@article{EngelMuellerKopinskietal.2017, author = {Engel, Tilman and Mueller, Juliane and Kopinski, Stephan and Reschke, Antje and Mueller, Steffen and Mayer, Frank}, title = {Unexpected walking perturbations: Reliability and validity of a new treadmill protocol to provoke muscular reflex activities at lower extremities and the trunk}, series = {Journal of biomechanics}, volume = {55}, journal = {Journal of biomechanics}, publisher = {Elsevier}, address = {Oxford}, issn = {0021-9290}, doi = {10.1016/j.jbiomech.2017.02.026}, pages = {152 -- 155}, year = {2017}, abstract = {Instrumented treadmills offer the potential to generate standardized walking perturbations, which are particularly rapid and powerful. However, technical requirements to release adequate perturbations regarding timing, duration and amplitude are demanding. This study investigated the test-retest reliability and validity of a new treadmill perturbation protocol releasing rapid and unexpected belt perturbations to provoke muscular reflex responses at lower extremities and the trunk. Fourteen healthy participants underwent two identical treadmill walking protocols, consisting of 10 superimposed one-sided belt perturbations (100 ms duration; 2 m/s amplitude), triggered by a plantar pressure insole 200 ms after heel contact. Delay, duration and amplitude of applied perturbations were recorded by 3D-motion capture. Muscular reflex responses (within 200 ms) were measured at lower extremities and the trunk (10-lead EMG). Data was analyzed descriptively (mean +/- SD). Reliability was analyzed using test-retest variability (TRV\%) and limits of agreement (LoA, bias +/- 1.96*SD). Perturbation delay was 202 14 ms, duration was 102 +/- 4 ms and amplitude was 2.1 +/- 0.01 m/s. TRV for perturbation delay, duration and amplitude ranged from 5.0\% to 5.7\%. LoA reached 3 +/- 36 ms for delay, 2 +/- 13 ms for duration and 0.0 +/- 0.3 m/s for amplitude. EMG amplitudes following perturbations ranged between 106 +/- 97\% and 909 +/- 979\% of unperturbed gait and EMG latencies between 82 +/- 14 ms and 106 +/- 16 ms. Minor differences between preset and observed perturbation characteristics and results of test-retest analysis prove a high validity with excellent reliability of the setup. Therefore, the protocol tested can be recommended to provoke muscular reflex responses at lower extremities and the trunk in perturbed walking. (C) 2017 Elsevier Ltd. All rights reserved.}, language = {en} } @article{MuellerStollCasseletal.2017, author = {M{\"u}ller, Steffen and Stoll, Josefine and Cassel, Michael and Mayer, Frank}, title = {Trunk Muscle Activity during Drop Jump Performance in Adolescent Athletes with Back Pain}, series = {Frontiers in physiology}, volume = {8}, journal = {Frontiers in physiology}, publisher = {Frontiers Research Foundation}, address = {Lausanne}, issn = {1664-042X}, doi = {10.3389/fphys.2017.00274}, year = {2017}, abstract = {In the context of back pain, great emphasis has been placed on the importance of trunk stability, especially in situations requiring compensation of repetitive, intense loading induced during high-performance activities, e.g., jumping or landing. This study aims to evaluate trunk muscle activity during drop jump in adolescent athletes with back pain (BP) compared to athletes without back pain (NBP). Eleven adolescent athletes suffering back pain (BP: m/f: n = 4/7; 15.9 ± 1.3 y; 176 ± 11 cm; 68 ± 11 kg; 12.4 ± 10.5 h/we training) and 11 matched athletes without back pain (NBP: m/f: n = 4/7; 15.5 ± 1.3 y; 174 ± 7 cm; 67 ± 8 kg; 14.9 ± 9.5 h/we training) were evaluated. Subjects conducted 3 drop jumps onto a force plate (ground reaction force). Bilateral 12-lead SEMG (surface Electromyography) was applied to assess trunk muscle activity. Ground contact time [ms], maximum vertical jump force [N], jump time [ms] and the jump performance index [m/s] were calculated for drop jumps. SEMG amplitudes (RMS: root mean square [\%]) for all 12 single muscles were normalized to MIVC (maximum isometric voluntary contraction) and analyzed in 4 time windows (100 ms pre- and 200 ms post-initial ground contact, 100 ms pre- and 200 ms post-landing) as outcome variables. In addition, muscles were grouped and analyzed in ventral and dorsal muscles, as well as straight and transverse trunk muscles. Drop jump ground reaction force variables did not differ between NBP and BP (p > 0.05). Mm obliquus externus and internus abdominis presented higher SEMG amplitudes (1.3-1.9-fold) for BP (p < 0.05). Mm rectus abdominis, erector spinae thoracic/lumbar and latissimus dorsi did not differ (p > 0.05). The muscle group analysis over the whole jumping cycle showed statistically significantly higher SEMG amplitudes for BP in the ventral (p = 0.031) and transverse muscles (p = 0.020) compared to NBP. Higher activity of transverse, but not straight, trunk muscles might indicate a specific compensation strategy to support trunk stability in athletes with back pain during drop jumps. Therefore, exercises favoring the transverse trunk muscles could be recommended for back pain treatment.}, language = {en} } @article{MuellerStollMuelleretal.2017, author = {M{\"u}ller, Steffen and Stoll, Josefine and Mueller, Juliane and Cassel, Michael and Mayer, Frank}, title = {Trunk Muscle Activity during Drop Jump Performance in Adolescent Athletes with Back Pain}, series = {Frontiers in physiology}, volume = {8}, journal = {Frontiers in physiology}, publisher = {Frontiers Research Foundation}, address = {Lausanne}, issn = {1664-042X}, doi = {10.3389/fphys.2017.00274}, pages = {124 -- 132}, year = {2017}, abstract = {In the context of back pain, great emphasis has been placed on the importance of trunk stability, especially in situations requiring compensation of repetitive, intense loading induced during high-performance activities, e.g., jumping or landing. This study aims to evaluate trunk muscle activity during drop jump in adolescent athletes with back pain (BP) compared to athletes without back pain (NBP). Eleven adolescent athletes suffering back pain (BP: m/f: n = 4/7; 15.9 +/- 1.3 y; 176 +/- 11 cm; 68 +/- 11 kg; 12.4 +/- 10.5 h/we training) and 11 matched athletes without back pain (NBP: m/f: n = 4/7; 15.5 +/- 1.3 y; 174 +/- 7 cm; 67 +/- 8 kg; 14.9 +/- 9.5 h/we training) were evaluated. Subjects conducted 3 drop jumps onto a force plate (ground reaction force). Bilateral 12-lead SEMG (surface Electromyography) was applied to assess trunk muscle activity. Ground contact time [ms], maximum vertical jump force [N], jump time [ms] and the jump performance index [m/s] were calculated for drop jumps. SEMG amplitudes (RMS: root mean square [\%]) for all 12 single muscles were normalized toMIVC (maximum isometric voluntary contraction) and analyzed in 4 time windows (100 ms pre- and 200 ms post-initial ground contact, 100 ms pre- and 200 ms post-landing) as outcome variables. In addition, muscles were grouped and analyzed in ventral and dorsal muscles, as well as straight and transverse trunk muscles. Drop jump ground reaction force variables did not differ between NBP and BP (p > 0.05). Mm obliquus externus and internus abdominis presented higher SEMG amplitudes (1.3-1.9-fold) for BP (p < 0.05). Mm rectus abdominis, erector spinae thoracic/lumbar and latissimus dorsi did not differ (p > 0.05). The muscle group analysis over the whole jumping cycle showed statistically significantly higher SEMG amplitudes for BP in the ventral (p = 0.031) and transverse muscles (p = 0.020) compared to NBP. Higher activity of transverse, but not straight, trunk muscles might indicate a specific compensation strategy to support trunk stability in athletes with back pain during drop jumps. Therefore, exercises favoring the transverse trunk muscles could be recommended for back pain treatment.}, language = {en} } @article{MartinezValdesNegroLaineetal.2017, author = {Martinez-Valdes, Eduardo Andr{\´e}s and Negro, F. and Laine, C. M. and Falla, D. and Mayer, Frank and Farina, Dario}, title = {Tracking motor units longitudinally across experimental sessions with high-density surface electromyography}, series = {The Journal of Physiology}, volume = {595}, journal = {The Journal of Physiology}, publisher = {Wiley}, address = {Hoboken}, issn = {0022-3751}, doi = {10.1113/JP273662}, pages = {1479 -- 1496}, year = {2017}, abstract = {A new method is proposed for tracking individual motor units (MUs) across multiple experimental sessions on different days. The technique is based on a novel decomposition approach for high-density surface electromyography and was tested with two experimental studies for reliability and sensitivity. Experiment I (reliability): ten participants performed isometric knee extensions at 10, 30, 50 and 70\% of their maximum voluntary contraction (MVC) force in three sessions, each separated by 1 week. Experiment II (sensitivity): seven participants performed 2 weeks of endurance training (cycling) and were tested pre-post intervention during isometric knee extensions at 10 and 30\% MVC. The reliability (Experiment I) and sensitivity (Experiment II) of the measured MU properties were compared for the MUs tracked across sessions, with respect to all MUs identified in each session. In Experiment I, on average 38.3\% and 40.1\% of the identified MUs could be tracked across two sessions (1 and 2 weeks apart), for the vastus medialis and vastus lateralis, respectively. Moreover, the properties of the tracked MUs were more reliable across sessions than those of the full set of identified MUs (intra-class correlation coefficients ranged between 0.63-0.99 and 0.39-0.95, respectively). In Experiment II, similar to 40\% of the MUs could be tracked before and after the training intervention and training-induced changes in MU conduction velocity had an effect size of 2.1 (tracked MUs) and 1.5 (group of all identified motor units). These results show the possibility of monitoring MU properties longitudinally to document the effect of interventions or the progression of neuromuscular disorders.}, language = {en} } @misc{DeWittHubertsNiedererWippertetal.2017, author = {De Witt Huberts, Jessie and Niederer, Daniel and Wippert, Pia-Maria and Mayer, Frank}, title = {The effects of a new practical and synergetic multimodal treatment for chronic back pain on pain-related cognitions and wellbeing}, series = {Psychosomatic medicine}, volume = {79}, journal = {Psychosomatic medicine}, number = {4}, publisher = {Lippincott Williams \& Wilkins}, address = {Philadelphia}, issn = {0033-3174}, pages = {A22 -- A23}, year = {2017}, language = {en} } @article{WochatzRabeWolteretal.2017, author = {Wochatz, Monique and Rabe, Sophie and Wolter, Martin and Engel, Tilman and Mueller, Steffen and Mayer, Frank}, title = {Reproducibility of scapular muscle activity in isokinetic shoulder flexion and extension}, series = {Journal of electromyography and kinesiology}, volume = {34}, journal = {Journal of electromyography and kinesiology}, publisher = {Elsevier}, address = {Oxford}, issn = {1050-6411}, doi = {10.1016/j.jelekin.2017.04.006}, pages = {86 -- 92}, year = {2017}, abstract = {Repetitive overhead movements have been identified as a main risk factor to develop shoulder complaints with scapular muscle activity being altered. Reliable assessment of muscle activity is essential to differentiate between symptomatic and asymptomatic individuals. Therefore, the present study aimed to investigate the intra-and inter-session reliability of scapular muscle activity during maximal isokinetic shoulder flexion and extension. Eleven asymptomatic adults performed maximum effort isokinetic shoulder flexion and extension (concentric and eccentric at 60 degrees/s) in a test-retest design. Muscle activity of the upper and lower trapezius and serratus anterior was assessed by sEMG. Root Mean Square was calculated for whole ROM and single movement phases of absolute and normalized muscle activity. Absolute (Bland-Altman analysis (Bias, LoA), Minimal detectable change (MDC)) and relative reliability parameters (Intraclass correlation coefficient (ICC), coefficient of variation (CV)/test-retest variability (TRV)) were utilized for the evaluation of reproducibility. Intra-session reliability revealed ICCs between 0.56 and 0.98, averaged CVs of 18\% and average MDCs of 81 mV. Inter-session reliability resulted in ICCs between 0.13 and 0.93, averaged TRVs of 21\%, average MDCs of 15\% and systematic and random error between -8 +/- 60\% and 12 +/- 36\%. Scapular muscle activity assessed in overhead movements can be measured reliably under maximum load conditions, though variability is dependent on the movement phase. Measurement variability does not exceed magnitudes of altered scapular muscle activities as reported in previous studies. Therefore, maximum load application is a promising approach for the evaluation of changes in scapular control related to pathologies. (C) 2017 Elsevier Ltd. All rights reserved.}, language = {en} } @article{RectorIntziegianniMuelleretal.2017, author = {Rector, Michael V. and Intziegianni, Konstantina and M{\"u}ller, Steffen and Mayer, Frank and Cassel, Michael}, title = {Reproducibility of an ankle joint rotation correction method for assessment of Achilles tendon elongation}, series = {Isokinetics and exercise science : official journal of the European Isokinetic Society}, volume = {25}, journal = {Isokinetics and exercise science : official journal of the European Isokinetic Society}, number = {1}, publisher = {IOS Press}, address = {Amsterdam}, issn = {0959-3020}, doi = {10.3233/IES-160644}, pages = {47 -- 52}, year = {2017}, abstract = {BACKGROUND: The Achilles tendon (AT) requires optimal material and mechanical properties to function properly. Calculation of these properties depends on accurate measurement of input parameters (i.e. tendon elongation). However, the measurement of AT elongation with ultrasound during maximum voluntary isometric contraction (MVIC) is overestimated by ankle joint rotation (AJR). Methods to correct the influence of this rotation on AT elongation exist, yet their reproducibility in clinical settings is unknown. OBJECTIVE: To evaluate the test-retest reproducibility of AT elongation during MVIC after AJR correction. METHODS: Ten participants attended test and retest measurements where they performed plantar-flexion MVIC on a dynamometer. Simultaneously, ultrasound recorded AT elongation as the displacement of the medial gastrocnemius-myotendinous junction, while an electrogoniometer measured AJR. The ankle was then passively rotated to the AJR achieved during MVIC and AT elongation again determined. Elongation was corrected by subtracting this passive AT elongation from the total AT elongation during MVIC. Reproducibility was evaluated using ICC (2.1), test-retest variability (TRV, \%), Bland-Altman analyses (Bias +/- LoA [1.96*SD]) and standard error of the measurement (SEM). RESULTS: Corrected AT elongation reproducibility exhibited an ICC = 0.79, SEM = 0.2 cm and TRV = 20 +/- 19\%. Bias +/- LoA were determined to be 0.0 +/- 0.8 cm. CONCLUSIONS: Using this ultrasound and electrogoniometer-based method, corrected AT elongation can be assessed reproducibly.}, language = {en} } @article{RischWochatzMesserschmidtetal.2017, author = {Risch, Lucie and Wochatz, Monique and Messerschmidt, Janin and Engel, Tilman and Mayer, Frank and Cassel, Michael}, title = {Reliability of evaluating achilles tendon vascularization assessed with doppler ultrasound advanced dynamic flow}, series = {Journal of ultrasound in medicine}, volume = {37}, journal = {Journal of ultrasound in medicine}, number = {3}, publisher = {Wiley}, address = {Hoboken}, issn = {0278-4297}, doi = {10.1002/jum.14414}, pages = {737 -- 744}, year = {2017}, abstract = {The reliability of quantifying intratendinous vascularization by high-sensitivity Doppler ultrasound advanced dynamic flow has not been examined yet. Therefore, this study aimed to investigate the intraobserver and interobserver reliability of evaluating Achilles tendon vascularization by advanced dynamic flow using established scoring systems. Methods-Three investigators evaluated vascularization in 67 recordings in a test-retest design, applying the Ohberg score, a modified Ohberg score, and a counting score. Intraobserver and interobserver agreement for the Ohberg score and modified Ohberg score was analyzed by the Cohen kappa and Fleiss kappa coefficients (absolute), Kendall tau b coefficient, and Kendall coefficient of concordance (W; relative). The reliability of the counting score was analyzed by intraclass correlation coefficients (ICC) 2.1 and 3.1, the standard error of measurement (SEM), and Bland-Altman analysis (bias and limits of agreement [LoA]). Results-Intraobserver and interobserver agreement (absolute/relative) ranged from 0.61 to 0.87/0.87 to 0.95 and 0.11 to 0.66/0.76 to 0.89 for the Ohberg score and from 0.81 to 0.87/0.92 to 0.95 and 0.64 to 0.80/0.88 to 0.93 for the modified Ohberg score, respectively. The counting score revealed an intraobserver ICC of 0.94 to 0.97 (SEM, 1.0-1.5; bias, -1; and LoA, 3-4 vessels). The interobserver ICC for the counting score ranged from 0.91 to 0.98 (SEM, 1.0-1.9; bias, 0; and LoA, 3-5 vessels). Conclusions-The modified Ohberg score and counting score showed excellent reliability and seem convenient for research and clinical practice. The Ohberg score revealed decent intraobserver but unexpected low interobserver reliability and therefore cannot be recommended.}, language = {en} } @article{CasselIntziegianniRischetal.2017, author = {Cassel, Michael and Intziegianni, Konstantina and Risch, Lucie and Mueller, Steffen and Engel, Tilman and Mayer, Frank}, title = {Physiological Tendon Thickness Adaptation in Adolescent Elite Athletes: A Longitudinal Study}, series = {Frontiers in physiology}, volume = {8}, journal = {Frontiers in physiology}, publisher = {Frontiers Research Foundation}, address = {Lausanne}, issn = {1664-042X}, doi = {10.3389/fphys.2017.00795}, pages = {599 -- 611}, year = {2017}, abstract = {Increased Achilles (AT) and Patellar tendon (PT) thickness in adolescent athletes compared to non-athletes could be shown. However, it is unclear, if changes are of pathological or physiological origin due to training. The aim of this study was to determine physiological AT and PT thickness adaptation in adolescent elite athletes compared to non-athletes, considering sex and sport. In a longitudinal study design with two measurement days (M1/M2) within an interval of 3.2 +/- 0.8 years, 131 healthy adolescent elite athletes (m/f: 90/41) out of 13 different sports and 24 recreationally active controls (m/f: 6/18) were included. Both ATs and PTs were measured at standardized reference points. Athletes were divided into 4 sport categories [ball (B), combat (C), endurance (E) and explosive strength sports (S)]. Descriptive analysis (mean SD) and statistical testing for group differences was performed (cy = 0.05). AT thickness did not differ significantly between measurement days, neither in athletes (5.6 +/- 0.7 mm/5.6 +/- 0.7 mm) nor in controls (4.8 +/- 0.4 mm/4.9 +/- 0.5 mm, p > 0.05). For PTs, athletes presented increased thickness at M2 (Ml: 3.5 +/- 0.5 mm, M2: 3.8 +/- 0.5 mm, p < 0.001). In general, males had thicker ATs and PTs than females (p < 0.05). Considering sex and sports, only male athletes from B, C, and S showed significant higher PT-thickness at M2 compared to controls (p <= 0.01). Sport-specific adaptation regarding tendon thickness in adolescent elite athletes can be detected in PTs among male athletes participating in certain sports with high repetitive jumping and strength components. Sonographic microstructural analysis might provide an enhanced insight into tendon material properties enabling the differentiation of sex and influence of different sports.}, language = {en} } @article{CasselIntziegianniRischetal.2017, author = {Cassel, Michael and Intziegianni, Konstantina and Risch, Lucie and M{\"u}ller, Steffen and Engel, Tilman and Mayer, Frank}, title = {Physiological Tendon Thickness Adaptation in Adolescent Elite Athletes}, series = {Frontiers in physiology}, volume = {8}, journal = {Frontiers in physiology}, publisher = {Frontiers}, address = {Lausanne}, issn = {1664-042X}, doi = {10.3389/fphys.2017.00795}, pages = {1 -- 8}, year = {2017}, abstract = {Increased Achilles (AT) and Patellar tendon (PT) thickness in adolescent athletes compared to non-athletes could be shown. However, it is unclear, if changes are of pathological or physiological origin due to training. The aim of this study was to determine physiological AT and PT thickness adaptation in adolescent elite athletes compared to non-athletes, considering sex and sport. In a longitudinal study design with two measurement days (M1/M2) within an interval of 3.2 ± 0.8 years, 131 healthy adolescent elite athletes (m/f: 90/41) out of 13 different sports and 24 recreationally active controls (m/f: 6/18) were included. Both ATs and PTs were measured at standardized reference points. Athletes were divided into 4 sport categories [ball (B), combat (C), endurance (E) and explosive strength sports (S)]. Descriptive analysis (mean ± SD) and statistical testing for group differences was performed (α = 0.05). AT thickness did not differ significantly between measurement days, neither in athletes (5.6 ± 0.7 mm/5.6 ± 0.7 mm) nor in controls (4.8 ± 0.4 mm/4.9 ± 0.5 mm, p > 0.05). For PTs, athletes presented increased thickness at M2 (M1: 3.5 ± 0.5 mm, M2: 3.8 ± 0.5 mm, p < 0.001). In general, males had thicker ATs and PTs than females (p < 0.05). Considering sex and sports, only male athletes from B, C, and S showed significant higher PT-thickness at M2 compared to controls (p ≤ 0.01). Sport-specific adaptation regarding tendon thickness in adolescent elite athletes can be detected in PTs among male athletes participating in certain sports with high repetitive jumping and strength components. Sonographic microstructural analysis might provide an enhanced insight into tendon material properties enabling the differentiation of sex and influence of different sports.}, language = {en} }