@article{BadalyanNeumannSchaalLeimkuehleretal.2013, author = {Badalyan, Artavazd and Neumann-Schaal, Meina and Leimk{\"u}hler, Silke and Wollenberger, Ursula}, title = {A Biosensor for aromatic aldehydes comprising the mediator dependent PaoABC-Aldehyde oxidoreductase}, series = {Electroanalysis : an international journal devoted to fundamental and practical aspects of electroanalysis}, volume = {25}, journal = {Electroanalysis : an international journal devoted to fundamental and practical aspects of electroanalysis}, number = {1}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1040-0397}, doi = {10.1002/elan.201200362}, pages = {101 -- 108}, year = {2013}, abstract = {A novel aldehyde oxidoreductase (PaoABC) from Escherichia coli was utilized for the development of an oxygen insensitive biosensor for benzaldehyde. The enzyme was immobilized in polyvinyl alcohol and currents were measured for aldehyde oxidation with different one and two electron mediators with the highest sensitivity for benzaldehyde in the presence of hexacyanoferrate(III). The benzaldehyde biosensor was optimized with respect to mediator concentration, enzyme loading and pH using potassium hexacyanoferrate(III). The linear measuring range is between 0.5200 mu M benzaldehyde. In correspondence with the substrate selectivity of the enzyme in solution the biosensor revealed a preference for aromatic aldehydes and less effective conversion of aliphatic aldehydes. The biosensor is oxygen independent, which is a particularly attractive feature for application. The biosensor can be applied to detect contaminations with benzaldehyde in solvents such as benzyl alcohol, where traces of benzaldehyde in benzyl alcohol down to 0.0042?\% can be detected.}, language = {en} } @article{FrascaMilanGuietetal.2013, author = {Frasca, Stefano and Milan, Anabel Molero and Guiet, Amandine and Goebel, Caren and Perez-Caballero, Fernando and Stiba, Konstanze and Leimk{\"u}hler, Silke and Fischer, Anna and Wollenberger, Ursula}, title = {Bioelectrocatalysis at mesoporous antimony doped tin oxide electrodes-Electrochemical characterization and direct enzyme communication}, series = {ELECTROCHIMICA ACTA}, volume = {110}, journal = {ELECTROCHIMICA ACTA}, number = {2}, publisher = {PERGAMON-ELSEVIER SCIENCE LTD}, address = {OXFORD}, issn = {0013-4686}, doi = {10.1016/j.electacta.2013.03.144}, pages = {172 -- 180}, year = {2013}, abstract = {In this paper we report immobilization and bioelectrocatalysis of human sulfite oxidase (hSO) on nanostructured antimony doped tin oxide (ATO) thin film electrodes. Two types of ATO thin film electrodes were prepared via evaporation induced self-assembly of ATO nanoparticle sols. The use of a porogen results in different porosity and film thickness. Nevertheless both electrode types reveal similar quasi reversible electrochemical behavior for positive and negatively charged small mediators. Facile and durable immobilization of catalytically active enzyme in a direct electron transfer configuration was achieved without further chemical modification of the ATO surfaces. Interestingly, the binding of hSO onto the ATO surface seems to be not only of electrostatic nature, but also originates from a strong interaction between the histidine-tag of the enzyme and the supporting material. This is suggested from stable sulfite dependent bioelectrocatalytic signals at high ionic strength and imidazole desorption experiments. As such, ATO appears as a promising conductive platform for the immobilization of complex enzymes and their application in bioelectrocatalysis. (C) 2013 Elsevier Ltd. All rights reserved.}, language = {en} } @article{YarmanWollenbergerScheller2013, author = {Yarman, Aysu and Wollenberger, Ursula and Scheller, Frieder W.}, title = {Sensors based on cytochrome P450 and CYP mimicking systems}, series = {ELECTROCHIMICA ACTA}, volume = {110}, journal = {ELECTROCHIMICA ACTA}, publisher = {PERGAMON-ELSEVIER SCIENCE LTD}, address = {OXFORD}, issn = {0013-4686}, doi = {10.1016/j.electacta.2013.03.154}, pages = {63 -- 72}, year = {2013}, abstract = {Cytochrome P450 enzymes (CYPs) act on more than 90 percent of all drugs currently on the market. The catalytic cycle requires electron supply to the heme iron in the presence of oxygen. Electrochemistry allows to characterise the reaction mechanism of these redox enzymes by observing the electron transfer in real time. According to the number of publications on protein electrochemistry CYP has the third position after glucose oxidase and cytochrome c. CYP based enzyme electrodes for the quantification of drugs, metabolites or pesticides have been developed using different iso-enzymes. A crucial step in the sensor development is the efficiency of coupling the biocatalytic systems with the electrode is. In the 1970s the direct electron transfer of heme and heme peptides called microperoxidases (MPs) was used as model of oxidoreductases. They exhibit a broad substrate spectrum including hydroxylation of selected aromatic substrates, demethylation and epoxidation by means of hydrogen peroxide. It overlaps with that of P450 making heme and MPs to alternate recognition elements in biosensors for the detection of typical CYP substrates. In these enzyme electrodes the signal is generated by the conversion of all substrates thus representing in complex media an overall parameter. By combining the biocatalytic substrate conversion with selective binding to a molecularly imprinted polymer layer the specificity has been improved. Here we discuss different approaches of biosensors based on CYP, microperoxidases and catalytically active MIPs and discuss their potential as recognition elements in biosensors. The performance of these sensors and their further development are discussed. (C) 2013 Elsevier Ltd. All rights reserved.}, language = {en} } @article{XuWollenbergerQianetal.2013, author = {Xu, Xuan and Wollenberger, Ursula and Qian, Jing and Lettau, Katrin and Jung, Christiane and Liu, Songqin}, title = {Electrochemically driven biocatalysis of the oxygenase domain of neuronal nitric oxide synthase in indium tin oxide nanoparticles/polyvinyl alcohol nanocomposite}, series = {Bioelectrochemistry : an international journal devoted to electrochemical aspects of biology and biological aspects of electrochemistry ; official journal of the Bioelectrochemical Society}, volume = {94}, journal = {Bioelectrochemistry : an international journal devoted to electrochemical aspects of biology and biological aspects of electrochemistry ; official journal of the Bioelectrochemical Society}, number = {47}, publisher = {Elsevier}, address = {Lausanne}, issn = {1567-5394}, doi = {10.1016/j.bioelechem.2013.04.005}, pages = {7 -- 12}, year = {2013}, abstract = {Nitric oxide synthase (NOS) plays a critical role in a number of key physiological and pathological processes. Investigation of electron-transfer reactions in NOS would contribute to a better understanding of the nitric oxide (NO) synthesis mechanism. Herein, we describe an electrochemically driven catalytic strategy, using a nanocomposite that consisted of the oxygenase domain of neuronal NOS (D290nNOSoxy), indium tin oxide (ITO) nanopartides and polyvinyl alcohol (PVA). Fast direct electron transfer between electrodes and D290nNOSoxy was observed with the heterogeneous electron transfer rate constant (k(er)) of 154.8 +/- 0.1 s(-1) at the scan rate of 5 V s(-1). Moreover, the substrate IV-hydroxy-L-arginine (NHA) was used to prove the concept of electrochemically driven biocatalysis of D290nNOSoxy. In the presence of the oxygen cosubstrate and tetrahydrobiopterin (BH4) cofactor, the addition of NHA caused the decreases of both oxidation current at + 0.1 V and reduction current at potentials ranging from -0.149 V to -0.549 V vs Ag/AgCl. Thereafter, a series of control experiments such as in the absence of BH4 or D290nNOSoxy were performed. All the results demonstrated that D290nNOSoxy biocatalysis was successfully driven by electrodes in the presence of BH4 and oxygen. This novel bioelectronic system showed potential for further investigation of NOS and biosensor applications. (C) 2013 Elsevier B.V. All rights reserved.}, language = {en} } @article{BadalyanYogaSchwuchowetal.2013, author = {Badalyan, Artavazd and Yoga, Etienne Galemou and Schwuchow, Viola and P{\"o}ller, Sascha and Schuhmann, Wolfgang and Leimk{\"u}hler, Silke and Wollenberger, Ursula}, title = {Analysis of the interaction of the molybdenum hydroxylase PaoABC from Escherichia coli with positively and negatively charged metal complexes}, series = {Electrochemistry communications : an international journal dedicated to rapid publications in electrochemistry}, volume = {37}, journal = {Electrochemistry communications : an international journal dedicated to rapid publications in electrochemistry}, publisher = {Elsevier}, address = {New York}, issn = {1388-2481}, doi = {10.1016/j.elecom.2013.09.017}, pages = {5 -- 7}, year = {2013}, abstract = {An unusual behavior of the periplasmic aldehyde oxidoreductase (PaoABC) from Escherichia coil has been observed from electrochemical investigations of the enzyme catalyzed oxidation of aromatic aldehydes with different mediators under different conditions of ionic strength. The enzyme has similarity to other molybdoenzymes of the xanthine oxidase family, but the catalytic behavior turned out to be very different. Under steady state conditions the turnover of PaoABC is maximal at pH 4 for the negatively charged ferricyanide and at pH 9 for a positively charged osmium complex. Stopped-flow kinetic measurements of the catalytic half reaction showed that oxidation of benzaldehyde proceeds also above pH 7. Thus, benzaldehyde oxidation can proceed under acidic and basic conditions using this enzyme, a property which has not been described before for molybdenum hydroxylases. It is also suggested that the electron transfer with artificial electron acceptors and PaoABC can proceed at different protein sites and depends on the nature of the electron acceptor in addition to the ionic strength. (C) 2013 Elsevier B.V. All rights reserved.}, language = {en} }