@article{GeisslerCharbonniereZiesseletal.2010, author = {Geißler, Daniel and Charbonni{\`e}re, Lo{\"i}c J. and Ziessel, Raymond F. and Butlin, Nathaniel G. and L{\"o}hmannsr{\"o}ben, Hans-Gerd and Hildebrandt, Niko}, title = {Quantum dot biosensors for ultrasensitive multiplexed diagnostics}, issn = {1433-7851}, doi = {10.1002/anie.200906399}, year = {2010}, abstract = {Time- and color-resolved detection of Foerster resonance energy transfer (FRET) from luminescent terbium complexes to different semiconductor quantum dots results in a fivefold multiplexed bioassay with sub-picomolar detection limits for all five bioanalytes (see picture). The detection of up to five biomarkers occurs with a sensitivity that is 40-240-fold higher than one of the best-established single-analyte reference assays.}, language = {en} } @article{KadjaneStarckCamereletal.2009, author = {Kadjane, Pascal and Starck, Matthieu and Camerel, Franck and Hill, Diana and Hildebrandt, Niko and Ziessel, Raymond and Charbonni{\`e}re, Lo{\"i}c J.}, title = {Divergent approach to a large variety of versatile luminescent lanthanide complexes}, issn = {0020-1669}, doi = {10.1021/Ic9001169}, year = {2009}, abstract = {Using a regioselective strategy for nucleophilic aromatic substitution on polyfluoropyridines, a nonacoordinating precursor was designed that is adequately suited for complexation of lanthanide cations. Further functionalizations afforded numerous applications for near-IR emission, two-photon absorption spectroscopy, or the formation of luminescent gels.}, language = {en} } @article{GeisslerCharbonniereZiesseletal.2009, author = {Geißler, Daniel and Charbonni{\`e}re, Lo{\"i}c J. and Ziessel, Raymond F. and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {Quantum dots as FRET acceptors for highly sensitive multiplexing immunoassays}, year = {2009}, language = {en} } @misc{CywińskiNonoCharbonniereetal.2014, author = {Cywiński, Piotr J. and Nono, Katia Nchimi and Charbonni{\`e}re, Lo{\"i}c J. and Hammann, Tommy and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {Photophysical evaluation of a new functional terbium complex in FRET-based time-resolved homogenous fluoroassays}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus4-95390}, pages = {6060 -- 6067}, year = {2014}, abstract = {A new functional luminescent lanthanide complex (LLC) has been synthesized with terbium as a central lanthanide ion and biotin as a functional moiety. Unlike in typical lanthanide complexes assembled via carboxylic moieties, in the presented complex, four phosphate groups are chelating the central lanthanide ion. This special chemical assembly enhances the complex stability in phosphate buffers conventionally used in biochemistry. The complex synthesis strategy and photophysical properties are described as well as the performance in time-resolved F{\"o}rster Resonance Energy Transfer (FRET) assays. In those assays, this biotin-LLC transferred energy either to acceptor organic dyes (Cy5 or AF680) labelled on streptavidin or to quantum dots (QD655 or QD705) surface-functionalised with streptavidins. The permanent spatial donor-acceptor proximity is assured through strong and stable biotin-streptavidin binding. The energy transfer is evidenced from the quenching observed in donor emission and from a decrease in donor luminescence decay, both associated with simultaneous increase in acceptor intensity and in the decay time. The dye-based assays are realised in TRIS and in PBS, whereas QD-based systems are studied in borate buffer. The delayed emission analysis allows for quantifying the recognition process and for auto-fluorescence-free detection, which is particularly relevant for application in bioanalysis. In accordance with F{\"o}rster theory, F{\"o}rster-radii (R0) were found to be around 60 {\AA} for organic dyes and around 105 {\AA} for QDs. The FRET efficiency (η) reached 80\% and 25\% for dye and QD acceptors, respectively. Physical donor-acceptor distances (r) have been determined in the range 45-60 {\AA} for organic dye acceptors, while for acceptor QDs between 120 {\AA} and 145 {\AA}. This newly synthesised biotin-LLC extends the class of highly sensitive analytical tools to be applied in the bioanalytical methods such as time-resolved fluoroimmunoassays (TR-FIA), luminescent imaging and biosensing.}, language = {en} } @misc{HildebrandtCharbonniereZiesseletal.2006, author = {Hildebrandt, Nico and Charbonni{\`e}re, Lo{\"i}c J. and Ziessel, Raymond F. and L{\"o}hmannsr{\"o}ben, Hans-Gerd}, title = {Quantum dots as resonance energy transfer acceptors for monitoring biological interactions}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus-12213}, year = {2006}, abstract = {Quantum dots (QDs) are common as luminescing markers for imaging in biological applications because their optical properties seem to be inert against their surrounding solvent. This, together with broad and strong absorption bands and intense, sharp tuneable luminescence bands, makes them interesting candidates for methods utilizing Forster Resonance Energy Transfer (FRET), e. g. for sensitive homogeneous fluoroimmunoassays (FIA). In this work we demonstrate energy transfer from Eu3+-trisbipyridin (Eu-TBP) donors to CdSe-ZnS-QD acceptors in solutions with and without serum. The QDs are commercially available CdSe-ZnS core-shell particles emitting at 655 nm (QD655). The FRET system was achieved by the binding of the streptavidin conjugated donors with the biotin conjugated acceptors. After excitation of Eu-TBP and as result of the energy transfer, the luminescence of the QD655 acceptors also showed lengthened decay times like the donors. The energy transfer efficiency, as calculated from the decay times of the bound and the unbound components, amounted to 37\%. The Forster-radius, estimated from the absorption and emission bands, was ca. 77{\AA}. The effective binding ratio, which not only depends on the ratio of binding pairs but also on unspecific binding, was obtained from the donor emission dependent on the concentration. As serum promotes unspecific binding, the overall FRET efficiency of the assay was reduced. We conclude that QDs are good substitutes for acceptors in FRET if combined with slow decay donors like Europium. The investigation of the influence of the serum provides guidance towards improving binding properties of QD assays.}, language = {en} }