@misc{BrinkmannKoellnerMerketal.2023, author = {Brinkmann, Pia and K{\"o}llner, Nicole and Merk, Sven and Beitz, Toralf and Altenberger, Uwe and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {Comparison of handheld and echelle spectrometer to assess copper in ores by means of laser-induced breakdown spectroscopy (LIBS)}, series = {Zweitver{\"o}ffentlichungen der Universit{\"a}t Potsdam : Mathematisch-Naturwissenschaftliche Reihe}, journal = {Zweitver{\"o}ffentlichungen der Universit{\"a}t Potsdam : Mathematisch-Naturwissenschaftliche Reihe}, number = {1311}, issn = {1866-8372}, doi = {10.25932/publishup-58474}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus4-584742}, pages = {19}, year = {2023}, abstract = {Its properties make copper one of the world's most important functional metals. Numerous megatrends are increasing the demand for copper. This requires the prospection and exploration of new deposits, as well as the monitoring of copper quality in the various production steps. A promising technique to perform these tasks is Laser Induced Breakdown Spectroscopy (LIBS). Its unique feature, among others, is the ability to measure on site without sample collection and preparation. In this work, copper-bearing minerals from two different deposits are studied. The first set of field samples come from a volcanogenic massive sulfide (VMS) deposit, the second part from a stratiform sedimentary copper (SSC) deposit. Different approaches are used to analyze the data. First, univariate regression (UVR) is used. However, due to the strong influence of matrix effects, this is not suitable for the quantitative analysis of copper grades. Second, the multivariate method of partial least squares regression (PLSR) is used, which is more suitable for quantification. In addition, the effects of the surrounding matrices on the LIBS data are characterized by principal component analysis (PCA), alternative regression methods to PLSR are tested and the PLSR calibration is validated using field samples.}, language = {en} } @misc{RethfeldtBrinkmannRiebeetal.2021, author = {Rethfeldt, Nina and Brinkmann, Pia and Riebe, Daniel and Beitz, Toralf and K{\"o}llner, Nicole and Altenberger, Uwe and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {Detection of Rare Earth Elements in Minerals and Soils by Laser-Induced Breakdown Spectroscopy (LIBS) Using Interval PLS}, series = {Zweitver{\"o}ffentlichungen der Universit{\"a}t Potsdam : Mathematisch-Naturwissenschaftliche Reihe}, journal = {Zweitver{\"o}ffentlichungen der Universit{\"a}t Potsdam : Mathematisch-Naturwissenschaftliche Reihe}, publisher = {Universit{\"a}tsverlag Potsdam}, address = {Potsdam}, issn = {1866-8372}, doi = {10.25932/publishup-55746}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus4-557469}, pages = {1 -- 17}, year = {2021}, abstract = {The numerous applications of rare earth elements (REE) has lead to a growing global demand and to the search for new REE deposits. One promising technique for exploration of these deposits is laser-induced breakdown spectroscopy (LIBS). Among a number of advantages of the technique is the possibility to perform on-site measurements without sample preparation. Since the exploration of a deposit is based on the analysis of various geological compartments of the surrounding area, REE-bearing rock and soil samples were analyzed in this work. The field samples are from three European REE deposits in Sweden and Norway. The focus is on the REE cerium, lanthanum, neodymium and yttrium. Two different approaches of data analysis were used for the evaluation. The first approach is univariate regression (UVR). While this approach was successful for the analysis of synthetic REE samples, the quantitative analysis of field samples from different sites was influenced by matrix effects. Principal component analysis (PCA) can be used to determine the origin of the samples from the three deposits. The second approach is based on multivariate regression methods, in particular interval PLS (iPLS) regression. In comparison to UVR, this method is better suited for the determination of REE contents in heterogeneous field samples. View Full-Text}, language = {en} } @misc{ZuehlkeMeilingRoderetal.2021, author = {Z{\"u}hlke, Martin and Meiling, Till Thomas and Roder, Phillip and Riebe, Daniel and Beitz, Toralf and Bald, Ilko and L{\"o}hmannsr{\"o}ben, Hans-Gerd and Janßen, Traute and Erhard, Marcel and Repp, Alexander}, title = {Photodynamic Inactivation of E. coli Bacteria via Carbon Nanodots}, series = {Zweitver{\"o}ffentlichungen der Universit{\"a}t Potsdam : Mathematisch-Naturwissenschaftliche Reihe}, journal = {Zweitver{\"o}ffentlichungen der Universit{\"a}t Potsdam : Mathematisch-Naturwissenschaftliche Reihe}, publisher = {Universit{\"a}t Potsdam}, address = {Potsdam}, issn = {1866-8372}, doi = {10.25932/publishup-53842}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus4-538425}, pages = {23742 -- 23749}, year = {2021}, abstract = {The increasing development of antibiotic resistance in bacteria has been a major problem for years, both in human and veterinary medicine. Prophylactic measures, such as the use of vaccines, are of great importance in reducing the use of antibiotics in livestock. These vaccines are mainly produced based on formaldehyde inactivation. However, the latter damages the recognition elements of the bacterial proteins and thus could reduce the immune response in the animal. An alternative inactivation method developed in this work is based on gentle photodynamic inactivation using carbon nanodots (CNDs) at excitation wavelengths λex > 290 nm. The photodynamic inactivation was characterized on the nonvirulent laboratory strain Escherichia coli K12 using synthesized CNDs. For a gentle inactivation, the CNDs must be absorbed into the cytoplasm of the E. coli cell. Thus, the inactivation through photoinduced formation of reactive oxygen species only takes place inside the bacterium, which means that the outer membrane is neither damaged nor altered. The loading of the CNDs into E. coli was examined using fluorescence microscopy. Complete loading of the bacterial cells could be achieved in less than 10 min. These studies revealed a reversible uptake process allowing the recovery and reuse of the CNDs after irradiation and before the administration of the vaccine. The success of photodynamic inactivation was verified by viability assays on agar. In a homemade flow photoreactor, the fastest successful irradiation of the bacteria could be carried out in 34 s. Therefore, the photodynamic inactivation based on CNDs is very effective. The membrane integrity of the bacteria after irradiation was verified by slide agglutination and atomic force microscopy. The method developed for the laboratory strain E. coli K12 could then be successfully applied to the important avian pathogens Bordetella avium and Ornithobacterium rhinotracheale to aid the development of novel vaccines.}, language = {en} } @misc{EichSchmaelzlinLoehmannsroeben2013, author = {Eich, Susanne and Schm{\"a}lzlin, Elmar and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {Distributed fiber optical sensing of oxygen with optical time domain reflectometry}, series = {Postprints der Universit{\"a}t Potsdam : Mathematisch-Naturwissenschaftliche Reihe}, journal = {Postprints der Universit{\"a}t Potsdam : Mathematisch-Naturwissenschaftliche Reihe}, number = {1085}, issn = {1866-8372}, doi = {10.25932/publishup-47665}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus4-476659}, pages = {16}, year = {2013}, abstract = {In many biological and environmental applications spatially resolved sensing of molecular oxygen is desirable. A powerful tool for distributed measurements is optical time domain reflectometry (OTDR) which is often used in the field of telecommunications. We combine this technique with a novel optical oxygen sensor dye, triangular-[4] phenylene (TP), immobilized in a polymer matrix. The TP luminescence decay time is 86 ns. The short decay time of the sensor dye is suitable to achieve a spatial resolution of some meters. In this paper we present the development and characterization of a reflectometer in the UV range of the electromagnetic spectrum as well as optical oxygen sensing with different fiber arrangements.}, language = {en} } @misc{ErlerRiebeBeitzetal.2019, author = {Erler, Alexander and Riebe, Daniel and Beitz, Toralf and L{\"o}hmannsr{\"o}ben, Hans-Gerd and Gebbers, Robin}, title = {Soil Nutrient Detection for Precision Agriculture Using Handheld Laser-Induced Breakdown Spectroscopy (LIBS) and Multivariate Regression Methods (PLSR, Lasso and GPR)}, series = {Postprints der Universit{\"a}t Potsdam : Mathematisch-Naturwissenschaftliche Reihe}, journal = {Postprints der Universit{\"a}t Potsdam : Mathematisch-Naturwissenschaftliche Reihe}, number = {815}, issn = {1866-8372}, doi = {10.25932/publishup-44418}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus4-444183}, pages = {19}, year = {2019}, abstract = {Precision agriculture (PA) strongly relies on spatially differentiated sensor information. Handheld instruments based on laser-induced breakdown spectroscopy (LIBS) are a promising sensor technique for the in-field determination of various soil parameters. In this work, the potential of handheld LIBS for the determination of the total mass fractions of the major nutrients Ca, K, Mg, N, P and the trace nutrients Mn, Fe was evaluated. Additionally, other soil parameters, such as humus content, soil pH value and plant available P content, were determined. Since the quantification of nutrients by LIBS depends strongly on the soil matrix, various multivariate regression methods were used for calibration and prediction. These include partial least squares regression (PLSR), least absolute shrinkage and selection operator regression (Lasso), and Gaussian process regression (GPR). The best prediction results were obtained for Ca, K, Mg and Fe. The coefficients of determination obtained for other nutrients were smaller. This is due to much lower concentrations in the case of Mn, while the low number of lines and very weak intensities are the reason for the deviation of N and P. Soil parameters that are not directly related to one element, such as pH, could also be predicted. Lasso and GPR yielded slightly better results than PLSR. Additionally, several methods of data pretreatment were investigated.}, language = {en} } @misc{RiebeErlerBrinkmannetal.2019, author = {Riebe, Daniel and Erler, Alexander and Brinkmann, Pia and Beitz, Toralf and L{\"o}hmannsr{\"o}ben, Hans-Gerd and Gebbers, Robin}, title = {Comparison of Calibration Approaches in Laser-Induced Breakdown Spectroscopy for Proximal Soil Sensing in Precision Agriculture}, series = {Postprints der Universit{\"a}t Potsdam Mathematisch-Naturwissenschaftliche Reihe}, journal = {Postprints der Universit{\"a}t Potsdam Mathematisch-Naturwissenschaftliche Reihe}, number = {786}, issn = {1866-8372}, doi = {10.25932/publishup-44007}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus4-440079}, pages = {16}, year = {2019}, abstract = {The lack of soil data, which are relevant, reliable, affordable, immediately available, and sufficiently detailed, is still a significant challenge in precision agriculture. A promising technology for the spatial assessment of the distribution of chemical elements within fields, without sample preparation is laser-induced breakdown spectroscopy (LIBS). Its advantages are contrasted by a strong matrix dependence of the LIBS signal which necessitates careful data evaluation. In this work, different calibration approaches for soil LIBS data are presented. The data were obtained from 139 soil samples collected on two neighboring agricultural fields in a quaternary landscape of northeast Germany with very variable soils. Reference analysis was carried out by inductively coupled plasma optical emission spectroscopy after wet digestion. The major nutrients Ca and Mg and the minor nutrient Fe were investigated. Three calibration strategies were compared. The first method was based on univariate calibration by standard addition using just one soil sample and applying the derived calibration model to the LIBS data of both fields. The second univariate model derived the calibration from the reference analytics of all samples from one field. The prediction is validated by LIBS data of the second field. The third method is a multivariate calibration approach based on partial least squares regression (PLSR). The LIBS spectra of the first field are used for training. Validation was carried out by 20-fold cross-validation using the LIBS data of the first field and independently on the second field data. The second univariate method yielded better calibration and prediction results compared to the first method, since matrix effects were better accounted for. PLSR did not strongly improve the prediction in comparison to the second univariate method.}, language = {en} } @misc{MorgnerLecointreCharbonniereetal.2014, author = {Morgner, Frank and Lecointre, Alexandre and Charbonni{\`e}re, Loic J. and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {Detecting free hemoglobin in blood plasma and serum with luminescent terbium complexes}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus4-99485}, pages = {6}, year = {2014}, abstract = {Hemolysis, the rupturing of red blood cells, can result from numerous medical conditions (in vivo) or occur after collecting blood specimen or extracting plasma and serum out of whole blood (in vitro). In clinical laboratory practice, hemolysis can be a serious problem due to its potential to bias detection of various analytes or biomarkers. Here we present the first ''mix-and-measure'' method to assess the degree of hemolysis in biosamples using luminescence spectroscopy. Luminescent terbium complexes (LTC) were studied in the presence of free hemoglobin (Hb) as indicators for hemolysis in TRIS-buffer, and in fresh human plasma with absorption, excitation and emission measurements. Our findings indicate dynamic as well as resonance energy transfer (FRET) between the LTC and the porphyrin ligand of hemoglobin. This transfer leads to a decrease in luminescence intensity and decay time even at nanomolar hemoglobin concentrations either in buffer or plasma. Luminescent terbium complexes are very sensitive to free hemoglobin in buffer and blood plasma. Due to the instant change in luminescence properties of the LTC in presence of Hb it is possible to access the concentration of hemoglobin via spectroscopic methods without incubation time or further treatment of the sample thus enabling a rapid and sensitive detection of hemolysis in clinical diagnostics.}, language = {en} } @misc{CywińskiNonoCharbonniereetal.2014, author = {Cywiński, Piotr J. and Nono, Katia Nchimi and Charbonni{\`e}re, Lo{\"i}c J. and Hammann, Tommy and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {Photophysical evaluation of a new functional terbium complex in FRET-based time-resolved homogenous fluoroassays}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus4-95390}, pages = {6060 -- 6067}, year = {2014}, abstract = {A new functional luminescent lanthanide complex (LLC) has been synthesized with terbium as a central lanthanide ion and biotin as a functional moiety. Unlike in typical lanthanide complexes assembled via carboxylic moieties, in the presented complex, four phosphate groups are chelating the central lanthanide ion. This special chemical assembly enhances the complex stability in phosphate buffers conventionally used in biochemistry. The complex synthesis strategy and photophysical properties are described as well as the performance in time-resolved F{\"o}rster Resonance Energy Transfer (FRET) assays. In those assays, this biotin-LLC transferred energy either to acceptor organic dyes (Cy5 or AF680) labelled on streptavidin or to quantum dots (QD655 or QD705) surface-functionalised with streptavidins. The permanent spatial donor-acceptor proximity is assured through strong and stable biotin-streptavidin binding. The energy transfer is evidenced from the quenching observed in donor emission and from a decrease in donor luminescence decay, both associated with simultaneous increase in acceptor intensity and in the decay time. The dye-based assays are realised in TRIS and in PBS, whereas QD-based systems are studied in borate buffer. The delayed emission analysis allows for quantifying the recognition process and for auto-fluorescence-free detection, which is particularly relevant for application in bioanalysis. In accordance with F{\"o}rster theory, F{\"o}rster-radii (R0) were found to be around 60 {\AA} for organic dyes and around 105 {\AA} for QDs. The FRET efficiency (η) reached 80\% and 25\% for dye and QD acceptors, respectively. Physical donor-acceptor distances (r) have been determined in the range 45-60 {\AA} for organic dye acceptors, while for acceptor QDs between 120 {\AA} and 145 {\AA}. This newly synthesised biotin-LLC extends the class of highly sensitive analytical tools to be applied in the bioanalytical methods such as time-resolved fluoroimmunoassays (TR-FIA), luminescent imaging and biosensing.}, language = {en} } @misc{McQuadeO'BrienDoerretal.2013, author = {McQuade, D. Tyler and O'Brien, Alexander G. and D{\"o}rr, Markus and Rajaratnam, Rajathees and Eisold, Ursula and Monnanda, Bopanna and Nobuta, Tomoya and L{\"o}hmannsr{\"o}ben, Hans-Gerd and Meggers, Eric and Seeberger, Peter H.}, title = {Continuous synthesis of pyridocarbazoles and initial photophysical and bioprobe characterization}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus4-95214}, pages = {4067 -- 4070}, year = {2013}, abstract = {Pyridocarbazoles when ligated to transition metals yield high affinity kinase inhibitors. While batch photocyclizations enable the synthesis of these heterocycles, the non-oxidative Mallory reaction only provides modest yields and difficult to purify mixtures. We demonstrate here that a flow-based Mallory cyclization provides superior results and enables observation of a clear isobestic point. The flow method allowed us to rapidly synthesize ten pyridocarbazoles and for the first time to document their interesting photophysical attributes. Preliminary characterization reveals that these molecules might be a new class of fluorescent bioprobe.}, language = {en} } @misc{ReichLoehmannsroebenSchael2003, author = {Reich, Oliver and L{\"o}hmannsr{\"o}ben, Hans-Gerd and Schael, Frank}, title = {Optical sensing with photon density waves: investigation of model media}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus-13147}, year = {2003}, abstract = {Investigations with frequency domain photon density waves allow elucidation of absorption and scattering properties of turbid media. The temporal and spatial propagation of intensity modulated light with frequencies up to more than 1 GHz can be described by the P1 approximation to the Boltzmann transport equation. In this study, we establish requirements for the appropriate choice of turbid model media and characterize mixtures of isosulfan blue as absorber and polystyrene beads as scatterer. For these model media, the independent determination of absorption and reduced scattering coefficients over large absorber and scatterer concentration ranges is demonstrated with a frequency domain photon density wave spectrometer employing intensity and phase measurements at various modulation frequencies.}, language = {en} } @misc{DoscheMicklerLoehmannsroebenetal.2007, author = {Dosche, Carsten and Mickler, Wulfhard and L{\"o}hmannsr{\"o}ben, Hans-Gerd and Agenet, Nicolas and Vollhardt, K. Peter C.}, title = {Photoinduced electron transfer in [N]phenylenes}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus-12463}, year = {2007}, abstract = {First studies of electron transfer in [N]phenylenes were performed in bimolecular quenching reactions of angular [3]- and triangular [4]phenylene with various electron acceptors. The relation between the quenching rate constants kq and the free energy change of the electron transfer (ΔG0CS ) could be described by the Rehm-Weller equation. From the experimental results, a reorganization energy λ of 0.7 eV was derived. Intramolecular electron transfer reactions were studied in an [N]phenylene bichomophore and a corresponding reference compound. Fluorescence lifetime and quantum yield of the bichromophor display a characteristic dependence on the solvent polarity, whereas the corresponding values of the reference compound remain constant. From the results, a nearly isoenergonic ΔG0CS can be determined. As the triplet quantum yield is nearly independent of the polarity, charge recombination leads to the population of the triplet state.}, language = {en} } @misc{SchultzeLemkeLoehmannsroeben2004, author = {Schultze, Rainer H. and Lemke, Matthias and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {Laser-induced fluorescence (LIF) spectroscopy for the in situ analysis of petroleum product-contaminated soils}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus-12271}, year = {2004}, abstract = {Contents: Introduction Experimental Techniques: The LIF demonstrator unit - The LIF demonstrator unit - The mobile LIF spectrometer OPTIMOS - Investigated petroleum products and soil samples Results and Discussion: Photophysical properties of the petroleum products LIF spectroscopic investigations of oil-spiked samples LIF spectroscopic investigations of real-world soils Conclusions}, language = {en} } @misc{EngelhardKumkeLoehmannsroeben2006, author = {Engelhard, Sonja and Kumke, Michael Uwe and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {OPQS - optical process and quality sensing : exemplary applications in the beerbrewing and polyurethane foaming processes}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus-12191}, year = {2006}, abstract = {Optical methods play an important role in process analytical technologies (PAT). Four examples of optical process and quality sensing (OPQS) are presented, which are based on three important experimental techniques: near-infrared absorption, luminescence quenching, and a novel method, photon density wave (PDW) spectroscopy. These are used to evaluate four process and quality parameters related to beer brewing and polyurethane (PU) foaming processes: the ethanol content and the oxygen (O2) content in beer, the biomass in a bioreactor, and the cellular structures of PU foam produced in a pilot production plant.}, language = {en} } @misc{SchmaelzlinWalzKlimantetal.2006, author = {Schm{\"a}lzlin, Elmar and Walz, Bernd and Klimant, Ingo and Schewe, Bettina and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {Monitoring hormone-induced oxygen consumption in the salivary glands of the blowfly, Calliphora vicina, by use of luminescent microbeads}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus-12206}, year = {2006}, abstract = {The salivary glands of the blowfly were injected with luminescent oxygen-sensitive microbeads. The changes in oxygen content within individual gland tubules during hormone-induced secretory activity were quantified. The measurements are based on an upgraded phase-modulation technique, where the phase shift of the sensor phosphorescence is determined independently from concentration and background signals. We show that the combination of a lock-in amplifier with a fluorescence microscope results in a convenient setup to measure oxygen concentrations within living animal tissues at the cellular level.}, language = {en} } @misc{HildebrandtCharbonniereZiesseletal.2006, author = {Hildebrandt, Nico and Charbonni{\`e}re, Lo{\"i}c J. and Ziessel, Raymond F. and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {Quantum dots as resonance energy transfer acceptors for monitoring biological interactions}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus-12213}, year = {2006}, abstract = {Quantum dots (QDs) are common as luminescing markers for imaging in biological applications because their optical properties seem to be inert against their surrounding solvent. This, together with broad and strong absorption bands and intense, sharp tuneable luminescence bands, makes them interesting candidates for methods utilizing Forster Resonance Energy Transfer (FRET), e. g. for sensitive homogeneous fluoroimmunoassays (FIA). In this work we demonstrate energy transfer from Eu3+-trisbipyridin (Eu-TBP) donors to CdSe-ZnS-QD acceptors in solutions with and without serum. The QDs are commercially available CdSe-ZnS core-shell particles emitting at 655 nm (QD655). The FRET system was achieved by the binding of the streptavidin conjugated donors with the biotin conjugated acceptors. After excitation of Eu-TBP and as result of the energy transfer, the luminescence of the QD655 acceptors also showed lengthened decay times like the donors. The energy transfer efficiency, as calculated from the decay times of the bound and the unbound components, amounted to 37\%. The Forster-radius, estimated from the absorption and emission bands, was ca. 77{\AA}. The effective binding ratio, which not only depends on the ratio of binding pairs but also on unspecific binding, was obtained from the donor emission dependent on the concentration. As serum promotes unspecific binding, the overall FRET efficiency of the assay was reduced. We conclude that QDs are good substitutes for acceptors in FRET if combined with slow decay donors like Europium. The investigation of the influence of the serum provides guidance towards improving binding properties of QD assays.}, language = {en} } @misc{SchmaelzlinDongenKlimantetal.2005, author = {Schm{\"a}lzlin, Elmar and Dongen, Joost T. van and Klimant, Ingo and Marmod{\´e}e, Bettina and Steup, Martin and Fishahn, Joachim and Geigenberger, Peter and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {An optical multifrequency phase-modulation method using microbeads for measuring intracellular oxygen concentrations in plants}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus-12232}, year = {2005}, abstract = {A technique has been developed to measure absolute intracellular oxygen concentrations in green plants. Oxygen-sensitive phosphorescent microbeads were injected into the cells and an optical multifrequency phase-modulation technique was used to discriminate the sensor signal from the strong autofluorescence of the plant tissue. The method was established using photosynthesis-competent cells of the giant algae Chara corallina L., and was validated by application to various cell types of other plant species.}, language = {en} } @misc{LemkeFernandezTrujilloLoehmannsroeben2005, author = {Lemke, Matthias and Fern{\´a}ndez-Trujillo, Rebeca and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {In-situ LIF analysis of biological and petroleum-based hydraulic oils on soil}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus-12268}, year = {2005}, abstract = {Absorption and fluorescence properties of 4 hydraulic oils (3 biological and 1 petroleum-based) were investigated. In-situ LIF (laser-induced fluorescence) analysis of the oils on a brown sandy loam soil was performed. With calibration, quantitative detection was achieved. Estimated limits of detection were below ca. 500 mg/kg for the petroleum-based oil and ca. 2000 mg/kg for one biological oil. A semi-quantitative classification scheme is proposed for monitoring of the biological oils. This approach was applied to investigate the migration of a biological oil in soil-containing compartments, namely a soil column and a soil bed.}, language = {en} } @misc{DoscheLoehmannsroebenBieseretal.2002, author = {Dosche, Carsten and L{\"o}hmannsr{\"o}ben, Hans-Gerd and Bieser, A. and Dosa, P. I. and Han, S. and Iwamoto, M. and Schleifenbaum, A. and Vollhardt, K. Peter C.}, title = {Photophysical properties of [N]phenylenes}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus-11936}, year = {2002}, abstract = {In the present study, photophysical properties of [N]phenylenes were studied by means of stationary and time-resolved absorption and fluorescence spectroscopy (in THF at room temperature). For biphenylene (1) and linear [3]phenylene (2a), internal conversion (IC) with quantum yields ΦIC > 0.99 is by far the dominant mechanism of S1 state deactivation. Angular [3]phenylene (3a), the zig-zag [4]- and [5]phenylenes (3b), (3c), and the triangular [4]phenylene (4) show fluorescence emission with fluorescence quantum yieds and lifetimes between ΦF = 0.07 for (3a) and 0.21 for (3c) and τF = 20 ns for (3a) and 81 ns for (4). Also, compounds (3) and (4) exhibit triplet formation upon photoexcitation with quantum yields as high as ΦISC = 0.45 for (3c). The strong differences in the fluorescence properties and in the triplet fromation efficiencies between (1) and (2a) on one hand and (3) and (4) on the other are related to the remarkable variation of the internal conversion (IC) rate constants kIC. A tentative classification of (1) and (2a) as "fast IC compounds", with kIC > 109 s-1, and of (3) and (4) as "slow IC compounds", with kIC ≈ 107 s-1, is suggested. This classification cannot simply be related to H{\"u}ckel's rule-type concepts of aromaticity, because the group of "fast IC compounds" consists of "antiaromatic" (1) and "aromatic" (2a), and the group of "slow IC compounds" consists of "antiaromatic" (3b), (4) and "aromatic" (3a), (3c). The IC in the [N]phenylenes is discussed within the framework of the so-called energy gap law established for non-radiative processes in benzenoid hydrocarbons.}, language = {en} } @misc{LoehmannsroebenBeitzLuadienetal.2004, author = {L{\"o}hmannsr{\"o}ben, Hans-Gerd and Beitz, Toralf and Luadien, Robert and Schultze, Rainer}, title = {Laser-based ion mobility spectrometry for sensing of aromatic compounds}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus-11892}, year = {2004}, abstract = {The drift time spectra of polycyclic aromatic hydrocarbons (PAH), alkylbenzenes and alkylphenylethers were recorded with a laser-based ion mobility (IM) spectrometer. The ion mobilities of all compounds were determined in helium as drift gas. This allows the calculation of the diffusion cross sections (Omegacalc) on the basis of the exact hard sphere scattering model (EHSSM) and their comparison with the experimentally determined diffusion cross sections (Omegaexp). These Omegaexp/Omegacalc-correlations are presented for molecules with a rigid structure like PAH and prove the reliability of the theoretical model and experimental method. The increase of the selectivity of IM spectrometry is demonstrated using resonance enhanced multiphoton ionisation (REMPI) at atmospheric pressure, realized by tuneable lasers. The REMPI spectra of nine alkylbenzenes and alkylphenylethers are investigated. On the basis of these spectra, the complete qualitative distinction of eight compounds in a mixture is shown. These experiments are extended to alkylbenzene isomer mixtures.}, language = {en} } @misc{HoernerLauKantoretal.2004, author = {H{\"o}rner, Gerald and Lau, Steffen and Kantor, Zoltan and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {Isotope selective analysis of CO2 with tunable diode laser (TDL) spectroscopy in the NIR}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus-10167}, year = {2004}, abstract = {The performance of a home-built tunable diode laser (TDL) spectrometer, aimed at multi-line detection of carbon dioxide, has been evaluated and optimized. In the regime of the (3001)III / (000) band of 12CO2 around 1.6 μm, the dominating isotope species 12CO2, 13CO2, and 12C18O16O were detected simultaneously without interference by water vapor. Detection limits in the range of few ppmv were obtained for each species utilizing wavelength modulation (WM) spectroscopy with balanced detection in a long-path absorption cell set-up. High sensitivity in conjunction with high precision —typically ±1 per mille and ±6 per mille for 3\% and 0.7\% of CO2, respectively— renders this experimental approach a promising analytical concept for isotope-ratio determination of carbon dioxide in soil and breath gas. For a moderate 12CO2 line, the pressure dependence of the line profile was characterized in detail, to account for pressure effects on sensitive measurements.}, subject = {Isotopenverh{\"a}ltnis}, language = {en} } @misc{NiederkruegerSalbBecketal.2006, author = {Niederkr{\"u}ger, Matthias and Salb, Christian and Beck, Michael and Hildebrandt, Niko and L{\"o}hmannsr{\"o}ben, Hans-Gerd and Marowsky, Gerd}, title = {Improvement of a fluorescence immunoassay with a compact diode-pumped solid state laser at 315 nm}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus-10150}, year = {2006}, abstract = {We demonstrate the improvement of fluorescence immunoassay (FIA) diagnostics in deploying a newly developed compact diode-pumped solid state (DPSS) laser with emission at 315 nm. The laser is based on the quasi-three-level transition in Nd:YAG at 946 nm. The pulsed operation is either realized by an active Q-switch using an electro-optical device or by introduction of a Cr4+:YAG saturable absorber as passive Q-switch element. By extra-cavity second harmonic generation in different nonlinear crystal media we obtained blue light at 473 nm. Subsequent mixing of the fundamental and the second harmonic in a β-barium-borate crystal provided pulsed emission at 315 nm with up to 20 μJ maximum pulse energy and 17 ns pulse duration. Substitution of a nitrogen laser in a FIA diagnostics system by the DPSS laser succeeded in considerable improvement of the detection limit. Despite significantly lower pulse energies (7 μJ DPSS laser versus 150 μJ nitrogen laser), in preliminary investigations the limit of detection was reduced by a factor of three for a typical FIA.}, subject = {Immunoassay}, language = {en} } @misc{HoernerLauLoehmannsroeben2004, author = {H{\"o}rner, Gerald and Lau, Steffen and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {NIR-diode laser spectroscopy for isotope-selective sensing of soil-respired carbon dioxide}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus-10148}, year = {2004}, abstract = {The performance of a home-built tunable diode laser (TDL) spectrometer has been optimized regarding multi-line detection of carbon dioxide in natural gases. In the regime of the (3001)III ← (000) band of 12CO2 around 1.6 μm, the dominating isotope species 12CO2, 13CO2, and 12C18O16O were detected simultaneously. In contrast to most established techniques, selective measurements are performed without any sample preparation. This is possible since the CO2 detection is free of interference from water, ubiquitous in natural gases. Detection limits in the range of a few ppmv were obtained for each species utilizing wavelength modulation (WM) spectroscopy with balanced detection in a long-path absorption cell set-up. Linear calibration plots cover a dynamic range of four orders of magnitude, allowing for quantitative CO2 detection in various samples, like soil and breath gas. High isotopic resolution enables the excellent selectivity, sensitivity, and stability of the chosen analytical concept. The obtained isotopic resolution of typically ± 1.0 per mille and ± 1.5 per mille (for 3 vol. \% and 0.7 vol. \% of CO2, respectively) offers a promising analytical tool for isotope-ratio determination of carbon dioxide in soil gas. Preliminary experiments on soil respiration for the first time combine the on-line quantification of the overall carbon dioxide content with an optode sensor and isotopic determination (TDL system) of natural gas species.}, subject = {Kohlendioxid}, language = {en} } @misc{LauSalffnerLoehmannsroeben2006, author = {Lau, Steffen and Salffner, Katharina and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {Isotopic resolution of carbon monoxide and carbon dioxide by NIR diode laser spectroscopy}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus-10135}, year = {2006}, abstract = {Near-infrared (NIR) absorption spectroscopy with tunable diode lasers allows the simultaneous detection of the three most important isotopologues of carbon dioxide (12CO2, 13CO2, 12C18O16O) and carbon monoxide (12CO, 13CO, 12C18O). The flexible and compact fiber-optic tunable diode laser absorption spectrometer (TDLAS) allows selective measurements of CO2 and CO with high isotopic resolution without sample preparation since there is no interference with water vapour. For each species, linear calibration plots with a dynamic range of four orders of magnitude and detection limits (LOD) in the range of a few ppm were obtained utilizing wavelength modulation spectroscopy (WMS) with balanced detection in a Herriott-type multipass cell. The high performance of the apparatus is illustrated by fill-evacuation-refill cycles.}, subject = {Isotop}, language = {en} } @misc{LoehmannsroebenBeckHildebrandtetal.2006, author = {L{\"o}hmannsr{\"o}ben, Hans-Gerd and Beck, Michael and Hildebrandt, Niko and Schm{\"a}lzlin, Elmar and van Dongen, Joost T.}, title = {New challenges in biophotonics : laser-based fluoroimmuno analysis and in-vivo optical oxygen monitoring}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus-10120}, year = {2006}, abstract = {Two examples of our biophotonic research utilizing nanoparticles are presented, namely laser-based fluoroimmuno analysis and in-vivo optical oxygen monitoring. Results of the work include significantly enhanced sensitivity of a homogeneous fluorescence immunoassay and markedly improved spatial resolution of oxygen gradients in root nodules of a legume species.}, subject = {Sauerstoff}, language = {en} } @misc{BeckHildebrandtLoehmannsroeben2006, author = {Beck, Michael and Hildebrandt, Niko and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {Quantum dots as acceptors in FRET-assays containing serum}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus-9504}, year = {2006}, abstract = {Quantum dots (QDs) are common as luminescing markers for imaging in biological applications because their optical properties seem to be inert against their surrounding solvent. This, together with broad and strong absorption bands and intense, sharp tuneable luminescence bands, makes them interesting candidates for methods utilizing F{\"o}rster Resonance Energy Transfer (FRET), e. g. for sensitive homogeneous fluoroimmunoassays (FIA). In this work we demonstrate energy transfer from Eu3+-trisbipyridin (Eu-TBP) donors to CdSe-ZnS-QD acceptors in solutions with and without serum. The QDs are commercially available CdSe-ZnS core-shell particles emitting at 655 nm (QD655). The FRET system was achieved by the binding of the streptavidin conjugated donors with the biotin conjugated acceptors. After excitation of Eu-TBP and as result of the energy transfer, the luminescence of the QD655 acceptors also showed lengthened decay times like the donors. The energy transfer efficiency, as calculated from the decay times of the bound and the unbound components, amounted to 37\%. The F{\"o}rster-radius, estimated from the absorption and emission bands, was ca. 77 {\AA}. The effective binding ratio, which not only depends on the ratio of binding pairs but also on unspecific binding, was obtained from the donor emission dependent on the concentration. As serum promotes unspecific binding, the overall FRET efficiency of the assay was reduced. We conclude that QDs are good substitutes for acceptors in FRET if combined with slow decay donors like Europium. The investigation of the influence of the serum provides guidance towards improving binding properties of QD assays.}, subject = {Quantenpunkt}, language = {en} }