@misc{SchwarzeRiemerMuelleretal.2019, author = {Schwarze, Thomas and Riemer, Janine and M{\"u}ller, Holger and John, Leonard and Holdt, Hans-J{\"u}rgen and Wessig, Pablo}, title = {Na+ Selective Fluorescent Tools Based on Fluorescence Intensity Enhancements, Lifetime Changes, and on a Ratiometric Response}, series = {Postprints der Universit{\"a}t Potsdam : Mathematisch-Naturwissenschaftliche Reihe}, journal = {Postprints der Universit{\"a}t Potsdam : Mathematisch-Naturwissenschaftliche Reihe}, number = {1136}, issn = {1866-8372}, doi = {10.25932/publishup-43748}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus4-437482}, pages = {13}, year = {2019}, abstract = {Over the years, we developed highly selective fluorescent probes for K+ in water, which show K+-induced fluorescence intensity enhancements, lifetime changes, or a ratiometric behavior at two emission wavelengths (cf. Scheme 1, K1-K4). In this paper, we introduce selective fluorescent probes for Na+ in water, which also show Na+ induced signal changes, which are analyzed by diverse fluorescence techniques. Initially, we synthesized the fluorescent probes 2, 4, 5, 6 and 10 for a fluorescence analysis by intensity enhancements at one wavelength by varying the Na+ responsive ionophore unit and the fluorophore moiety to adjust different K-d values for an intra- or extracellular Na+ analysis. Thus, we found that 2, 4 and 5 are Na+ selective fluorescent tools, which are able to measure physiologically important Na+ levels at wavelengths higher than 500 nm. Secondly, we developed the fluorescent probes 7 and 8 to analyze precise Na+ levels by fluorescence lifetime changes. Herein, only 8 (K-d=106 mm) is a capable fluorescent tool to measure Na+ levels in blood samples by lifetime changes. Finally, the fluorescent probe 9 was designed to show a Na+ induced ratiometric fluorescence behavior at two emission wavelengths. As desired, 9 (K-d=78 mm) showed a ratiometric fluorescence response towards Na+ ions and is a suitable tool to measure physiologically relevant Na+ levels by the intensity change of two emission wavelengths at 404 nm and 492 nm.}, language = {en} } @misc{SchwarzeMuellerAstetal.2014, author = {Schwarze, Thomas and M{\"u}ller, Holger and Ast, Sandra and Steinbr{\"u}ck, D{\"o}rte and Eidner, Sascha and Geißler, Felix and Kumke, Michael Uwe and Holdt, Hans-J{\"u}rgen}, title = {Fluorescence lifetime-based sensing of sodium by an optode}, publisher = {The Royal Society of Chemistry}, address = {Cambridge}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus4-76785}, pages = {14167 -- 14170}, year = {2014}, abstract = {We report a 1,2,3-triazol fluoroionophore for detecting Na+ that shows in vitro enhancement in the Na+-induced fluorescence intensity and decay time. The Na+-selective molecule 1 was incorporated into a hydrogel as a part of a fiber optical sensor. This sensor allows the direct determination of Na+ in the range of 1-10 mM by measuring reversible fluorescence decay time changes.}, language = {en} }