@article{DechtriratGajovicEichelmannWojciketal.2014, author = {Dechtrirat, Decha and Gajovic-Eichelmann, Nenad and Wojcik, Felix and Hartmann, Laura and Bier, Frank Fabian and Scheller, Frieder W.}, title = {Electrochemical displacement sensor based on ferrocene boronic acid tracer and immobilized glycan for saccharide binding proteins and E. coli}, series = {Biosensors and bioelectronics : the principal international journal devoted to research, design development and application of biosensors and bioelectronics}, volume = {58}, journal = {Biosensors and bioelectronics : the principal international journal devoted to research, design development and application of biosensors and bioelectronics}, publisher = {Elsevier}, address = {Oxford}, issn = {0956-5663}, doi = {10.1016/j.bios.2014.02.028}, pages = {1 -- 8}, year = {2014}, abstract = {Pathogens such as viruses and bacteria use their envelope proteins and their adhesin lectins to recognize the glycan residues presented on the cell surface of the target tissues. This principle of recognition is used in a new electrochemical displacement sensor for the protein concanavalin A (ConA). A gold electrode was first modified with a self-assembled monolayer of a thiolated mannose/OEG conjugate and a ferrocene boroxol derivative was pre-assembled as reporter molecule onto the mannose surface. The novel tracer molecule based on a 2-hydroxymethyl phenyl boronic acid derivative binds even at neutral pH to the saccharides which could expand the application towards biological samples (i.e., urine and feces). Upon the binding of ConA, the tracer was displaced and washed away from the sensor surface leading to a decrease in the electrochemical signal. Using square wave voltammetry (SWV), the concentration of ConA in the sample solution could be determined in the dynamic concentration range established from 38 nmol L-1 to 5.76 mu mol L-1 with a reproducible detection limit of 1 mu g mL(-1) (38 nmol L-1) based on the signal-to-noise ratio (S/N=3) with fast response of 15 min. The new reporter molecule showed a reduced non-specific displacement by BSA and ribonuclease A. The sensor was also successfully transferred to the first proof of principle for the detection of Escherichia coli exhibiting a detection limit of approximately 6 x 102 cells/mL Specificity of the displacement by target protein ConA and E. coli was demonstrated since the control proteins (i.e., BSA and RNaseA) and the control E. coli strain, which lack of type 1 fimbriae, were ineffective. (C) 2014 Elsevier B.V. All rights reserved.}, language = {en} } @article{HoppeBiervonNickischRosenegk2014, author = {Hoppe, Sebastian and Bier, Frank Fabian and von Nickisch-Rosenegk, Markus}, title = {Identification of antigenic proteins of the nosocomial pathogen klebsiella pneumoniae}, series = {PLoS one}, volume = {9}, journal = {PLoS one}, number = {10}, publisher = {PLoS}, address = {San Fransisco}, issn = {1932-6203}, doi = {10.1371/journal.pone.0110703}, pages = {16}, year = {2014}, abstract = {The continuous expansion of nosocomial infections around the globe has become a precarious situation. Key challenges include mounting dissemination of multiple resistances to antibiotics, the easy transmission and the growing mortality rates of hospital-acquired bacterial diseases. Thus, new ways to rapidly detect these infections are vital. Consequently, researchers around the globe pursue innovative approaches for point-of-care devices. In many cases the specific interaction of an antigen and a corresponding antibody is pivotal. However, the knowledge about suitable antigens is lacking. The aim of this study was to identify novel antigens as specific diagnostic markers. Additionally, these proteins might be aptly used for the generation of vaccines to improve current treatment options. Hence, a cDNA-based expression library was constructed and screened via microarrays to detect novel antigens of Klebsiella pneumoniae, a prominent agent of nosocomial infections well-known for its extensive antibiotics resistance, especially by extended-spectrum beta-lactamases (ESBL). After screening 1536 clones, 14 previously unknown immunogenic proteins were identified. Subsequently, each protein was expressed in full-length and its immunodominant character examined by ELISA and microarray analyses. Consequently, six proteins were selected for epitope mapping and three thereof possessed linear epitopes. After specificity analysis, homology survey and 3d structural modelling, one epitope sequence GAVVALSTTFA of KPN_00363, an ion channel protein, was identified harboring specificity for K. pneumoniae. The remaining epitopes showed ambiguous results regarding the specificity for K. pneumoniae. The approach adopted herein has been successfully utilized to discover novel antigens of Campylobacter jejuni and Salmonella enterica antigens before. Now, we have transferred this knowledge to the key nosocomial agent, K. pneumoniae. By identifying several novel antigens and their linear epitope sites, we have paved the way for crucial future research and applications including the design of point-of-care devices, vaccine development and serological screenings for a highly relevant nosocomial pathogen.}, language = {en} } @article{HovestaedtMemczakPleineretal.2014, author = {Hovestaedt, Marc and Memczak, Henry and Pleiner, Dennis and Zhang, Xin and Rappich, Joerg and Bier, Frank Fabian and St{\"o}cklein, Walter F. M.}, title = {Characterization of a new maleimido functionalization of gold for surface plasmon resonance spectroscopy}, series = {Journal of molecular recognition : an international journal devoted to research on specific molecular recognition in chemistry, biology, biotechnology and medicine}, volume = {27}, journal = {Journal of molecular recognition : an international journal devoted to research on specific molecular recognition in chemistry, biology, biotechnology and medicine}, number = {12}, publisher = {Wiley-Blackwell}, address = {Hoboken}, issn = {0952-3499}, doi = {10.1002/jmr.2396}, pages = {707 -- 713}, year = {2014}, abstract = {Para-maleimidophenyl (p-MP) modified gold surfaces have been prepared by one-step electrochemical deposition and used in surface plasmon resonance (SPR) studies. Therefore, a FITC mimotope peptide (MP1, 12 aa), a human mucin 1 epitope peptide (MUC, 9 aa) and a protein with their specific antibodies were used as model systems. The peptides were modified with an N-terminal cysteine for covalent and directed coupling to the maleimido functionalized surface by means of Michael addition. The coupling yield of the peptide, the binding characteristics of antibody and the unspecific adsorption of the analytes were investigated. The results expand the spectrum of biosensors usable with p-MP by widely used SPR and support its potential to be versatile for several electrochemical and optical biosensors. This allows the combination of an electrochemical and optical read-out for a broad variety of biomolecular interactions on the same chip. Copyright (c) 2014 John Wiley \& Sons, Ltd.}, language = {en} } @article{KerstingRauschBieretal.2014, author = {Kersting, Sebastian and Rausch, Valentina and Bier, Frank Fabian and von Nickisch-Rosenegk, Markus}, title = {Rapid detection of Plasmodium falciparum with isothermal recombinase polymerase amplification and lateral flow analysis}, series = {Malaria journal}, volume = {13}, journal = {Malaria journal}, publisher = {BioMed Central}, address = {London}, issn = {1475-2875}, doi = {10.1186/1475-2875-13-99}, pages = {9}, year = {2014}, abstract = {Background: Nucleic acid amplification is the most sensitive and specific method to detect Plasmodium falciparum. However the polymerase chain reaction remains laboratory-based and has to be conducted by trained personnel. Furthermore, the power dependency for the thermocycling process and the costly equipment necessary for the read-out are difficult to cover in resource-limited settings. This study aims to develop and evaluate a combination of isothermal nucleic acid amplification and simple lateral flow dipstick detection of the malaria parasite for point-of-care testing. Methods: A specific fragment of the 18S rRNA gene of P. falciparum was amplified in 10 min at a constant 38 C using the isothermal recombinase polymerase amplification (RPA) method. With a unique probe system added to the reaction solution, the amplification product can be visualized on a simple lateral flow strip without further labelling. The combination of these methods was tested for sensitivity and specificity with various Plasmodium and other protozoa/bacterial strains, as well as with human DNA. Additional investigations were conducted to analyse the temperature optimum, reaction speed and robustness of this assay. Results: The lateral flow RPA (LF-RPA) assay exhibited a high sensitivity and specificity. Experiments confirmed a detection limit as low as 100 fg of genomic P. falciparum DNA, corresponding to a sensitivity of approximately four parasites per reaction. All investigated P. falciparum strains (n = 77) were positively tested while all of the total 11 non-Plasmodium samples, showed a negative test result. The enzymatic reaction can be conducted under a broad range of conditions from 30-45 degrees C with high inhibitory concentration of known PCR inhibitors. A time to result of 15 min from start of the reaction to read-out was determined. Conclusions: Combining the isothermal RPA and the lateral flow detection is an approach to improve molecular diagnostic for P. falciparum in resource-limited settings. The system requires none or only little instrumentation for the nucleic acid amplification reaction and the read-out is possible with the naked eye. Showing the same sensitivity and specificity as comparable diagnostic methods but simultaneously increasing reaction speed and dramatically reducing assay requirements, the method has potential to become a true point-of-care test for the malaria parasite.}, language = {en} } @article{KerstingRauschBieretal.2014, author = {Kersting, Sebastian and Rausch, Valentina and Bier, Frank Fabian and von Nickisch-Rosenegk, Markus}, title = {Multiplex isothermal solid-phase recombinase polymerase amplification for the specific and fast DNA-based detection of three bacterial pathogens}, series = {Microchimica acta : analytical sciences based on micro- and nanomaterials}, volume = {181}, journal = {Microchimica acta : analytical sciences based on micro- and nanomaterials}, number = {13-14}, publisher = {Springer}, address = {Wien}, issn = {0026-3672}, doi = {10.1007/s00604-014-1198-5}, pages = {1715 -- 1723}, year = {2014}, abstract = {We report on the development of an on-chip RPA (recombinase polymerase amplification) with simultaneous multiplex isothermal amplification and detection on a solid surface. The isothermal RPA was applied to amplify specific target sequences from the pathogens Neisseria gonorrhoeae, Salmonella enterica and methicillin-resistant Staphylococcus aureus (MRSA) using genomic DNA. Additionally, a positive plasmid control was established as an internal control. The four targets were amplified simultaneously in a quadruplex reaction. The amplicon is labeled during on-chip RPA by reverse oligonucleotide primers coupled to a fluorophore. Both amplification and spatially resolved signal generation take place on immobilized forward primers bount to expoxy-silanized glass surfaces in a pump-driven hybridization chamber. The combination of microarray technology and sensitive isothermal nucleic acid amplification at 38 degrees C allows for a multiparameter analysis on a rather small area. The on-chip RPA was characterized in terms of reaction time, sensitivity and inhibitory conditions. A successful enzymatic reaction is completed in < 20 min and results in detection limits of 10 colony-forming units for methicillin-resistant Staphylococcus aureus and Salmonella enterica and 100 colony-forming units for Neisseria gonorrhoeae. The results show this method to be useful with respect to point-of-care testing and to enable simplified and miniaturized nucleic acid-based diagnostics.}, language = {en} } @article{SchellerYarmanBachmannetal.2014, author = {Scheller, Frieder W. and Yarman, Aysu and Bachmann, Till and Hirsch, Thomas and Kubick, Stefan and Renneberg, Reinhard and Schumacher, Soeren and Wollenberger, Ursula and Teller, Carsten and Bier, Frank Fabian}, title = {Future of biosensors: a personal view}, series = {Advances in biochemical engineering, biotechnology}, volume = {140}, journal = {Advances in biochemical engineering, biotechnology}, editor = {Gu, MB and Kim, HS}, publisher = {Springer}, address = {Berlin}, isbn = {978-3-642-54143-8; 978-3-642-54142-1}, issn = {0724-6145}, doi = {10.1007/10_2013_251}, pages = {1 -- 28}, year = {2014}, abstract = {Biosensors representing the technological counterpart of living senses have found routine application in amperometric enzyme electrodes for decentralized blood glucose measurement, interaction analysis by surface plasmon resonance in drug development, and to some extent DNA chips for expression analysis and enzyme polymorphisms. These technologies have already reached a highly advanced level and need minor improvement at most. The dream of the "100-dollar' personal genome may come true in the next few years provided that the technological hurdles of nanopore technology or of polymerase-based single molecule sequencing can be overcome. Tailor-made recognition elements for biosensors including membrane-bound enzymes and receptors will be prepared by cell-free protein synthesis. As alternatives for biological recognition elements, molecularly imprinted polymers (MIPs) have been created. They have the potential to substitute antibodies in biosensors and biochips for the measurement of low-molecular-weight substances, proteins, viruses, and living cells. They are more stable than proteins and can be produced in large amounts by chemical synthesis. Integration of nanomaterials, especially of graphene, could lead to new miniaturized biosensors with high sensitivity and ultrafast response. In the future individual therapy will include genetic profiling of isoenzymes and polymorphic forms of drug-metabolizing enzymes especially of the cytochrome P450 family. For defining the pharmacokinetics including the clearance of a given genotype enzyme electrodes will be a useful tool. For decentralized online patient control or the integration into everyday "consumables' such as drinking water, foods, hygienic articles, clothing, or for control of air conditioners in buildings and cars and swimming pools, a new generation of "autonomous' biosensors will emerge.}, language = {en} } @article{SchmitzHertzbergLieseTerjungetal.2014, author = {Schmitz-Hertzberg, Sebastian-Tim and Liese, Rick and Terjung, Carsten and Bier, Frank Fabian}, title = {Towards a smart encapsulation system for small-sized electronic devices: a new approach}, series = {International journal of polymer science}, journal = {International journal of polymer science}, publisher = {Hindawi Publishing Corp.}, address = {New York}, issn = {1687-9422}, doi = {10.1155/2014/713603}, pages = {12}, year = {2014}, abstract = {Miniaturized analytical chip devices like biosensors nowadays provide assistance in highly diverse fields of application such as point-of-care diagnostics and industrial bioprocess engineering. However, upon contact with fluids, the sensor requires a protective shell for its electrical components that simultaneously offers controlled access for the target analytes to the measuring units. We therefore developed a capsule that comprises a permeable and a sealed compartment consisting of variable polymers such as biocompatible and biodegradable polylactic acid (PLA) for medical applications or more economical polyvinyl chloride (PVC) and polystyrene (PS) polymers for bioengineering applications. Production of the sealed capsule compartments was performed by heat pressing of polymer pellets placed in individually designable molds. Controlled permeability of the opposite compartments was achieved by inclusion of NaCl inside the polymer matrix during heat pressing, followed by its subsequent release in aqueous solution. Correlating diffusion rates through the so made permeable capsule compartments were quantified for preselected model analytes: glucose, peroxidase, and polystyrene beads of three different diameters (1.4 mu m, 4.2 mu m, and 20.0 mu m). In summary, the presented capsule system turned out to provide sufficient shelter for small-sized electronic devices and gives insight into its potential permeability for defined substances of analytical interest.}, language = {en} }