for the asserted ultrafast charge transfer to the solvent and show that the dips are readily explained by X-ray optical effects and local atomic state dependence of the fluorescence yield. Instead, we find, besides ionic interactions, a covalent contribution to the bonding in the aqueous complex of ligand-to-metal charge-transfer character.}, language = {en} } @article{ThielemannKuehnHoffmannFoehlisch2012, author = {Thielemann-K{\"u}hn, Nele and Hoffmann, P. and F{\"o}hlisch, Alexander}, title = {A versatile detector for total fluorescence and electron yield experiments}, series = {Review of scientific instruments : a monthly journal devoted to scientific instruments, apparatus, and techniques}, volume = {83}, journal = {Review of scientific instruments : a monthly journal devoted to scientific instruments, apparatus, and techniques}, number = {9}, publisher = {American Institute of Physics}, address = {Melville}, issn = {0034-6748}, doi = {10.1063/1.4754126}, pages = {3}, year = {2012}, abstract = {The combination of a non-coated silicon photodiode with electron repelling meshes makes a versatile detector for total fluorescence yield and electron yield techniques highly suitable for x-ray absorption spectroscopy. In particular, a copper mesh with a bias voltage allows to suppress or transmit the electron yield signal. The performance of this detection scheme has been characterized by near edge x-ray absorption fine structure studies of thermal oxidized silicon and sapphire. The results show that the new detector probes both electron yield and for a bias voltage exceeding the maximum photon energy the total fluorescence yield.}, language = {en} } @article{KunnusRajkovicSchrecketal.2012, author = {Kunnus, Kristjan and Rajkovic, Ivan and Schreck, Simon and Quevedo, Wilson and Eckert, Sebastian and Beye, Martin and Suljoti, Edlira and Weniger, Christian and Kalus, Christian and Gruebel, Sebastian and Scholz, Mirko and Nordlund, Dennis and Zhang, Wenkai and Hartsock, Robert W. and Gaffney, Kelly J. and Schlotter, William F. and Turner, Joshua J. and Kennedy, Brian and Hennies, Franz and Techert, Simone and Wernet, Philippe and F{\"o}hlisch, Alexander}, title = {A setup for resonant inelastic soft x-ray scattering on liquids at free electron laser light sources}, series = {Review of scientific instruments : a monthly journal devoted to scientific instruments, apparatus, and techniques}, volume = {83}, journal = {Review of scientific instruments : a monthly journal devoted to scientific instruments, apparatus, and techniques}, number = {12}, publisher = {American Institute of Physics}, address = {Melville}, issn = {0034-6748}, doi = {10.1063/1.4772685}, pages = {8}, year = {2012}, abstract = {We present a flexible and compact experimental setup that combines an in vacuum liquid jet with an x-ray emission spectrometer to enable static and femtosecond time-resolved resonant inelastic soft x-ray scattering (RIXS) measurements from liquids at free electron laser (FEL) light sources. We demonstrate the feasibility of this type of experiments with the measurements performed at the Linac Coherent Light Source FEL facility. At the FEL we observed changes in the RIXS spectra at high peak fluences which currently sets a limit to maximum attainable count rate at FELs. The setup presented here opens up new possibilities to study the structure and dynamics in liquids.}, language = {en} }