@article{WojcinskiDupontSchmidtetal.2012, author = {Wojcinski, Sebastian and Dupont, Jennifer and Schmidt, Werner and Cassel, Michael and Hillemanns, Peter}, title = {Real-time ultrasound elastography in 180 axillary lymph nodes elasticity distribution in healthy lymph nodes and prediction of breast cancer metastases}, series = {BMC medical imaging}, volume = {12}, journal = {BMC medical imaging}, publisher = {BioMed Central}, address = {London}, issn = {1471-2342}, doi = {10.1186/1471-2342-12-35}, pages = {10}, year = {2012}, abstract = {Background: To determine the general appearance of normal axillary lymph nodes (LNs) in real-time tissue sonoelastography and to explore the method's potential value in the prediction of LN metastases. Methods: Axillary LNs in healthy probands (n=165) and metastatic LNs in breast cancer patients (n=15) were examined with palpation, B-mode ultrasound, Doppler and sonoelastography (assessment of the elasticity of the cortex and the medulla). The elasticity distributions were compared and sensitivity (SE) and specificity (SP) were calculated. In an exploratory analysis, positive and negative predictive values (PPV, NPV) were calculated based upon the estimated prevalence of LN metastases in different risk groups. Results: In the elastogram, the LN cortex was significantly harder than the medulla in both healthy (p=0.004) and metastatic LNs (p=0.005). Comparing healthy and metastatic LNs, there was no difference in the elasticity distribution of the medulla (p=0.281), but we found a significantly harder cortex in metastatic LNs (p=0.006). The SE of clinical examination, B-mode ultrasound, Doppler ultrasound and sonoelastography was revealed to be 13.3\%, 40.0\%, 14.3\% and 60.0\%, respectively, and SP was 88.4\%, 96.8\%, 95.6\% and 79.6\%, respectively. The highest SE was achieved by the disjunctive combination of B-mode and elastographic features (cortex >3mm in B-mode or blue cortex in the elastogram, SE=73.3\%). The highest SP was achieved by the conjunctive combination of B-mode ultrasound and elastography (cortex >3mm in B-mode and blue cortex in the elastogram, SP=99.3\%). Conclusions: Sonoelastography is a feasible method to visualize the elasticity distribution of LNs. Moreover, sonoelastography is capable of detecting elasticity differences between the cortex and medulla, and between metastatic and healthy LNs. Therefore, sonoelastography yields additional information about axillary LN status and can improve the PPV, although this method is still experimental.}, language = {en} } @misc{WojcinskiDupontSchmidtetal.2012, author = {Wojcinski, Sebastian and Dupont, Jennifer and Schmidt, Werner and Cassel, Michael and Hillemanns, Peter}, title = {Real-time ultrasound elastography in 180 axillary lymph nodes}, series = {Postprints der Universit{\"a}t Potsdam : Humanwissenschaftliche Reihe}, journal = {Postprints der Universit{\"a}t Potsdam : Humanwissenschaftliche Reihe}, number = {626}, issn = {1866-8364}, doi = {10.25932/publishup-43158}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus4-431584}, pages = {12}, year = {2012}, abstract = {Background To determine the general appearance of normal axillary lymph nodes (LNs) in real-time tissue sonoelastography and to explore the method′s potential value in the prediction of LN metastases. Methods Axillary LNs in healthy probands (n=165) and metastatic LNs in breast cancer patients (n=15) were examined with palpation, B-mode ultrasound, Doppler and sonoelastography (assessment of the elasticity of the cortex and the medulla). The elasticity distributions were compared and sensitivity (SE) and specificity (SP) were calculated. In an exploratory analysis, positive and negative predictive values (PPV, NPV) were calculated based upon the estimated prevalence of LN metastases in different risk groups. Results In the elastogram, the LN cortex was significantly harder than the medulla in both healthy (p=0.004) and metastatic LNs (p=0.005). Comparing healthy and metastatic LNs, there was no difference in the elasticity distribution of the medulla (p=0.281), but we found a significantly harder cortex in metastatic LNs (p=0.006). The SE of clinical examination, B-mode ultrasound, Doppler ultrasound and sonoelastography was revealed to be 13.3\%, 40.0\%, 14.3\% and 60.0\%, respectively, and SP was 88.4\%, 96.8\%, 95.6\% and 79.6\%, respectively. The highest SE was achieved by the disjunctive combination of B-mode and elastographic features (cortex >3mm in B-mode or blue cortex in the elastogram, SE=73.3\%). The highest SP was achieved by the conjunctive combination of B-mode ultrasound and elastography (cortex >3mm in B-mode and blue cortex in the elastogram, SP=99.3\%). Conclusions Sonoelastography is a feasible method to visualize the elasticity distribution of LNs. Moreover, sonoelastography is capable of detecting elasticity differences between the cortex and medulla, and between metastatic and healthy LNs. Therefore, sonoelastography yields additional information about axillary LN status and can improve the PPV, although this method is still experimental.}, language = {en} } @article{WojcinskiCasselFarrokhetal.2012, author = {Wojcinski, Sebastian and Cassel, Michael and Farrokh, Andre and Soliman, Amr A. and Hille, Ursula and Schmidt, Werner and Degenhardt, Friedrich and Hillemanns, Peter}, title = {Variations in the elasticity of breast tissue during the menstrual cycle determined by real-time sonoelastography}, series = {Journal of ultrasound in medicine}, volume = {31}, journal = {Journal of ultrasound in medicine}, number = {1}, publisher = {American Institute of Ultrasound in Medicine}, address = {Laurel}, issn = {0278-4297}, pages = {63 -- 72}, year = {2012}, abstract = {Objectives-The purpose of this study was to determine the dependence of breast tissue elasticity on the menstrual cycle of healthy volunteers by means of real-time sonoelastography. Methods-Twenty-two healthy volunteers (aged 18-33 years) were examined once weekly during two consecutive menstrual cycles using sonoelastography. Group 1 (n = 10) was not taking hormonal medication; group 2 (n = 12) was taking oral contraceptives. Results-The breast parenchyma appeared softer than the dermis and harder than the adipose tissue, and elasticity varied over the menstrual cycle and between groups. Group 1 (no hormone intake) showed continuously increasing elasticity with relatively soft breast parenchyma in the menstrual and follicular phases and harder parenchyma in the luteal phase (P = .012). Group 2 (oral contraceptives) showed no statistically significant changes in breast parenchymal elasticity according to sonoelastography. The parenchyma was generally softer in group 1 compared with group 2 throughout the menstrual cycle (P = .033). The dermis, the subcutaneous adipose tissue, and the pectoralis major muscle showed no changes in elasticity. Comparison of measurements made during the first and the second menstrual cycles showed similar patterns of elasticity in both groups. Conclusions-Sonoelastography is a reproducible method that can be used to determine the dependence of breast parenchyma elasticity on the menstrual cycle and on the intake of hormonal contraceptives.}, language = {en} } @inproceedings{WochatzCasselKoenigetal.2013, author = {Wochatz, Monique and Cassel, Michael and K{\"o}nig, Niklas and Fr{\"o}hlich, Katja and Mayer, Frank}, title = {Intra- and inter-observer variability of a retrospective analysis of achilles tendon ultrasound scans}, series = {Medicine and science in sports and exercise : official journal of the American College of Sports Medicine}, volume = {45}, booktitle = {Medicine and science in sports and exercise : official journal of the American College of Sports Medicine}, number = {5}, publisher = {Lippincott Williams \& Wilkins}, address = {Philadelphia}, issn = {0195-9131}, pages = {239 -- 239}, year = {2013}, language = {en} } @misc{WahmkowCasselMayeretal.2017, author = {Wahmkow, Gunnar and Cassel, Michael and Mayer, Frank and Baur, Heiner}, title = {Effects of different medial arch support heights on rearfoot kinematics}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus4-402934}, pages = {11}, year = {2017}, abstract = {Background Foot orthoses are usually assumed to be effective by optimizing mechanically dynamic rearfoot configuration. However, the effect from a foot orthosis on kinematics that has been demonstrated scientifically has only been marginal. The aim of this study was to examine the effect of different heights in medial arch-supported foot orthoses on rear foot motion during gait. Methods Nineteen asymptomatic runners (36±11years, 180±5cm, 79±10kg; 41±22km/week) participated in the study. Trials were recorded at 3.1 mph (5 km/h) on a treadmill. Athletes walked barefoot and with 4 different not customized medial arch-supported foot orthoses of various arch heights (N:0 mm, M:30 mm, H:35 mm, E:40mm). Six infrared cameras and the `Oxford Foot Model´ were used to capture motion. The average stride in each condition was calculated from 50 gait cycles per condition. Eversion excursion and internal tibia rotation were analyzed. Descriptive statistics included calculating the mean ± SD and 95\% CIs. Group differences by condition were analyzed by one factor (foot orthoses) repeated measures ANOVA (α = 0.05). Results Eversion excursion revealed the lowest values for N and highest for H (B:4.6°±2.2°; 95\% CI [3.1;6.2]/N:4.0°±1.7°; [2.9;5.2]/M:5.2°±2.6°; [3.6;6.8]/H:6.2°±3.3°; [4.0;8.5]/E:5.1°±3.5°; [2.8;7.5]) (p>0.05). Range of internal tibia rotation was lowest with orthosis H and highest with E (B:13.3°±3.2°; 95\% CI [11.0;15.6]/N:14.5°±7.2°; [9.2;19.6]/M:13.8°±5.0°; [10.8;16.8]/H:12.3°±4.3°; [9.0;15.6]/E:14.9°±5.0°; [11.5;18.3]) (p>0.05). Differences between conditions were small and the intrasubject variation high. Conclusion Our results indicate that different arch support heights have no systematic effect on eversion excursion or the range of internal tibia rotation and therefore might not exert a crucial influence on rear foot alignment during gait.}, language = {en} } @article{WahmkowCasselMayeretal.2017, author = {Wahmkow, Gunnar and Cassel, Michael and Mayer, Frank and Baur, Heiner}, title = {Effects of different medial arch support heights on rearfoot kinematics}, series = {PLoS one}, volume = {12}, journal = {PLoS one}, number = {3}, publisher = {PLoS}, address = {Lawrence, Kan.}, issn = {1932-6203}, doi = {10.1371/journal.pone.0172334}, year = {2017}, abstract = {Background Foot orthoses are usually assumed to be effective by optimizing mechanically dynamic rearfoot configuration. However, the effect from a foot orthosis on kinematics that has been demonstrated scientifically has only been marginal. The aim of this study was to examine the effect of different heights in medial arch-supported foot orthoses on rear foot motion during gait. Methods Nineteen asymptomatic runners (36±11years, 180±5cm, 79±10kg; 41±22km/week) participated in the study. Trials were recorded at 3.1 mph (5 km/h) on a treadmill. Athletes walked barefoot and with 4 different not customized medial arch-supported foot orthoses of various arch heights (N:0 mm, M:30 mm, H:35 mm, E:40mm). Six infrared cameras and the `Oxford Foot Model´ were used to capture motion. The average stride in each condition was calculated from 50 gait cycles per condition. Eversion excursion and internal tibia rotation were analyzed. Descriptive statistics included calculating the mean ± SD and 95\% CIs. Group differences by condition were analyzed by one factor (foot orthoses) repeated measures ANOVA (α = 0.05). Results Eversion excursion revealed the lowest values for N and highest for H (B:4.6°±2.2°; 95\% CI [3.1;6.2]/N:4.0°±1.7°; [2.9;5.2]/M:5.2°±2.6°; [3.6;6.8]/H:6.2°±3.3°; [4.0;8.5]/E:5.1°±3.5°; [2.8;7.5]) (p>0.05). Range of internal tibia rotation was lowest with orthosis H and highest with E (B:13.3°±3.2°; 95\% CI [11.0;15.6]/N:14.5°±7.2°; [9.2;19.6]/M:13.8°±5.0°; [10.8;16.8]/H:12.3°±4.3°; [9.0;15.6]/E:14.9°±5.0°; [11.5;18.3]) (p>0.05). Differences between conditions were small and the intrasubject variation high. Conclusion Our results indicate that different arch support heights have no systematic effect on eversion excursion or the range of internal tibia rotation and therefore might not exert a crucial influence on rear foot alignment during gait.}, language = {en} } @article{ScharhagRosenbergerWochatzOttoetal.2014, author = {Scharhag-Rosenberger, Friederike and Wochatz, Monique and Otto, Christoph and Cassel, Michael and Mayer, Frank and Scharhag, J{\"u}rgen}, title = {Blood lactate concentrations are mildly affected by mobile gas exchange measurements}, series = {International journal of sports medicine}, volume = {35}, journal = {International journal of sports medicine}, number = {7}, publisher = {Thieme}, address = {Stuttgart}, issn = {0172-4622}, doi = {10.1055/s-0033-1354386}, pages = {590 -- 594}, year = {2014}, abstract = {We sought to investigate the effects of wearing a mobile respiratory gas analysis system during a treadmill test on blood lactate (bLa) concentrations and commonly applied bLa thresholds. A total of 16 recreational athletes (31 +/- 3 years, V0205: 58 6 ml min(-1)-kg(-1)) performed one multistage treadmill test with and one without gas exchange measurements (GEM and noGEM). The whole bLa curve, the lactate threshold (LT), the individual anaerobic thresholds according to Stegmann(IAT(sr)) and Dickhuth (IAT(Di)), and a fixed bLa concentration of 4 mmob.l(-1) (OBLA) were evaluated. The bLa curve was shifted slightly leftward in GEM compared to noGEM (P<0.05), whereas the heart rate response was not different between conditions (P= 0.89). There was no difference between GEM and noGEM for LT (2.61 +/- 0.34 vs. 2.64 +/- 0.39 m(-1) s(-1) P=0.49) and IAT(st) (3.47 +/- 0.42 vs. 3.55 +/- 0.47m-s(-1), P=0.12). However, IATD(Di) (3.57 +/- 0.39 vs. 3.66 +/- 0.44m-s(-1), P<0.01) and OBLA (3.85 +/- 0.46 vs. 3.96 +/- 0.47m-s-1, P<0.01) occurred at slower running velocities in GEM. The bLa response to treadmill tests is mildly affected by wearing a mobile gas analysis system. This also applies to bLa thresholds located at higher exercise intensities. While the magnitude of the effects is of little importance for recreational athletes, it might be relevant for elite athletes and scientific studies.}, language = {en} } @article{ScharhagRosenbergerCarlsohnCasseletal.2011, author = {Scharhag-Rosenberger, Friederike and Carlsohn, Anja and Cassel, Michael and Mayer, Frank and Scharhag, J{\"u}rgen}, title = {How to test maximal oxygen uptake a study on timing and testing procedure of a supramaximal verification test}, series = {Applied physiology, nutrition, and metabolism = Physiologie appliqu{\´e}e, nutrition et m{\´e}tabolisme}, volume = {36}, journal = {Applied physiology, nutrition, and metabolism = Physiologie appliqu{\´e}e, nutrition et m{\´e}tabolisme}, number = {1}, publisher = {NRC Research Press}, address = {Ottawa}, issn = {1715-5312}, doi = {10.1139/H10-099}, pages = {153 -- 160}, year = {2011}, abstract = {On utilise de plus en plus les tests de verification pour confirmer l'atteinte du consommation d'oxygene maximale (VO(2 max)). Toutefois, le moment et les methodes d'evaluation varient d'un groupe de travail a l'autre. Les objectifs de cette etude sont de constater si on peut administrer un test de verification apres un test d'effort progressif ou s'il est preferable de le faire une autre journee et si on peut determiner le VO(2 max) tout de meme lors de la premiere seance chez des sujets ne repondant pas au critere de verification. Quarante sujets (age, 24 +/- 4 ans; VO(2 max), 50 +/- 7 mL center dot min(-1)center dot kg(-1)) participent a un test d'effort progressif sur tapis roulant et, 10 min plus tard, a un test de verification (VerifDay1) a 110 \% de la velocite maximale (v(max)). Le critere de verification est un VO(2) de pointe au VerifDay1 < 5,5 \% a la valeur retenue au test d'effort progressif. Les sujets ne repondant pas au critere de verification passent un autre test de verification, mais a 115 \% du VerifDay1', et ce, 10 min plus tard pour confirmer le VO(2) de pointe du VerifDay1 en tant que VO(2 max). Tous les autres sujets repassent le VerifDay1 a un jour different (VerifDay2). Six sujets sur quarante ne repondent pas au critere de verification. Chez quatre d'entre eux, on confirme l'atteinte du VO(2 max) au VerifDay1'. Le VO(2) de pointe au VerifDay1 est equivalent a celui du VerifDay2 (3722 +/- 991 mL center dot min(-1) comparativement a 3752 +/- 995 mL center dot min(-1), p = 0,56), mais le temps jusqu'a l'epuisement est significativement plus long au VerifDay2 (2:06 +/- 0:22 min:s comparativement a 2:42 +/- 0:38 min:s, p < 0,001, n = 34). Le VO(2) de pointe obtenu au test de verification ne semble pas conditionne par un test d'effort progressif maximal prealable. On peut donc realiser le test d'effort progressif et le test de verification lors de la meme seance d'evaluation. Chez presque tous les individus ne repondant pas au critere de verification, on peut determiner le VO(2 max) au moyen d'un autre test de verification plus intense.}, language = {en} } @article{RischWochatzMesserschmidtetal.2017, author = {Risch, Lucie and Wochatz, Monique and Messerschmidt, Janin and Engel, Tilman and Mayer, Frank and Cassel, Michael}, title = {Reliability of evaluating achilles tendon vascularization assessed with doppler ultrasound advanced dynamic flow}, series = {Journal of ultrasound in medicine}, volume = {37}, journal = {Journal of ultrasound in medicine}, number = {3}, publisher = {Wiley}, address = {Hoboken}, issn = {0278-4297}, doi = {10.1002/jum.14414}, pages = {737 -- 744}, year = {2017}, abstract = {The reliability of quantifying intratendinous vascularization by high-sensitivity Doppler ultrasound advanced dynamic flow has not been examined yet. Therefore, this study aimed to investigate the intraobserver and interobserver reliability of evaluating Achilles tendon vascularization by advanced dynamic flow using established scoring systems. Methods-Three investigators evaluated vascularization in 67 recordings in a test-retest design, applying the Ohberg score, a modified Ohberg score, and a counting score. Intraobserver and interobserver agreement for the Ohberg score and modified Ohberg score was analyzed by the Cohen kappa and Fleiss kappa coefficients (absolute), Kendall tau b coefficient, and Kendall coefficient of concordance (W; relative). The reliability of the counting score was analyzed by intraclass correlation coefficients (ICC) 2.1 and 3.1, the standard error of measurement (SEM), and Bland-Altman analysis (bias and limits of agreement [LoA]). Results-Intraobserver and interobserver agreement (absolute/relative) ranged from 0.61 to 0.87/0.87 to 0.95 and 0.11 to 0.66/0.76 to 0.89 for the Ohberg score and from 0.81 to 0.87/0.92 to 0.95 and 0.64 to 0.80/0.88 to 0.93 for the modified Ohberg score, respectively. The counting score revealed an intraobserver ICC of 0.94 to 0.97 (SEM, 1.0-1.5; bias, -1; and LoA, 3-4 vessels). The interobserver ICC for the counting score ranged from 0.91 to 0.98 (SEM, 1.0-1.9; bias, 0; and LoA, 3-5 vessels). Conclusions-The modified Ohberg score and counting score showed excellent reliability and seem convenient for research and clinical practice. The Ohberg score revealed decent intraobserver but unexpected low interobserver reliability and therefore cannot be recommended.}, language = {en} } @article{RischStollSchomoelleretal.2020, author = {Risch, Lucie and Stoll, Josefine and Schom{\"o}ller, Anne and Engel, Tilman and Mayer, Frank and Cassel, Michael}, title = {Intraindividual Doppler Flow Response to Exercise Differs Between Symptomatic and Asymptomatic Achilles Tendons}, series = {Frontiers in physiology}, volume = {12}, journal = {Frontiers in physiology}, publisher = {Frontiers Research Foundation}, address = {Lausanne, Schweiz}, issn = {1664-042X}, doi = {10.3389/fphys.2021.617497}, pages = {1 -- 8}, year = {2020}, abstract = {Objective: This study investigated intraindividual differences of intratendinous blood flow (IBF) in response to running exercise in participants with Achilles tendinopathy. Design: This is a cross-sectional study. Setting: The study was conducted at the University Outpatient Clinic. Participants: Sonographic detectable intratendinous blood flow was examined in symptomatic and contralateral asymptomatic Achilles tendons of 19 participants (42 ± 13 years, 178 ± 10 cm, 76 ± 12 kg, VISA-A 75 ± 16) with clinically diagnosed unilateral Achilles tendinopathy and sonographic evident tendinosis. Intervention: IBF was assessed using Doppler ultrasound "Advanced Dynamic Flow" before (Upre) and 5, 30, 60, and 120 min (U5-U120) after a standardized submaximal constant load run. Main Outcome Measure: IBF was quantified by counting the number (n) of vessels in each tendon. Results: At Upre, IBF was higher in symptomatic compared with asymptomatic tendons [mean 6.3 (95\% CI: 2.8-9.9) and 1.7 (0.4-2.9), p < 0.01]. Overall, 63\% of symptomatic and 47\% of asymptomatic Achilles tendons responded to exercise, whereas 16 and 11\% showed persisting IBF and 21 and 42\% remained avascular throughout the investigation. At U5, IBF increased in both symptomatic and asymptomatic tendons [difference to baseline: 2.4 (0.3-4.5) and 0.9 (0.5-1.4), p = 0.05]. At U30 to U120, IBF was still increased in symptomatic but not in asymptomatic tendons [mean difference to baseline: 1.9 (0.8-2.9) and 0.1 (-0.9 to 1.2), p < 0.01]. Conclusion: Irrespective of pathology, 47-63\% of Achilles tendons responded to exercise with an immediate acute physiological IBF increase by an average of one to two vessels ("responders"). A higher amount of baseline IBF (approximately five vessels) and a prolonged exercise-induced IBF response found in symptomatic ATs indicate a pain-associated altered intratendinous "neovascularization."}, language = {en} }