@article{BaurHirschmuellerMuelleretal.2012, author = {Baur, Heiner and Hirschm{\"u}ller, Anja and M{\"u}ller, Steffen and Cassel, Michael and Mayer, Frank}, title = {Is EMG of the lower leg dependent on weekly running mileage?}, series = {International journal of sports medicine}, volume = {33}, journal = {International journal of sports medicine}, number = {1}, publisher = {Thieme}, address = {Stuttgart}, issn = {0172-4622}, doi = {10.1055/s-0031-1286250}, pages = {53 -- 57}, year = {2012}, abstract = {Neuromuscular activity of the lower leg is dependent on the task performed, speed of movement and gender. Whether training volume influences neuromuscular activity is not known. The EMG of physically active persons differing in running mileage was analysed to investigate this. 55 volunteers were allocated to a low (LM: < 30 km), intermediate (IM: > 30 km \& < 45 km) or high mileage (HM: > 45 km) group according to their weekly running volume. Neuromuscular activity of the lower leg was measured during running (3.33 m.s(-1)). Mean amplitude values for preactivation, weight acceptance and push-off were calculated and normalised to the mean activity of the entire gait cycle. Higher activity in the gastrocnemius group was observed in weight acceptance in LM compared to IM (+30\%) and HM (+25\%) but lower activity was present in the push-off for LM compared to IM and HM. For the peroneal muscle, differences were present in the push-off where HM showed increased activity compared to IM (+24\%) and LM (+60\%). The tibial muscle revealed slightly lower activity during preactivation for the high mileage runners. Neuromuscular activity differs during stance between the high and intermediate group compared to low mileage runners. Slight adaptations in neuromuscular activation indicate a more target-oriented activation strategy possibly due to repetitive training in runners with higher weekly mileage.}, language = {en} } @unpublished{BaurHoffmannReichmuthetal.2012, author = {Baur, Heiner and Hoffmann, Jan and Reichmuth, Anne and M{\"u}ller, Steffen and Mayer, Frank}, title = {Influence of carbon fiber foot orthoses on plantar pressure distribution in cycling}, series = {Sportverletzung, Sportschaden : Grundlagen, Pr{\"a}vention, Rehabilitation}, volume = {26}, journal = {Sportverletzung, Sportschaden : Grundlagen, Pr{\"a}vention, Rehabilitation}, number = {1}, publisher = {Thieme}, address = {Stuttgart}, issn = {0932-0555}, pages = {12 -- 17}, year = {2012}, abstract = {Background: Several equipment interventions like optimizing seat position or optimizing shoe/insole/pedal interface are suggested to reduce overuse injury in cycling. Data analyzing clinical or biomechanical effects of those interventions is sparse. Foot orthoses out of carbon fiber are one possibility to alter the interface between foot and pedal. The aim of this study was therefore to analyze plantar pressure distribution in carbon fiber foot orthoses in comparison to standard insoles of commercially available cycling shoes. Materials and Methods: 11 pain-free triathletes (Age: 29 +/- 9, 1.77 +/- 0.04 m, 68 5 kg) were tested on a cycle ergometer at 60 and 90 rotations per minute (rpm) at workloads of 200 and 300 Watts. Subjects wore in randomized order a cycling shoe with its standard insole (control condition CO) or the shoe with carbon fiber foot orthoses (Condition CA). Mean peak pressure out of 30 movement cycles were extracted for the total foot and specific foot regions (rear, mid, fore foot (medial, central, lateral) and toe region). Three-factor ANOVAs (factor foot orthoses, rpm, workload) for repeated measures (alpha = 0.05) were used to analyze the main question of a foot orthoses effect on peak in-shoe plantar pressure. Results: Peak pressures in the total foot were in a range of 70-75 kPa for 200 Watts (W) (300 W: 85-110 kPa). The carbon fiber foot orthoses reduced peak pressures by -4,1\% compared to the standard insole (p = 0,10). In the foot regions rear(-16,6\%, p<0.001), mid (-20,0\%, p<0.001) and fore foot (-5.9\%, p < 0.03)CA reduced peak pressure compared to CO. In the toe region, peak pressure was higher in CA (+16,2\%) compared to CO (p<0,001). The lateral fore foot showed higher peak pressures in CA (+34\%) and CO (+59\%) compared to medial and central fore foot. Conclusion: Carbon fiber can serve as a suitable material for foot orthoses manufacturing in cycling. Plantar pressures do not increase due to the stiffness of the carbon. Individual customization may have the potential to reduce peak pressure in certain foot areas.}, language = {de} } @article{CarlsohnNippeHeydenreichetal.2012, author = {Carlsohn, Anja and Nippe, Susanne and Heydenreich, Juliane and Mayer, Frank}, title = {Carbohydrate intake and food sources of junior triathletes during a moderate and an intensive training period}, series = {International journal of sport nutrition and exercise metabolism}, volume = {22}, journal = {International journal of sport nutrition and exercise metabolism}, number = {6}, publisher = {Human Kinetics Publ.}, address = {Champaign}, issn = {1526-484X}, pages = {438 -- 443}, year = {2012}, abstract = {The study was conducted to investigate the quantity and the main food sources of carbohydrate (CHO) intake of junior elite triathletes during a short-term moderate (MOD; 12 km swimming, 100 km cycling, 30 km running per wk) and intensive training period (INT; 23 km swimming, 200 km cycling, 45 km running per wk). Self-reported dietary-intake data accompanied by training protocols of 7 male triathletes (18.1 +/- 2.4 yr, 20.9 +/- 1.4 kg/m(2)) were collected on 7 consecutive days during both training periods in the same competitive season. Total energy and CHO intake were calculated based on the German Food Database. A paired t test was applied to test for differences between the training phases (alpha = .05). CHO intake was slightly higher in INT than in MOD (9.0 +/- 1.6 g . kg(-1) . d(-1) vs. 7.8 +/- 1.6 g . kg(-1) . d(-1); p = .041). Additional CHO in INT was mainly ingested during breakfast (115 +/- 37 g in MOD vs. 175 +/- 23 g in INT; p = .002) and provided by beverages (280.5 +/- 97.3 g/d vs. 174.0 +/- 58.3 g/d CHO; p = .112). Altogether, main meals provided approximately two thirds of the total CHO intake. Pre- and postexercise snacks additionally supplied remarkable amounts of CHO (198.3 +/- 84.3 g/d in INT vs. 185.9 +/- 112 g/d CHO in MOD; p = .231). In conclusion, male German junior triathletes consume CHO in amounts currently recommended for endurance athletes during moderate to intensive training periods. Main meals provide the majority of CHO and should therefore not be skipped. CHO-containing beverages, as well as pre- and postexercise snacks, may provide a substantial amount of CHO intake in training periods with high CHO requirements.}, language = {en} } @article{CarlsohnScharhagRosenbergerSchappetal.2012, author = {Carlsohn, Anja and Scharhag-Rosenberger, Friederike and Schapp, Lukas and Fusch, Gerhard and Mayer, Frank}, title = {Validity of the determination of energy input from a dietary record in persons of normal weight - dependence on the level of energy input comparison between elite sportsmen with very high energy intake and a control group of persons of normal weight}, series = {Ern{\"a}hrungs-Umschau : Forschung \& Praxis}, volume = {59}, journal = {Ern{\"a}hrungs-Umschau : Forschung \& Praxis}, number = {10}, publisher = {Umschau-Zeitschriftenverl.}, address = {Frankfurt, Main}, issn = {0174-0008}, doi = {10.4455/eu.2012.958}, pages = {572 -- 577}, year = {2012}, abstract = {Dietary records are often biased, especially those of overweight individuals. The purpose of the study was to investigate underreporting among persons of normal weight with a very high energy intake (El). The total energy expenditure (TEE) of 16 elite athletes (BMI 24 +/- 2 kg/m(2)) and 17 controls (BMI 23 3 kg/m2) was measured using the doubly-labeled water technique (DLW, 14d). El was estimated using 2 x 3-day dietary records. Underreporters were identified by BLACK'S cut-off (El:TEE < 0.76). 44\% of athletes (El: 3584 824 kcal/d; TEE: 4621 1460 kcal/d) and 29\% of controls (El: 2552 680 kcal/d; TEE: 3151 822 kcal/d) were identified as underreporters. TEE explains 52\% of underreporting. In summary, a high energy intake seems to strongly predict underreporting. Prevalence and magnitude of underreporting increase with increasing energy intake.}, language = {de} } @inproceedings{CarlsohnWeberMuelleretal.2012, author = {Carlsohn, Anja and Weber, Josefine and M{\"u}ller, Juliane and Stuwe, Anja and M{\"u}ller, Steffen and Mayer, Frank}, title = {Dietary intake to reduce body mass before competition in german judo athletes}, series = {Medicine and science in sports and exercise : official journal of the American College of Sports Medicine}, volume = {44}, booktitle = {Medicine and science in sports and exercise : official journal of the American College of Sports Medicine}, publisher = {Lippincott Williams \& Wilkins}, address = {Philadelphia}, issn = {0195-9131}, pages = {109 -- 109}, year = {2012}, language = {en} } @article{CasselMuellerCarlsohnetal.2012, author = {Cassel, Michael and M{\"u}ller, Steffen and Carlsohn, Anja and Baur, Heiner and Jerusel, N. and Mayer, Frank}, title = {Intra- and interrater variability of sonographic investigations of patella and achilles tendons}, series = {Sportverletzung, Sportschaden : Grundlagen, Pr{\"a}vention, Rehabilitation}, volume = {26}, journal = {Sportverletzung, Sportschaden : Grundlagen, Pr{\"a}vention, Rehabilitation}, number = {1}, publisher = {Thieme}, address = {Stuttgart}, issn = {0932-0555}, doi = {10.1055/s-0031-1281839}, pages = {21 -- 26}, year = {2012}, abstract = {Background: Clinical examinations of tendon disorders routinely include ultrasound examinations, despite the fact that availability of data concerning validity criteria of these measurements are limited. The present study therefore aims to evaluate the reliability of measurements of Achilles- and Patella tendon diameter and in the detection of structural adaptations. Materials and Methods: In 14 healthy, recreationally active subjects both asymptomatic Achilles (AT) and patella tendons (PT) were measured twice by two examiners in a test-retest design. Besides the detection of anteroposterior (a.p.-) and mediolateral (m.l.-) diameters, areas of hypoechogenicity and neovascularisation were registered. Data were analysed descriptively with calculation of test-retest variability (TRV), intraclass-correlation coefficient (ICC) and Bland and Altman's plots with bias and 95\% limits of agreement (LOA). Results: Intra- and interrater differences of AT- and PT-a.p.-diameter varied from 0.2 - 1.2 mm, those of AT- and PT-m.l-diameter from 0.7-5.1 mm. Areas of hypoechogenicity were visible in 24\% of the tendons, while 15\% showed neovascularisations. Intrarater AT-a.p.-diameters showed sparse deviations (TRV 4.5-7.4\%; ICC 0.60-0.84; bias -0.05-0.07 mm; LOA-0.6-0.5 to -1.1 - 1.0 mm), while interrater AT- and PT-m.l.-diameters were highly variable (TRV 13.7-19.7\%; ICC 0.11-0.20; bias -1.4-4.3 mm; LOA-5.5-2.7 to -10.5 - 1.9 mm). Conclusion: Our results suggest that the measurement of AT- and PT-a.p.-diameters is a reliable parameter. In contrast, reproducibility of AT- and PT-m.l.-diameters is questionable. The study corroborates the presence of hypoechogenicity and neovascularisation in asymptomatic tendons.}, language = {de} } @inproceedings{HeydenreichCarlsohnLinneetal.2012, author = {Heydenreich, Juliane and Carlsohn, Anja and Linne, Karsten and Mayer, Frank}, title = {Micronutrient intake in young athletes}, series = {Medicine and science in sports and exercise : official journal of the American College of Sports Medicine}, volume = {44}, booktitle = {Medicine and science in sports and exercise : official journal of the American College of Sports Medicine}, number = {1}, publisher = {Lippincott Williams \& Wilkins}, address = {Philadelphia}, issn = {0195-9131}, pages = {951 -- 951}, year = {2012}, language = {en} } @inproceedings{IntziegianniCasselMuelleretal.2012, author = {Intziegianni, Konstantina and Cassel, Michael and M{\"u}ller, Steffen and Mayer, Frank}, title = {Ultrasound evaluation of the patellar tendon cross-sectional area and its relation to maximum force}, series = {Medicine and science in sports and exercise : official journal of the American College of Sports Medicine}, volume = {44}, booktitle = {Medicine and science in sports and exercise : official journal of the American College of Sports Medicine}, publisher = {Lippincott Williams \& Wilkins}, address = {Philadelphia}, issn = {0195-9131}, pages = {714 -- 714}, year = {2012}, language = {en} } @inproceedings{KoenigStollMayeretal.2012, author = {K{\"o}nig, Niklas and Stoll, Andreas and Mayer, Frank and Baur, Heiner}, title = {Intrasession reliability of insole in-shoe plantar pressure measurements in different foot areas}, series = {Medicine and science in sports and exercise : official journal of the American College of Sports Medicine}, volume = {44}, booktitle = {Medicine and science in sports and exercise : official journal of the American College of Sports Medicine}, publisher = {Lippincott Williams \& Wilkins}, address = {Philadelphia}, issn = {0195-9131}, pages = {941 -- 941}, year = {2012}, language = {en} } @unpublished{Mayer2012, author = {Mayer, Frank}, title = {Frequency of sport injuries and stress-related conditions in top-class Sport}, series = {Der Orthop{\"a}de}, volume = {41}, journal = {Der Orthop{\"a}de}, number = {7}, publisher = {Springer}, address = {New York}, issn = {0085-4530}, doi = {10.1007/s00132-012-1971-2}, pages = {560 -- 560}, year = {2012}, language = {de} }