@article{KhademHilleLoehmannsroebenetal.2016, author = {Khadem, S. M. J. and Hille, Carsten and L{\"o}hmannsr{\"o}ben, Hans-Gerd and Sokolov, Igor M.}, title = {What information is contained in the fluorescence correlation spectroscopy curves, and where}, series = {Physical review : E, Statistical, nonlinear and soft matter physics}, volume = {94}, journal = {Physical review : E, Statistical, nonlinear and soft matter physics}, publisher = {American Physical Society}, address = {College Park}, issn = {2470-0045}, doi = {10.1103/PhysRevE.94.022407}, pages = {8}, year = {2016}, language = {en} } @article{LoehmannsroebenSchaelReichetal.2000, author = {L{\"o}hmannsr{\"o}ben, Hans-Gerd and Schael, Frank and Reich, Oliver and Lemke, Matthias and Schober, Lars}, title = {Untersuchung von organischer Bodensubstanz und Bodengasen mit laser-spektroskopischer in-situ Meßtechnik}, year = {2000}, language = {de} } @article{HilleLahnLoehmannsroebenetal.2009, author = {Hille, Carsten and Lahn, Mattes and L{\"o}hmannsr{\"o}ben, Hans-Gerd and Dosche, Carsten}, title = {Two-photon fluorescence lifetime imaging of intracellular chloride in cockroach salivary glands}, issn = {1474-905X}, doi = {10.1039/B813797H}, year = {2009}, language = {en} } @article{MeilingCywinskiLoehmannsroeben2018, author = {Meiling, Till Thomas and Cywinski, Piotr J. and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {Two-Photon excitation fluorescence spectroscopy of quantum dots}, series = {The journal of physical chemistry : C, Nanomaterials and interfaces}, volume = {122}, journal = {The journal of physical chemistry : C, Nanomaterials and interfaces}, number = {17}, publisher = {American Chemical Society}, address = {Washington}, issn = {1932-7447}, doi = {10.1021/acs.jpcc.7b12345}, pages = {9641 -- 9647}, year = {2018}, abstract = {The applications of quantum dots (QDs) in two-photon (2P) excitation applications demand reliable data about their 2P absorption (2PA) cross sections (sigma(2PA)). In the present study, sigma(2PA) values have been determined for a series of commercial colloidal CdSe/ZnS QDs and CdSeTe/ZnS QDs in aqueous media. For the first time for these QDs, the sigma(2PA) values have been determined over a wide spectral range, that is, between 720 and 900 nm, and are compared to the extinction coefficient (epsilon) values obtained under one-photon (1P) excitation. Furthermore, we present a QD in combination with an organic dye in a biotin-streptavidin Forster resonance energy transfer bioassay under 1P and 2P excitation. The results for the bioassay under 2P excitation are compared to those obtained under 1P excitation. The results demonstrate that in the case of the 2P excitation, higher sensitivity can be achieved because of an improved signal-to-noise ratio.}, language = {en} } @article{CywinskiPietraszkiewiczMaciejczyketal.2016, author = {Cywinski, Piotr J. and Pietraszkiewicz, Marek and Maciejczyk, Michal and Gorski, Krzysztof and Hammann, Tommy and Liermann, Konstanze and Paulke, Bernd-Reiner and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {Total protein concentration quantification using nanobeads with a new highly luminescent terbium(III) complex}, series = {RSC Advances}, volume = {6}, journal = {RSC Advances}, publisher = {Royal Society of Chemistry}, address = {Cambridge}, issn = {2046-2069}, doi = {10.1039/c6ra23207h}, pages = {115068 -- 115073}, year = {2016}, abstract = {Total protein concentration (TPC) is a key parameter in many biochemical experiments and its quantification is often necessary for isolation, separation, and analysis of proteins. A sensitive and rapid nanobead-based TPC quantification assay based on Forster Resonance Energy Transfer (FRET) has been developed. A new, highly luminescent Tb(III) complex has been synthesised and applied as donor in this FRET assay with an organic dye (Cy5) as acceptor. FRET-induced changes in luminescence have been investigated both at donor and acceptor emission wavelength using time-resolved luminescence spectroscopy with time-gated detection. In the assay, the Tb(III) complex and fine-tuned polyglycidyl methacrylate (PGMA) nanobeads ensure that an improvement in sensitivity and background reduction is achieved. Using 40 nm large PGMA nanobeads loaded with the Tb(III) complex, it is possible to determine TPC down to 50 ng mL(-1) in just 10 minutes. Through specific assay components the sensitivity has been improved when compared to existing nanobead-based assays and to currently known commercial methods. Additionally, the assay is relatively insensitive to the presence of contaminants, such as non-ionic detergents commonly found in biological samples. Due to no need for any centrifugal steps, this mix-and-measure bioassay can easily be implemented into routine TPC quantification protocols in biochemical laboratories.}, language = {en} } @article{HilleBergBresseletal.2008, author = {Hille, Carsten and Berg, Maik and Bressel, Lena and Munzke, Dorit and Primus, Philipp and L{\"o}hmannsr{\"o}ben, Hans-Gerd and Dosche, Carsten}, title = {Time-domain fluorescence lifetime imaging for intracellular pH sensing in living tissues}, doi = {10.1007/s00216-008-2147-0}, year = {2008}, abstract = {pH sensing in living cells represents one of the most prominent topics in biochemistry and physiology. In this study we performed one-photon and two-photon time-domain fluorescence lifetime imaging with a laser-scanning microscope using the time-correlated single-photon counting technique for imaging intracellular pH levels. The suitability of different commercial fluorescence dyes for lifetime-based pH sensing is discussed on the basis of in vitro as well of in situ measurements. Although the tested dyes are suitable for intensity-based ratiometric measurements, for lifetime- based techniques in the time-domain so far only BCECF seems to meet the requirements of reliable intracellular pH recordings in living cells.}, language = {en} } @article{SchwarzeMicklerDoscheetal.2010, author = {Schwarze, Thomas and Mickler, Wulfhard and Dosche, Carsten and Flehr, Roman and Klamroth, Tillmann and L{\"o}hmannsr{\"o}ben, Hans-Gerd and Saalfrank, Peter and Holdt, Hans-J{\"u}rgen}, title = {Systematic investigation of photoinduced electron transfer controlled by internal charge transfer and its consequences for selective PdCl2 coordination}, issn = {0947-6539}, doi = {10.1002/chem.200902281}, year = {2010}, abstract = {Fluoroionophores of fluorophore-spacer-receptor format were prepared for detection of PdCl2 by fluorescence enhancement. The fluorophore probes 1-13 consist of a fluorophore group, in alkyl spacer and a dithiomaleonitrile PdCl2 receptor. First, varying the length of the alkylene spacer (compounds 1-3) revealed, dominant through-space pathway for oxidative photoinduced electron transfer (PET) in CH2-bridged dithiomaleonitrile fluoroionophores. Second. fluorescent probes 4-9 containing two anthracene or pyrene fragments connected through CH2 bridges to the dithiomaleonitrile unit were synthesized. Modulation of the oxidation potential (E-Ox) through electron-withdrawing or -donating groups on the anthracene moiety regulates file thermodynamic driving force for oxidative PET (Delta G(PET)) in bis(anthrylmethylthio)maleonitriles and therefore the fluorescence quantum yields (Phi(f)), too. The new concept was confirmed and transferred to pyrenyl ligands, and fluorescence enhancements (FE) greater than 3.2 in the presence of PdCl2 were achieved by 7 and 8 (FE=5.4 and 5.2). Finally, for comparison, monofluorophore ligands 10-13 were synthesized.}, language = {en} } @article{SchwarzeMicklerDoscheetal.2010, author = {Schwarze, Thomas and Mickler, Wulfhard and Dosche, Carsten and Flehr, Roman and Klamroth, Tillmann and L{\"o}hmannsr{\"o}ben, Hans-Gerd and Saalfrank, Peter and Holdt, Hans-J{\"u}rgen}, title = {Systematic investigation of photoinduced electron transfer controlled by internal charge transfer and its consequences for selective PdCl2 coordination}, issn = {0947-6539}, year = {2010}, abstract = {Fluoroionophores of fluorophore-spacer-receptor format were prepared for detection of PdCl2 by fluorescence enhancement. The fluorescent probes 1-13 consist of a fluorophore group, an alkyl spacer and a dithiomaleonitrile PdCl2 receptor. First, varying the length of the alkylene spacer (compounds 1-3) revealed a dominant through-space pathway for oxidative photoinduced electron transfer (PET) in CH2-bridged dithiomaleonitrile fluoroionophores. Second, fluorescent probes 4-9 containing two anthracene or pyrene fragments connected through CH2 bridges to the dithiomaleonitrile unit were synthesized. Modulation of the oxidation potential (EOx) through electron-withdrawing or -donating groups on the anthracene moiety regulates the thermodynamic driving force for oxidative PET (GPET) in bis(anthrylmethylthio)maleonitriles and therefore the fluorescence quantum yields (f), too. The new concept was confirmed and transferred to pyrenyl ligands, and fluorescence enhancements (FE) greater than 3.2 in the presence of PdCl2 were achieved by 7 and 8 (FE=5.4 and 5.2). Finally, for comparison, monofluorophore ligands 10-13 were synthesized.}, language = {en} } @article{EllisBlandHawthornLawrenceetal.2012, author = {Ellis, S. C. and Bland-Hawthorn, Joss and Lawrence, J. and Horton, A. J. and Trinh, C. and Leon-Saval, S. G. and Shortridge, K. and Bryant, J. and Case, S. and Colless, M. and Couch, W. and Freeman, K. and Gers, L. and Glazebrook, K. and Haynes, R. and Lee, S. and L{\"o}hmannsr{\"o}ben, Hans-Gerd and O'Byrne, J. and Miziarski, S. and Roth, M. and Schmidt, B. and Tinney, C. G. and Zheng, J.}, title = {Suppression of the near-infrared OH night-sky lines with fibre Bragg gratings - first results}, series = {Monthly notices of the Royal Astronomical Society}, volume = {425}, journal = {Monthly notices of the Royal Astronomical Society}, number = {3}, publisher = {Wiley-Blackwell}, address = {Hoboken}, issn = {0035-8711}, doi = {10.1111/j.1365-2966.2012.21602.x}, pages = {1682 -- 1695}, year = {2012}, abstract = {The background noise between 1 and 1.8 ?mu m in ground-based instruments is dominated by atmospheric emission from hydroxyl molecules. We have built and commissioned a new instrument, the Gemini Near-infrared OH Suppression Integral Field Unit (IFU) System (GNOSIS), which suppresses 103 OH doublets between 1.47 and 1.7?mu m by a factor of 1000 with a resolving power of 10?000. We present the first results from the commissioning of GNOSIS using the IRIS2 spectrograph at the Anglo-Australian Telescope. We present measurements of sensitivity, background and throughput. The combined throughput of the GNOSIS fore-optics, grating unit and relay optics is 36?per cent, but this could be improved to 46?per cent with a more optimal design. We measure strong suppression of the OH lines, confirming that OH suppression with fibre Bragg gratings will be a powerful technology for low-resolution spectroscopy. The integrated OH suppressed background between 1.5 and 1.7 mu m is reduced by a factor of 9 compared to a control spectrum using the same system without suppression. The potential of low-resolution OH-suppressed spectroscopy is illustrated with example observations of Seyfert galaxies and a low-mass star. The GNOSIS background is dominated by detector dark current below 1.67 mu m and by thermal emission above 1.67 mu m. After subtracting these, we detect an unidentified residual interline component of 860 +/- 210 photons s-1 m-2?arcsec-2?mu m-1, comparable to previous measurements. This component is equally bright in the suppressed and control spectra. We have investigated the possible source of the interline component, but were unable to discriminate between a possible instrumental artefact and intrinsic atmospheric emission. Resolving the source of this emission is crucial for the design of fully optimized OH suppression spectrographs. The next-generation OH suppression spectrograph will be focused on resolving the source of the interline component, taking advantage of better optimization for a fibre Bragg grating feed incorporating refinements of design based on our findings from GNOSIS. We quantify the necessary improvements for an optimal OH suppressing fibre spectrograph design.}, language = {en} } @article{ZuehlkeZenichowskiRiebeetal.2017, author = {Z{\"u}hlke, Martin and Zenichowski, Karl and Riebe, Daniel and Beitz, Toralf and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {Subambient pressure electrospray ionization ion mobility spectrometry}, series = {International journal for ion mobility spectrometry : official publication of the International Society for Ion Mobility Spectrometry}, volume = {20}, journal = {International journal for ion mobility spectrometry : official publication of the International Society for Ion Mobility Spectrometry}, publisher = {Springer}, address = {Heidelberg}, issn = {1435-6163}, doi = {10.1007/s12127-017-0215-x}, pages = {47 -- 56}, year = {2017}, abstract = {The pressure dependence of sheath gas assisted electrospray ionization (ESI) was investigated based on two complementary experimental setups, namely an ESI-ion mobility (IM) spectrometer and an ESI capillary - Faraday plate setup housed in an optically accessible vacuum chamber. The ESI-IM spectrometer is capable of working in the pressure range between 300 and 1000 mbar. Another aim was the assessment of the analytical capabilities of a subambient pressure ESI-IM spectrometer. The pressure dependence of ESI was characterized by imaging the electrospray and recording current-voltage (I-U) curves. Qualitatively different behavior was observed in both setups. While the current rises continuously with the voltage in the capillary-plate setup, a sharp increase of the current was measured in the IM spectrometer above a pressure-dependent threshold voltage. The different character can be attributed to the detection of different species in both experiments. In the capillary-plate experiment, a multitude of charged species are detected while only desolvated ions attribute to the IM spectrometer signal. This finding demonstrates the utility of IM spectrometry for the characterization of ESI, since in contrast to the capillary-plate setup, the release of ions from the electrospray droplets can be observed. The I-U curves change significantly with pressure. An important result is the reduction of the maximum current with decreasing pressure. The connected loss of ionization efficiency can be compensated by a more efficient transfer of ions in the IM spectrometer at increased E/N. Thus, similar limits of detection could be obtained at 500 mbar and 1 bar.}, language = {en} } @article{KhademHilleLoehmannsroebenetal.2017, author = {Khadem, S. M. J. and Hille, Carsten and L{\"o}hmannsr{\"o}ben, Hans-Gerd and Sokolov, Igor M.}, title = {Spot variation fluorescence correlation spectroscopy by data post-processing}, series = {Scientific reports}, volume = {7}, journal = {Scientific reports}, publisher = {Nature Publ. Group}, address = {London}, issn = {2045-2322}, doi = {10.1038/s41598-017-05672-8}, pages = {1 -- 9}, year = {2017}, abstract = {Spot variation fluorescence correlation spectroscopy (SV-FCS) is a variant of the FCS techniques which may give useful information about the structural organisation of the medium in which the diffusion takes place. We show that the same results can be obtained by post-processing the photon count data from ordinary FCS measurements. By using this method, one obtains the fluorescence autocorrelation functions for sizes of confocal volume, which are effectively smaller than that of the initial FCS measurement. The photon counts of the initial experiment are first transformed into smooth intensity trace using kernel smoothing method or to a piecewise-continuous intensity trace using binning and then a non-linear transformation is applied to this trace. The result of this transformation mimics the photon count rate in an experiment performed with a smaller confocal volume. The applicability of the method is established in extensive numerical simulations and directly supported in in-vitro experiments. The procedure is then applied to the diffusion of AlexaFluor647-labeled streptavidin in living cells.}, language = {en} } @article{KumkeDoscheFlehretal.2006, author = {Kumke, Michael Uwe and Dosche, Carsten and Flehr, Roman and Trowitzsch-Kienast, Wolfram and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {Spectroscopic characterization of the artificial siderophore pyridinochelin}, issn = {0939-5075}, year = {2006}, language = {en} } @article{ErlerRiebeBeitzetal.2020, author = {Erler, Alexander and Riebe, Daniel and Beitz, Toralf and L{\"o}hmannsr{\"o}ben, Hans-Gerd and Gebbers, Robin}, title = {Soil Nutrient Detection for Precision Agriculture Using Handheld Laser-Induced Breakdown Spectroscopy (LIBS) and Multivariate Regression Methods (PLSR, Lasso and GPR)}, series = {Sensors}, volume = {20}, journal = {Sensors}, number = {2}, publisher = {MDPI}, address = {Basel}, issn = {1424-8220}, doi = {10.3390/s20020418}, pages = {17}, year = {2020}, abstract = {Precision agriculture (PA) strongly relies on spatially differentiated sensor information. Handheld instruments based on laser-induced breakdown spectroscopy (LIBS) are a promising sensor technique for the in-field determination of various soil parameters. In this work, the potential of handheld LIBS for the determination of the total mass fractions of the major nutrients Ca, K, Mg, N, P and the trace nutrients Mn, Fe was evaluated. Additionally, other soil parameters, such as humus content, soil pH value and plant available P content, were determined. Since the quantification of nutrients by LIBS depends strongly on the soil matrix, various multivariate regression methods were used for calibration and prediction. These include partial least squares regression (PLSR), least absolute shrinkage and selection operator regression (Lasso), and Gaussian process regression (GPR). The best prediction results were obtained for Ca, K, Mg and Fe. The coefficients of determination obtained for other nutrients were smaller. This is due to much lower concentrations in the case of Mn, while the low number of lines and very weak intensities are the reason for the deviation of N and P. Soil parameters that are not directly related to one element, such as pH, could also be predicted. Lasso and GPR yielded slightly better results than PLSR. Additionally, several methods of data pretreatment were investigated.}, language = {en} } @misc{ErlerRiebeBeitzetal.2019, author = {Erler, Alexander and Riebe, Daniel and Beitz, Toralf and L{\"o}hmannsr{\"o}ben, Hans-Gerd and Gebbers, Robin}, title = {Soil Nutrient Detection for Precision Agriculture Using Handheld Laser-Induced Breakdown Spectroscopy (LIBS) and Multivariate Regression Methods (PLSR, Lasso and GPR)}, series = {Postprints der Universit{\"a}t Potsdam : Mathematisch-Naturwissenschaftliche Reihe}, journal = {Postprints der Universit{\"a}t Potsdam : Mathematisch-Naturwissenschaftliche Reihe}, number = {815}, issn = {1866-8372}, doi = {10.25932/publishup-44418}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus4-444183}, pages = {19}, year = {2019}, abstract = {Precision agriculture (PA) strongly relies on spatially differentiated sensor information. Handheld instruments based on laser-induced breakdown spectroscopy (LIBS) are a promising sensor technique for the in-field determination of various soil parameters. In this work, the potential of handheld LIBS for the determination of the total mass fractions of the major nutrients Ca, K, Mg, N, P and the trace nutrients Mn, Fe was evaluated. Additionally, other soil parameters, such as humus content, soil pH value and plant available P content, were determined. Since the quantification of nutrients by LIBS depends strongly on the soil matrix, various multivariate regression methods were used for calibration and prediction. These include partial least squares regression (PLSR), least absolute shrinkage and selection operator regression (Lasso), and Gaussian process regression (GPR). The best prediction results were obtained for Ca, K, Mg and Fe. The coefficients of determination obtained for other nutrients were smaller. This is due to much lower concentrations in the case of Mn, while the low number of lines and very weak intensities are the reason for the deviation of N and P. Soil parameters that are not directly related to one element, such as pH, could also be predicted. Lasso and GPR yielded slightly better results than PLSR. Additionally, several methods of data pretreatment were investigated.}, language = {en} } @article{GeisslerStuflerLoehmannsroebenetal.2013, author = {Geissler, Daniel and Stufler, Stefan and L{\"o}hmannsr{\"o}ben, Hans-Gerd and Hildebrandt, Niko}, title = {Six-color time-resolved forster resonance energy transfer for ultrasensitive multiplexed biosensing}, series = {Journal of the American Chemical Society}, volume = {135}, journal = {Journal of the American Chemical Society}, number = {3}, publisher = {American Chemical Society}, address = {Washington}, issn = {0002-7863}, doi = {10.1021/ja310317n}, pages = {1102 -- 1109}, year = {2013}, abstract = {Simultaneous monitoring of multiple molecular interactions and multiplexed detection of several diagnostic biomarkers at very low concentrations have become important issues in advanced biological and chemical sensing. Here we present an optically multiplexed six-color Forster resonance energy transfer (FRET) biosensor for simultaneous monitoring of five different individual binding events. We combined simultaneous FRET from one Tb complex to five different organic dyes measured in a filter-based time-resolved detection format with a sophisticated spectral crosstalk correction, which results in very efficient background suppression. The advantages and robustness of the multiplexed FRET sensor were exemplified by analyzing a 15-component lung cancer immunoassay involving 10 different antibodies and five different tumor markers in a single 50 mu L human serum sample. The multiplexed biosensor offers clinically relevant detection limits in the low picomolar (ng/mL) concentration range for all five markers, thus providing an effective early screening tool for lung cancer with the possibility of distinguishing small-cell from non-small-cell lung carcinoma. This novel technology will open new doors for multiple biomarker diagnostics as well as multiplexed real-time imaging and spectroscopy.}, language = {en} } @article{CywinskiMoroRitscheletal.2011, author = {Cywinski, Piotr J. and Moro, Artur J. and Ritschel, Thomas and Hildebrandt, Niko and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {Sensitive and selective fluorescence detection of guanosine nucleotides by nanoparticles conjugated with a naphthyridine receptor}, series = {Analytical \& bioanalytical chemistry}, volume = {399}, journal = {Analytical \& bioanalytical chemistry}, number = {3}, publisher = {Springer}, address = {Heidelberg}, issn = {1618-2642}, doi = {10.1007/s00216-010-4420-2}, pages = {1215 -- 1222}, year = {2011}, abstract = {Novel fluorescent nanosensors, based on a naphthyridine receptor, have been developed for the detection of guanosine nucleotides, and both their sensitivity and selectivity to various nucleotides were evaluated. The nanosensors were constructed from polystyrene nanoparticles functionalized by (N-(7-((3-aminophenyl) ethynyl)-1,8-naphthyridin- 2-yl) acetamide) via carbodiimide ester activation. We show that this naphthyridine nanosensor binds guanosine nucleotides preferentially over adenine, cytosine, and thymidine nucleotides. Upon interaction with nucleotides, the fluorescence of the nanosensor is gradually quenched yielding Stern-Volmer constants in the range of 2.1 to 35.9mM(-1). For all the studied quenchers, limits of detection (LOD) and tolerance levels for the nanosensors were also determined. The lowest (3 sigma) LOD was found for guanosine 3',5'-cyclic monophosphate (cGMP) and it was as low as 150 ng/ml. In addition, we demonstrated that the spatial arrangement of bound analytes on the nanosensors' surfaces is what is responsible for their selectivity to different guanosine nucleotides. We found a correlation between the changes of the fluorescence signal and the number of phosphate groups of a nucleotide. Results of molecular modeling and zeta-potential measurements confirm that the arrangement of analytes on the surface provides for the selectivity of the nanosensors. These fluorescent nanosensors have the potential to be applied in multi-analyte, array-based detection platforms, as well as in multiplexed microfluidic systems.}, language = {en} } @article{ZuehlkeSassRiebeetal.2017, author = {Z{\"u}hlke, Martin and Sass, Stephan and Riebe, Daniel and Beitz, Toralf and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {Real-Time Reaction Monitoring of an Organic Multistep Reaction by Electrospray Ionization-Ion Mobility Spectrometry}, series = {ChemPlusChem}, volume = {82}, journal = {ChemPlusChem}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {2192-6506}, doi = {10.1002/cplu.201700296}, pages = {1266 -- 1273}, year = {2017}, abstract = {The capability of electrospray ionization (ESI)-ion mobility (IM) spectrometry for reaction monitoring is assessed both as a stand-alone real-time technique and in combination with HPLC. A three-step chemical reaction, consisting of a Williamson ether synthesis followed by a hydrogenation and an N-alkylation step, is chosen for demonstration. Intermediates and products are determined with a drift time to mass-per-charge correlation. Addition of an HPLC column to the setup increases the separation power and allows the determination of further species. Monitoring of the intensities of the various species over the reaction time allows the detection of the end of reaction, determination of the rate-limiting step, observation of the system response in discontinuous processes, and optimization of the mass ratios of the starting materials. However, charge competition in ESI influences the quantitative detection of substances in the reaction mixture. Therefore, two different methods are investigated, which allow the quantification and investigation of reaction kinetics. The first method is based on the pre-separation of the compounds on an HPLC column and their subsequent individual detection in the ESI-IM spectrometer. The second method involves an extended calibration procedure, which considers charge competition effects and facilitates nearly real-time quantification.}, language = {en} } @misc{HildebrandtCharbonniereZiesseletal.2006, author = {Hildebrandt, Nico and Charbonni{\`e}re, Lo{\"i}c J. and Ziessel, Raymond F. and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {Quantum dots as resonance energy transfer acceptors for monitoring biological interactions}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus-12213}, year = {2006}, abstract = {Quantum dots (QDs) are common as luminescing markers for imaging in biological applications because their optical properties seem to be inert against their surrounding solvent. This, together with broad and strong absorption bands and intense, sharp tuneable luminescence bands, makes them interesting candidates for methods utilizing Forster Resonance Energy Transfer (FRET), e. g. for sensitive homogeneous fluoroimmunoassays (FIA). In this work we demonstrate energy transfer from Eu3+-trisbipyridin (Eu-TBP) donors to CdSe-ZnS-QD acceptors in solutions with and without serum. The QDs are commercially available CdSe-ZnS core-shell particles emitting at 655 nm (QD655). The FRET system was achieved by the binding of the streptavidin conjugated donors with the biotin conjugated acceptors. After excitation of Eu-TBP and as result of the energy transfer, the luminescence of the QD655 acceptors also showed lengthened decay times like the donors. The energy transfer efficiency, as calculated from the decay times of the bound and the unbound components, amounted to 37\%. The Forster-radius, estimated from the absorption and emission bands, was ca. 77{\AA}. The effective binding ratio, which not only depends on the ratio of binding pairs but also on unspecific binding, was obtained from the donor emission dependent on the concentration. As serum promotes unspecific binding, the overall FRET efficiency of the assay was reduced. We conclude that QDs are good substitutes for acceptors in FRET if combined with slow decay donors like Europium. The investigation of the influence of the serum provides guidance towards improving binding properties of QD assays.}, language = {en} } @article{GeisslerCharbonniereZiesseletal.2009, author = {Geißler, Daniel and Charbonni{\`e}re, Lo{\"i}c J. and Ziessel, Raymond F. and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {Quantum dots as FRET acceptors for highly sensitive multiplexing immunoassays}, year = {2009}, language = {en} } @article{HildebrandtCharbonniereBecketal.2005, author = {Hildebrandt, Niko and Charbonniere, Lo{\"i}c J. and Beck, Michael and Ziessel, Raymond F. and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {Quantum dots as efficient energy acceptors in a time-resolved fluoroimmunoassay}, issn = {1433-7851}, year = {2005}, language = {en} }